Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers

被引:6
作者
Kumar, Prachi [1 ]
Bhargava, Rahul [1 ]
Arora, Yogesh C. [2 ]
Kaushal, Sidharth [3 ]
Kumar, Manjushri [4 ]
机构
[1] Sharda Univ, Dept Pathol, Greater Noida, Uttar Pradesh, India
[2] Sharda Univ, Sch Med Sci & Res, Dept Ophthalmol, Greater Noida, Uttar Pradesh, India
[3] Laser Eye Clin, Dept Ophthalmol, Noida, Uttar Pradesh, India
[4] Narayan Med Coll & Hosp, Dept Microbiol, Sasaram, Bihar, India
关键词
Conjunctival impression cytology (CIC); contact lens; dry eye; lens wear time; OCULAR SURFACE; DISEASE; SYMPTOMS; OMEGA-3-FATTY-ACIDS; EXPRESSION;
D O I
10.4103/0970-9371.171242
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Aims: Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. Setting: A case control study was done at three referral eye centers. Materials and Methods: The eyes of 230 contact lens users were compared to 250 eyes of age-and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS c) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R-2 > 0.5 was considered significant. Results: As compared to controls (r(2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r(2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r(2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r(2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. Conclusion: CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 48 条
[31]   Longitudinal analysis of taurine induced effects on the tear proteome of contact lens wearers and dry eye patients using a RP-RP-Capillary-HPLC-MALDI TOF/TOF MS approach [J].
Funke, Sebastian ;
Azimi, Diana ;
Wolters, Dominik ;
Grus, Franz H. ;
Pfeiffer, Norbert .
JOURNAL OF PROTEOMICS, 2012, 75 (11) :3177-3190
[32]   Translation and validation of the 8-item contact lens dry eye questionnaire (CLDEQ-8) among Chinese soft contact lens wearers [J].
Gao, Jiajia ;
Lai, Zhipeng ;
Hu, Yin ;
Yang, Xiao .
CONTACT LENS & ANTERIOR EYE, 2025, 48 (03)
[33]   Oral Omega-3 Fatty Acid Treatment for Dry Eye in Contact Lens Wearers [J].
Bhargava, Rahul ;
Kumar, Prachi .
CORNEA, 2015, 34 (04) :413-420
[34]   Conjunctival Changes in Wearers of Frequent Replacement Hydrogel and Frequent Replacement Silicone Hydrogel Contact Lenses: Comparison Using Impression Cytology Technique [J].
Aydin, Rukiye ;
Soylemezoglu, Zeynep Ozbek ;
Veral, Ali .
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (01) :47-52
[35]   Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers [J].
Tianpu Gu ;
Lu Zhao ;
Zhuzhu Liu ;
Shaozhen Zhao ;
Hong Nian ;
Ruihua Wei .
BMC Ophthalmology, 20
[36]   Efficacy and Safety of Artificial Tears Containing Lipidure and Hypromellose for the Treatment of Moderate Dry Eye Disease in Contact Lens Wearers [J].
Gagliano, Caterina ;
Zeppieri, Marco ;
Longo, Antonio ;
Rubegni, Giovanni ;
Amato, Roberta ;
Foti, Roberta ;
Cappellani, Francesco ;
Cocuzza, Massimiliano ;
Visalli, Federico ;
Cannizzaro, Ludovica ;
Avitabile, Alessandro ;
Gagliano, Giuseppe ;
Lapenna, Lucia ;
D'Esposito, Fabiana .
MEDICINA-LITHUANIA, 2024, 60 (02)
[37]   Comparison of the efficacy of eyelid warming masks and artificial tears for dry eye symptoms in contact lens wearers [J].
Jeon, Jaehee ;
Park, Sihyun .
CONTACT LENS & ANTERIOR EYE, 2021, 44 (01) :30-34
[38]   Factors influencing the 8-item contact lens dry eye questionnaire score and comparison of translations in Japanese soft contact lens wearers [J].
Koh, Shizuka ;
Chalmers, Robin ;
Yamasaki, Katsuhide ;
Kawasaki, Ryo ;
Nishida, Kohji .
CONTACT LENS & ANTERIOR EYE, 2022, 45 (05)
[39]   Evaluation of the Correlation Between Tear Meniscus Parameters and Conventional Dry Eye Tests [J].
Bayhan, Seray Aslan ;
Bayhan, Hasan Ali ;
Muhafiz, Ersin ;
Can, Izzet .
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (06) :446-450
[40]   Free radical production in patients undergoing long-term topical antiglaucoma treatment or contact lens wearers by impression cytology specimens [J].
Debbasch, C ;
Pisella, PJ ;
Rat, P ;
Warnet, JM ;
Baudouin, C .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2000, 23 (03) :239-244