Detailed Investigations on a Multisection Cavity for a Continuously Frequency-Tunable Gyrotron

被引:10
作者
Liu, Diwei [1 ,2 ]
Song, Tao [1 ,2 ]
Hu, Qiao [1 ,2 ]
Huang, Jie [1 ,2 ]
Zhang, Yanqing [1 ,2 ]
Zhang, Chen [1 ,2 ]
Wang, Wei [1 ,2 ]
Hu, Min [1 ,2 ]
机构
[1] Univ Elect Sci & Technol China, Terahertz Sci & Technol Res Ctr, Chengdu 610054, Sichuan, Peoples R China
[2] Minist Educ, Key Lab THz Technol, Chengdu 610054, Sichuan, Peoples R China
关键词
Diffractive quality factor; frequency-tunable gyrotron; gyrotron cavity; starting current; NMR-SPECTROSCOPY; OPERATION;
D O I
10.1109/TED.2019.2909067
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of the slightly up-tapered sections in a multisection gyrotron cavity on the resonant frequency and the quality factor are investigated in detail. The main role of these sections is to change the effective cavity length or the total reflection. The slightly up-tapered section near the input section plays a role of increasing the effective cavity length and the diffractive quality factor, and the increase for a higher order axial mode is more obvious. The slightly up-tapered main section plays a role of reducing the diffractive quality factor, and the decrease for a lower order axial mode is more notable. The role of the slightly up-tapered section near the output end is complicated; when the angle is small, the main role of this section is to increase the effective cavity length; however, with the increase of the angle, the main role is to reduce the reflection from the open end. In a conventional three-section gyrotron cavity, the quality factor of the low-order axial mode is dozens of times of that of the high-order axial mode, and in an optimized multisection gyrotron cavity, the quality factor for all axial modes can maintain an order of magnitude in the cold cavity approximation; it means that the operating current for all axial modes can keep an order of magnitude.
引用
收藏
页码:2746 / 2751
页数:6
相关论文
共 20 条
[1]   High-resolution proton-detected NMR of proteins at very fast MAS [J].
Andreas, Loren B. ;
Le Marchand, Tanguy ;
Jaudzems, Kristaps ;
Pintacuda, Guido .
JOURNAL OF MAGNETIC RESONANCE, 2015, 253 :36-49
[2]   GENERALIZED NONLINEAR HARMONIC GYROTRON THEORY [J].
DANLY, BG ;
TEMKIN, RJ .
PHYSICS OF FLUIDS, 1986, 29 (02) :561-567
[3]   Frequency Tunable Gyrotron FU CW VA for Measuring Hyperfine Split of Positronium [J].
Dumbrajs, Olgierd ;
Idehara, Toshitaka .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2010, 31 (11) :1265-1270
[4]   Applications of NMR spectroscopy to systems biochemistry [J].
Fan, Teresa W. -M. ;
Lane, Andrew N. .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2016, 92-93 :18-53
[5]   Polarization-enhanced NMR spectroscopy of biomolecules in frozen solution [J].
Hall, DA ;
Maus, DC ;
Gerfen, GJ ;
Inati, SJ ;
Becerra, LR ;
Dahlquist, FW ;
Griffin, RG .
SCIENCE, 1997, 276 (5314) :930-932
[6]   Second harmonic operation at 460 GHz and broadband continuous frequency tuning of a gyrotron oscillator [J].
Hornstein, MK ;
Bajaj, VS ;
Griffin, RG ;
Kreischer, KE ;
Mastovsky, I ;
Shapiro, MA ;
Sirigiri, JR ;
Temkin, RJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2005, 52 (05) :798-807
[7]   Study of a Coaxial Gyrotron Cavity With Improved Mode Selection [J].
Liu, Diwei ;
Wang, Wei ;
Qiao, Shen ;
Yan, Yang .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2013, 60 (12) :4248-4251
[8]  
LIU SG, 1987, REALISTIC ELECT, P110
[9]   The coaxial gyrotron with two electron beams. I. Linear theory and nonlinear theory [J].
Liu, Shenggang ;
Yuan, Xuesong ;
Fu, Wengjie ;
Yan, Yang ;
Zhang, Yaxin ;
Li, Hongfu ;
Zhong, Renbin .
PHYSICS OF PLASMAS, 2007, 14 (10)
[10]   The future of NMR-based metabolomics [J].
Markley, John L. ;
Bruschweiler, Rafael ;
Edison, Arthur S. ;
Eghbalnia, Hamid R. ;
Powers, Robert ;
Raftery, Daniel ;
Wishart, David S. .
CURRENT OPINION IN BIOTECHNOLOGY, 2017, 43 :34-40