False negative fecal occult blood tests due to delayed sample return in colorectal cancer screening

被引:76
作者
van Rossum, Leo G. M. [1 ]
van Rijn, Anne F. [2 ]
van Oijen, Martijn G. H. [1 ]
Fockens, Paul [2 ]
Laheij, Robert J. F. [1 ]
Verbeek, Andre L. M. [3 ,4 ]
Jansen, Jan B. M. J. [1 ]
Dekker, Evelien [2 ]
机构
[1] Radboud Univ Nijmegen, Dept Gastroenterol & Hepatol, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Gastroenterol & Hepatol, NL-1105 AZ Amsterdam, Netherlands
[3] Radboud Univ Nijmegen, Dept Epidemiol & Biostat, Med Ctr, NL-6500 HB Nijmegen, Netherlands
[4] Radboud Univ Nijmegen, HTA, Med Ctr, NL-6500 HB Nijmegen, Netherlands
关键词
colorectal cancer; mass screening; fecal occult blood test; sample stability; false negative; POPULATION; NEOPLASIA;
D O I
10.1002/ijc.24458
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Delayed return of immunochemical fecal occult blood test (iFOBT) samples to a laboratory might cause false negatives because of hemoglobin degradation. Quantitative iFOBT's became increasingly more accepted in colorectal cancer screening. Therefore, we studied the effects of delay between sampling and laboratory delivery on iFOBT performance. IFOBT positivity (>= 50 ng/ml hemoglobin) in colorectal cancer screening participants without delay between sampling and laboratory delivery (< 5 days), was compared with positivity in participants with >= 5 and >= 7 days delay. Additionally, positive tests were stored at room temperature and retested 5 times within 10-14 days. The sampling date was reported by 61% (n = 3,767) of the participants: in 19% delay was >= 5 days and in 5% >= 7 days. Compared with no-delay, the adenoma detection rate was already significantly decreased after 2,5 days delay (OR 0.6; 95% CI 0.4-0.9). We retested iFOBT samples of 170 positives of which 139 (82%) had a colonoscopy: 45 (32%) had advanced adenomas (not colorectal cancer) and 8 (6%) had colorectal cancer. Mean daily fecal hemoglobin decrease was 29 ng/ml (S.D. 38 and median 11 ng/ml). In patients with advanced adenomas, hemoglobin in the sample was < 50 ng/ml in 5 (11%) 23 days after the initial test and in 16 (36%) after 10-14 days. Seven days after the initial test, 2 (25%) colorectal cancer patients became false negative. Both had stage I colorectal cancer and initial values below 100 ng/ml, where the average for stage I is 532 ng/ml. Delay in sample return increased false negative immunochemical FOBT's. Mainly precursor lesions, but also colorectal cancer, will be missed due to delayed sample return. (C) 2009 UICC
引用
收藏
页码:746 / 750
页数:5
相关论文
共 13 条
  • [1] Basic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood
    Castiglione, G
    Grazzini, G
    Miccinesi, G
    Rubeca, T
    Sani, C
    Turco, P
    Zappa, M
    [J]. JOURNAL OF MEDICAL SCREENING, 2002, 9 (03) : 99 - 103
  • [2] Chiang Chien-Hua, 2006, Kaohsiung Journal of Medical Sciences, V22, P223
  • [3] Screening for colorectal cancer in Uruguay with an immunochemical faecal occult blood test
    Fenocchi, Eduardo
    Martinez, Luz
    Tolve, Julio
    Montano, Daniel
    Rondan, Mariella
    Parra-Blanco, Adolfo
    Eishi, Yoshinobu
    [J]. EUROPEAN JOURNAL OF CANCER PREVENTION, 2006, 15 (05) : 384 - 390
  • [4] Colorectal cancer screening programme by faecal occult blood test in Tuscany: first round results
    Grazzini, G
    Castiglione, G
    Ciabattoni, C
    Franceschini, F
    Giorgi, D
    Gozzi, S
    Mantellini, P
    Lopane, P
    Perco, M
    Rubeca, T
    Salvadori, P
    Visioli, CB
    Zappa, M
    [J]. EUROPEAN JOURNAL OF CANCER PREVENTION, 2004, 13 (01) : 19 - 26
  • [5] HORIUCHI Y, 2003, JPN J CLIN LAB AUTOM, V28, P404
  • [6] Evaluation of an immunochemical fecal occult blood test with automated reading in screening for colorectal cancer in a general average-risk population
    Launoy, GD
    Bertrand, HJ
    Berchi, C
    Talbourdet, VY
    Guizard, AVN
    Bouvier, VM
    Caces, ER
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2005, 115 (03) : 493 - 496
  • [7] A quantitative immunochemical faecal occult blood test is more efficient for detecting significant colorectal neoplasia than a sensitive guaiac test
    Levi, Z
    Hazazi, R
    Rozen, P
    Vilkin, A
    Waked, A
    Niv, Y
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2006, 23 (09) : 1359 - 1364
  • [8] A quantitative immunochemical fecal occult blood test for colorectal neoplasia
    Levi, Zohar
    Rozen, Paul
    Hazazi, Rachel
    Vilkin, Alex
    Waked, Amal
    Maoz, Eran
    Birkenfeld, Shlomo
    Leshno, Moshe
    Niv, Yaron
    [J]. ANNALS OF INTERNAL MEDICINE, 2007, 146 (04) : 244 - 255
  • [9] Rozen P, 2006, MED SCI MONITOR, V12, pMT27
  • [10] Evaluation of diagnostic accuracy of screening by fecal occult blood testing (FOBT). Comparison of FOB Gold and OC Sensor assays in a consecutive prospective screening series
    Rubeca, T.
    Rapi, S.
    Confortini, M.
    Brogioni, A.
    Grazzini, G.
    Zappa, A.
    Puliti, D.
    Castiglione, G.
    Ciatto, S.
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2006, 21 (03) : 157 - 161