Power modulations in new phacoemulsification technology: Improved outcomes

被引:59
作者
Fine, IH
Packer, M
Hoffman, RS
机构
[1] Oregon Eye Inst, Eugene, OR 97401 USA
[2] Oregon Hlth & Sci Univ, Portland, OR USA
关键词
D O I
10.1016/j.jcrs.2003.09.062
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose., To evaluate the clinical outcomes of new phacoemulsification technology. Setting: Oregon Eye Institute, Eugene, Oregon, USA. Methods: After optimization of surgical parameters, patients were randomly assigned to cataract extraction with 1 of 4 phacoemulsification machines using new technology available within the past 1 to 2 years. Outcomes were compared with previously published results for these same machines obtained before the advent of the new technology. Results: Improvements in effective phaco time, average phaco power, percentage of clear corneas, and 20/40 or better uncorrected visual acuity at the first postoperative visit were noted for most systems using new technology. Conclusion: New phacoemulsification technology offers surgical advantages that translate into improved clinical outcomes.
引用
收藏
页码:1014 / 1019
页数:6
相关论文
共 9 条
[1]   Dispersive-cohesive viscoelastic soft shell technique [J].
Arshinoff, SA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02) :167-173
[2]  
Fine I. H., 1998, OPERATIVE TECH CATAR, V1, P61
[3]  
Fine IH, 2002, DEV OPHTHALMOL, V34, P32
[4]   New phacoemulsification technologies [J].
Fine, IH ;
Packer, M ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (06) :1054-1060
[5]   Use of power modulations in phacoemulsification - Choo-choo chop and flip phacoemulsification [J].
Fine, IH ;
Packer, M ;
Hoffman, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02) :188-197
[6]  
GILLS JP, 2003, COMPLETE SURG GUIDE
[7]   Comparison of sonic and ultrasonic phacoemulsification using the Staar Sonic Wave system [J].
Hoffman, RS ;
Fine, IH ;
Packer, M ;
Brown, LK .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1581-1584
[8]   Immersion A-scan compared with partial coherence interferometry - Outcomes analysis [J].
Packer, M ;
Fine, IH ;
Hoffman, RS ;
Coffman, PG ;
Brown, LK .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :239-242
[9]  
Seibel BS., 1999, PHACODYNAMICS MASTER, P98