Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers

被引:6
作者
Kumar, Prachi [1 ]
Bhargava, Rahul [1 ]
Arora, Yogesh C. [2 ]
Kaushal, Sidharth [3 ]
Kumar, Manjushri [4 ]
机构
[1] Sharda Univ, Dept Pathol, Greater Noida, Uttar Pradesh, India
[2] Sharda Univ, Sch Med Sci & Res, Dept Ophthalmol, Greater Noida, Uttar Pradesh, India
[3] Laser Eye Clin, Dept Ophthalmol, Noida, Uttar Pradesh, India
[4] Narayan Med Coll & Hosp, Dept Microbiol, Sasaram, Bihar, India
关键词
Conjunctival impression cytology (CIC); contact lens; dry eye; lens wear time; OCULAR SURFACE; DISEASE; SYMPTOMS; OMEGA-3-FATTY-ACIDS; EXPRESSION;
D O I
10.4103/0970-9371.171242
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Aims: Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. Setting: A case control study was done at three referral eye centers. Materials and Methods: The eyes of 230 contact lens users were compared to 250 eyes of age-and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS c) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R-2 > 0.5 was considered significant. Results: As compared to controls (r(2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r(2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r(2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r(2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. Conclusion: CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 48 条
[21]   DRY EYE IN CONTACT LENS WEARERS AS A GROWING PUBLIC HEALTH PROBLEM [J].
Pili, Kristijan ;
Kastelan, Snjezana ;
Karabatic, Mirela ;
Kasun, Boris ;
Culig, Borna .
PSYCHIATRIA DANUBINA, 2014, 26 :528-532
[22]   The ability of the Contact Lens Dry Eye Questionnaire (CLDEQ)-8 to detect ocular surface alterations in contact lens wearers [J].
Lopez-de la Rosa, Alberto ;
Arroyo-del Arroyo, Cristina ;
Enriquez-de-Salamanca, Amalia ;
Pinto-Fraga, Jose ;
Lopez-Miguel, Alberto ;
Gonzalez-Garcia, Maria J. .
CONTACT LENS & ANTERIOR EYE, 2019, 42 (03) :273-277
[23]   Objective Assessment of Squamous Metaplasia of Conjunctival Epithelial Cells as Associated With Soft Contact Lens Wear Versus Non-Lens Wearers [J].
Doughty, Michael J. .
CORNEA, 2014, 33 (10) :1095-1102
[24]   Tear Film Dynamics of Soft Contact Lens-Induced Dry Eye [J].
Kaido, Minako ;
Kawashima, Motoko ;
Ishida, Reiko ;
Tsubota, Kazuo .
CURRENT EYE RESEARCH, 2020, 45 (07) :782-788
[25]   Evaluation of conjunctival morphology in thyroid associated eye disease by use of impression cytology [J].
Ozkan, SB ;
Soylev, MF ;
Vahapoglu, H ;
Can, D ;
Arsan, AK ;
Duman, S .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 1997, 75 (02) :145-147
[26]   Contact lens-related dry eye and ocular surface changes with mapping technique in long-term soft silicone hydrogel contact lens wearers [J].
Sengor, Tomris ;
Kurna, Sevda Aydin ;
Ozbay, Nurver ;
Ertek, Semahat ;
Aki, Suat ;
Altun, Ahmet .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 :S17-S23
[27]   Evaluation of the effect of topical cyclosporine A with impression cytology in dry eye patients [J].
Yuksel, Bora ;
Bozdag, Berkant ;
Acar, Memed ;
Topaloglu, Engin .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (04) :675-679
[28]   Morphological characteristics of Meibomian Glands and their Influence on Dry Eye disease in contact lens wearers [J].
von Ahrentschildt, Anke ;
Hanenberg, Laura ;
Robich, Matthew L. ;
Jones-Jordan, Lisa A. ;
Marx, Sebastian ;
Sickenberger, Wolfgang ;
Powell, Daniel R. ;
Kwan, Justin T. ;
Wong, Stephanie ;
Srinivasan, Sruthi ;
Jones, Lyndon ;
Pucker, Andrew D. .
OCULAR SURFACE, 2022, 24 :93-99
[29]   Changes in Corneal Dendritic Cell and Sub-basal Nerve in Long-Term Contact Lens Wearers With Dry Eye [J].
Liu, Qiaoli ;
Xu, Zhiqiang ;
Xu, Yangyang ;
Zhang, Junsong ;
Li, Yong ;
Xia, Jiahui ;
Wang, Yuzhou ;
He, Xiaoxing ;
Qu, Jia ;
Hu, Liang .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (04) :238-244
[30]   Evaluation of ocular surface and tear function-A review of current approaches for dry eye [J].
Koh, Shizuka ;
Rao, Srinivas ;
Srinivas, Sanjeev ;
Tong, Louis ;
Young, Alvin .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (06) :1883-1891