Influence of Abutment Screw Design and Surface Coating on the Bending Flexural Strength of the Implant Set

被引:4
作者
do Prado, Celio Jesus [1 ]
das Neves, Flavio Domingues [1 ]
Soares, Carlos Jose [2 ]
Dantas, Kelly Abadia [1 ]
Dantas, Talita Souza [3 ]
Naves, Lucas Zago [4 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Occlus Fixed Prosthodont & Dent Mat, BR-38400 Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, BR-38400 Uberlandia, MG, Brazil
[3] Univ Fed Uberlandia, Sch Dent, Oral Rehabil Program, BR-38400 Uberlandia, MG, Brazil
[4] Univ Estadual Campinas, UNICAMP, Dept Restorat Dent, Dent Mat Div,Piracicaba Dent Sch, Piracicaba, SP, Brazil
关键词
dental implants; implant prosthesis; surface properties; solid lubrication; implant screw; OSSEOINTEGRATED DENTAL IMPLANTS; COMPLICATIONS; PRELOAD;
D O I
10.1563/AAID-JOI-D-11-00116
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to analyze the influence of the setting and the presence of solid lubricant on the abutment screw surface on the flexural strength of the joint implant/abutment/screw. Forty abutments were connected to external hex implants, divided into 4 groups (n = 10): FE (titanium alloy screw threaded in the extremity), LE (titanium alloy screw with solid lubricant and thread in the extremity), FT (titanium alloy screw with threaded in all its length), and LT (titanium alloy screw with solid lubricant and thread in all its length). Through the mechanical flexural test, the implant/abutment resistance was evaluated with load applied perpendicular to the long axis in a mechanical testing machine (EMIC) under a speed of 0.5 mm/min. Data were submitted to a statistics test, and results showed statistically significant differences between the FE group and the other groups, and the FE group showed the lowest values. The LE group showed greater values than the LT group, and the values were statistically significant. According to the methodology used, it can be concluded that within noncoated titanium screws, a screw threaded along its entire length provided greater rigidity to the implant set, while with the screw containing solid lubricant, the screw threaded in all its length provided less rigidity of the implant set than screws with the thread only on the end. Among screws with the same geometry, those with the solid lubricant are statistically higher than those which do not have threads just at the end, but those with threads along their entire length do not show statistically significant differences.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 22 条
  • [1] COMPARATIVE-STUDY OF ANTIROTATIONAL SINGLE TOOTH ABUTMENTS
    BALFOUR, A
    OBRIEN, GR
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (01) : 36 - 43
  • [2] Barbosa Gustavo Augusto Seabra, 2008, Braz. Dent. J., V19, P358, DOI 10.1590/S0103-64402008000400013
  • [3] Binon PP, 1996, INT J PROSTHODONT, V9, P149
  • [4] Tribological study of lubricious DLC biocompatible coatings
    Brizuela, M
    Garcia-Luis, A
    Viviente, JL
    Braceras, I
    Oñate, JI
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (12) : 1129 - 1133
  • [5] TIGHTENING CHARACTERISTICS FOR SCREWED JOINTS IN OSSEOINTEGRATED DENTAL IMPLANTS
    BURGUETE, RL
    JOHNS, RB
    KING, T
    PATTERSON, EA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) : 592 - 599
  • [6] The fit of cast and premachined implant abutments
    Byrne, D
    Houston, F
    Cleary, R
    Claffey, N
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (02) : 184 - 192
  • [7] Ekfeldt A, 1994, Int J Oral Maxillofac Implants, V9, P179
  • [8] BRANEMARK SINGLE TOOTH IMPLANTS - A PRELIMINARY-REPORT OF 76 IMPLANTS
    HAAS, R
    MENSDORFFPOUILLY, N
    MAILATH, G
    WATZEK, G
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (03) : 274 - 279
  • [9] Dynamic fatigue properties of the dental implant-abutment interface: Joint opening in wide-diameter versus standard-diameter hex-type implants
    Hoyer, SA
    Stanford, CM
    Buranadham, S
    Fridich, T
    Wagner, J
    Gratton, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (06) : 599 - 607
  • [10] Jorneus L, 1992, Int J Oral Maxillofac Implants, V7, P353