GSH Activated Biotin-tagged Near-Infrared Probe for Efficient Cancer Imaging

被引:33
|
作者
Guo, Ruiying [1 ]
Huang, Feng [1 ]
Zhang, Bo [2 ]
Yan, Youyou [2 ]
Che, Jinxin [1 ]
Jin, Yizhen [1 ]
Zhuang, Yuxin [1 ]
Dong, Rong [2 ]
Li, Yangling [2 ]
Tan, Biqin [2 ]
Song, Rui [3 ]
Hu, Yongzhou [1 ]
Dong, Xiaowu [1 ]
Li, Xin [1 ]
Lin, Nengming [2 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Hangzhou 310058, Zhejiang, Peoples R China
[2] Zhejiang Univ, Sch Med, Translat Med Res Ctr, Affiliated Hangzhou Peoples Hosp 1, Hangzhou 310006, Zhejiang, Peoples R China
[3] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Dept Pathol, Hangzhou 310009, Zhejiang, Peoples R China
来源
THERANOSTICS | 2019年 / 9卷 / 12期
基金
中国国家自然科学基金;
关键词
GSH activation; Near-Infrared (NIR) imaging; boundary recognition; In Vivo Imaging; histopathological analyses; INDOCYANINE GREEN; BREAST-CANCER; FLUORESCENT-PROBE; METHYLENE-BLUE; TUMOR; TIME; NANOPARTICLES; STATISTICS; DESIGN;
D O I
10.7150/thno.32742
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Tumor imaging tools with high specificity and sensitivity are needed to aid the boundary recognition in solid tumor diagnosis and surgical resection. In this study, we developed a near infra-red (NIR) probe (P6) for in vitro/in vivo tumor imaging on the basis of the dual strategy of cancer cell targeting and stimulus-dependent activation. The selective imaging capacity towards cancer cells of P6 was thoroughly investigated, and the potential mechanisms of endocytosis were preliminary explored. Methods: GSH-activated biotin labelled NIR probe (P6) was designed, synthesized and characterized. The GSH responsive properties were systematically illustrated through UV-vis, fluorescent tests and LC-MS analysis. In vitro fluorescent imaging of probe P6 was collected in various living cancer cell lines (i.e. SW480, HGC-27, H460, BxPC-3, KHOS) and normal cell lines (i.e. BEAS-2B, HLF-1, THP1) under confocal laser scanning microscopy. Probe P6 was further applied to image primary human cancer cells which were freshly isolated from the peritoneal carcinoma and rectal cancer patients. Serial sections of human tumor tissues were collected and sent for H&E (hematoxylin-eosin) staining and P6 imaging. Live fluorescent and photoacoustic imaging were used to investigate the in vivo imaging of P6 in both tumor and normal tissues in HGC 27 and KHOS xenograft model. Results: Probe P6 could be recognized and transported into cancer cells by tumor specific biotin receptors and efficiently be triggered by GSH to release fluorophore 4. In fact, the cellular uptake of P6 could be partially blocked by the addition of free biotin. Furthermore, probe P6 could image various cancer cell lines, as well as primary cancer cells, exhibiting a ten-fold increase in fluorescence intensity over normal cells. In freshly dissected cancer tissues, P6 fluorescent imaging distinguished the cancerous area under confocal laser scanning microscopy, which was exact the same area as indicated by H&E staining. We also found that P6 exhibited superior selectivity against cancer tissues by local injection. Conclusion: In this study, we developed a dual-modal NIR probe P6 with enhanced cellular uptake into cancer cells and environmental stimulus triggered fluorescence. Our strategy provided a novel insight into the development of imaging tools that could be potentially used for fluorescent image-guided cancer boundary recognition and possibly cancer diagnosis.
引用
收藏
页码:3515 / 3525
页数:11
相关论文
共 50 条
  • [21] Discovery of Butyrylcholinesterase-Activated Near-Infrared Fluorogenic Probe for Live-Cell and In Vivo Imaging
    Liu, Shi-Yu
    Xiong, Hao
    Yang, Jia-Qian
    Yang, Shu-Hou
    Li, Yingfu
    Yang, Wen-Chao
    Yang, Guang-Fu
    ACS SENSORS, 2018, 3 (10): : 2118 - 2128
  • [22] A Near-Infrared Cationic Photosensitizer for Lysosomal Activated Tumor Imaging and Photodynamic Therapy
    Li, Shining
    Jiang, Chao
    Huang, Yi
    Liu, Chuang
    Liu, Ruiyuan
    Qu, Jinqing
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (41) : 16604 - 16615
  • [23] Near-infrared photothermally activated nanomachines for cancer theragnosis
    He, Zhimei
    Zhu, Jun-Jie
    DALTON TRANSACTIONS, 2019, 48 (35) : 13120 - 13124
  • [24] Efficient Near-infrared AIE Nanoparticles for Cell Imaging
    Ji Guang
    Yan Lulin
    Wang Hui
    Ma Lian
    Xu Bin
    Tian Wenjing
    ACTA CHIMICA SINICA, 2016, 74 (11) : 917 - 922
  • [25] Near-infrared quantum dots for deep tissue imaging
    Aswathy, Ravindran Girija
    Yoshida, Yasuhiko
    Maekawa, T.
    Kumar, D. Sakthi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (04) : 1417 - 1435
  • [26] Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy
    Budner, Oliver
    Cwalinski, Tomasz
    Skokowski, Jaroslaw
    Marano, Luigi
    Resca, Luca
    Cwalina, Natalia
    Kalinowski, Leszek
    Hoveling, Richelle
    Roviello, Franco
    Polom, Karol
    CANCERS, 2022, 14 (07)
  • [27] Doxorubicin-loaded protease-activated near-infrared fluorescent polymeric nanoparticles for imaging and therapy of cancer
    Yildiz, Tugba
    Gu, Renpeng
    Zauscher, Stefan
    Betancourt, Tania
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2018, 13 : 6961 - 6986
  • [28] Near-Infrared Fluorescence Probe for Specific Detection of Acetylcholinesterase and Imaging in Live Cells and Zebrafish
    Fortibui, Maxine Mambo
    Jang, Mina
    Lee, Sohyun
    Ryoo, In-Ja
    Ahn, Jong Seog
    Ko, Sung-Kyun
    Kim, Jinheung
    ACS APPLIED BIO MATERIALS, 2022, 5 (05) : 2232 - 2239
  • [29] Micelle-based activatable probe for in vivo near-infrared optical imaging of cancer biomolecules
    Shimizu, Yoichi
    Temma, Takashi
    Hara, Isao
    Makino, Akira
    Yamahara, Ryo
    Ozeki, Ei-ichi
    Ono, Masahiro
    Saji, Hideo
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2014, 10 (01) : 187 - 195
  • [30] In vivo imaging of hypoxia generation stimulated by testosterone using a micelle-based near-infrared fluorescent probe
    Nan, Yanxia
    Zhou, Qiulan
    Zhao, Wenjie
    Lu, Yanbing
    Xu, Weijian
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 543 - 551