A Comparative Study of Poly(Azure A) Film-Modified Disposable Electrodes for Electrocatalytic Oxidation of H2O2: Effect of Doping Anion

被引:10
作者
Agrisuelas, Jeronimo [1 ,2 ]
Gonzalez-Sanchez, Maria-Isabel [1 ]
Gomez-Monedero, Beatriz [1 ]
Valero, Edelmira [1 ]
机构
[1] Univ Castilla La Mancha, Sch Ind Engn, Dept Phys Chem, Campus Univ S-N, Albacete 02071, Spain
[2] Univ Valencia, Fac Chem, Dept Phys Chem, C Dr Moliner 50, E-46100 Burjassot, Spain
关键词
conducting polymers; poly(azure A); sodium dodecyl sulfate; electrochemical sensor; disposable screen-printed electrodes; hydrogen peroxide; SCREEN-PRINTED ELECTRODES; SODIUM DODECYL-SULFATE; NICOTINAMIDE ADENINE-DINUCLEOTIDE; INJECTION ANALYSIS SYSTEM; WALLED-CARBON NANOTUBES; FAD HYBRID FILM; HYDROGEN-PEROXIDE; CONDUCTING POLYMERS; ELECTROCHEMICAL METHOD; POLY(NEUTRAL RED);
D O I
10.3390/polym10010048
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
In the present paper, poly(azure A) (PAA) films were electrosynthetized in the presence of different doping anions on disposable screen-printed carbon electrodes (SPCEs). The anions used included inorganic monoatomic (chloride and fluoride), inorganic polyatomic (nitrate and sulfate) and organic polyatomic (dodecyl sulfate, DS) species. The coated electrodes thus obtained were characterized by electrochemical techniques and SEM. They showed improved electrocatalytic activities towards hydrogen peroxide oxidation compared to that of a bare SPCE. In particular, the insertion of DS anions inside PAA films provided a special sensitivity to the electrocatalysis of H2O2, which endowed these electrodes with promising analytical features for H2O2 quantification. We obtained a wide linear response for H2O2 within a range of 5 mu M to 3 mM and a limit of detection of 1.43 +/- 0.10 mu M (signal-to-noise ratio of 3). Furthermore, sensitivity was 72.4 +/- 0.49 nA.mu M-1.cm(-2) at a relatively low electrocatalytic oxidation overpotential of 0.5 V vs. Ag. The applicability of this boosted system was tested by the analysis of H2O2 in commercial samples of a hair lightener and an antiseptic and was corroborated by spectrophotometric methods.
引用
收藏
页数:14
相关论文
共 58 条
[21]   Electrochemical detection of extracellular hydrogen peroxide in Arabidopsis thaliana: a real-time marker of oxidative stress [J].
Gonzalez-Sanchez, M. I. ;
Gonzalez-Macia, L. ;
Perez-Prior, M. T. ;
Valero, E. ;
Hancock, J. ;
Killard, A. J. .
PLANT CELL AND ENVIRONMENT, 2013, 36 (04) :869-878
[22]   Fluorescence Decrease of Conjugated Polymers by the Catalytic Activity of Horseradish Peroxidase and Its Application in Phenolic Compounds Detection [J].
Gonzalez-Sanchez, M. I. ;
Laurenti, M. ;
Rubio-Retama, J. ;
Valero, E. ;
Lopez-Cabarcos, E. .
BIOMACROMOLECULES, 2011, 12 (04) :1332-1338
[23]   Searching for the fluorescence quenching mechanism of conjugated polymers by cytochrome c [J].
Gonzalez-Sanchez, Maria-Isabel ;
Laurenti, Marco ;
Rubio-Retama, Jorge ;
Lopez-Cabarcos, Enrique ;
Valero, Edelmira .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 510 :300-308
[24]   One-step synthesis of poly(thionine)-Au nano-network and nanowires and its application for non-enzyme biosensing of hydrogen peroxide [J].
Han, Jingman ;
Ma, Jie ;
Ma, Zhanfang .
ELECTROCHEMISTRY COMMUNICATIONS, 2013, 33 :47-50
[25]   Electrochemical Post-Functionalization of Conducting Polymers [J].
Inagi, Shinsuke ;
Fuchigami, Toshio .
MACROMOLECULAR RAPID COMMUNICATIONS, 2014, 35 (09) :854-867
[26]   Measurement of Total Antioxidant Capacity by Electrogenerated Iodine at Disposable Screen Printed Electrodes [J].
Isabel Gonzalez-Sanchez, Maria ;
Agrisuelas, Jeronimo ;
Valero, Edelmira ;
Compton, Richard G. .
ELECTROANALYSIS, 2017, 29 (05) :1316-1323
[27]   Conducting polymers in electronic chemical sensors [J].
Janata, J ;
Josowicz, M .
NATURE MATERIALS, 2003, 2 (01) :19-24
[28]   Voltammetric anion recognition by a highly cross-linked polyviologen film [J].
Kamata, K ;
Suzuki, T ;
Kawai, T ;
Iyoda, T .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 473 (1-2) :145-155
[29]  
Karyakin AA, 1999, ELECTROANAL, V11, P149, DOI 10.1002/(SICI)1521-4109(199903)11:3<149::AID-ELAN149>3.0.CO
[30]  
2-G