Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode

被引:20
|
作者
Lin, Xiaoyun [1 ]
Ni, Yongnian [1 ,2 ]
Pei, Xueying [1 ]
Kokot, Serge [3 ]
机构
[1] Nanchang Univ, Sch Chem, Nanchang 330031, Jiangxi, Peoples R China
[2] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[3] Queensland Univ Technol, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
QUANTITATIVE MEASUREMENT; METHYLENE-BLUE; IN-SITU; SENSOR; NANOPARTICLES; REDUCTION; TOXICITY; CATALYST; ACID; FILM;
D O I
10.1039/c6ay03022j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor capable of direct detection of DNA damage induced by clenbuterol (CLB) has been developed. A glassy carbon electrode (GCE) was modified using reduced graphene oxide-Nafion and dsDNA to produce a dsDNA/RGO-Nafion/GCE sensor. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), and the results at each stage of the electrode construction were interpreted. They indicated that the electrochemical oxidation peak currents of guanine and adenine at the electrode (dsDNA/RGO-Nafion/GCE) significantly increased as compared with those at the untreated electrode (dsDNA/GCE). Based on this, the sensor was used to measure the change of the oxidation peak currents for guanine and adenine between the intact and damaged dsDNA in the sensor films, and the DNA damage was successfully detected. Furthermore, the plot of peak current decline for the guanine and adenine versus the concentration of CLB was linear in the range of 5.0 x 10(-7) to 4.0 x 10(-6) mol L-1, with a limit of detection (LOD) of 3.2 x 10(-7) mol L-1, which provided a good method to determine CLB indirectly.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [41] Electrochemical determination of imidacloprid using poly(carbazole)/chemically reduced graphene oxide modified glassy carbon electrode
    Lei, Wu
    Wu, Qiuju
    Si, Weimeng
    Gu, Zhenyan
    Zhang, Yuehua
    Deng, Jiping
    Hao, Qingli
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 183 : 102 - 109
  • [42] A sensitive biosensor for cyanide detection using modified glassy carbon electrode with reduced graphene oxide and immobilization of horseradish peroxidase
    Ghanavati, Mahdi
    Moraveji, Mostafa Keshavarz
    Iranshahi, Davood
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2024, 102 (03) : 1031 - 1038
  • [43] Electrochemical Determination of Paracetamol at Poly(3-Methylthiophene)/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Li, Caiwei
    Si, Weimeng
    Wu, Yuting
    Zhang, Cheng
    Lei, Wu
    Hao, Qingli
    NANO, 2018, 13 (09)
  • [44] Simultaneous and selective electrochemical determination of dihydroxybenzene isomers at a reduced graphene oxide and copper nanoparticles composite modified glassy carbon electrode
    Palanisamy, Selvakumar
    Karuppiah, Chelladurai
    Chen, Shen-Ming
    Yang, Cheng-Yu
    Periakaruppan, Prakash
    ANALYTICAL METHODS, 2014, 6 (12) : 4271 - 4278
  • [45] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [46] Detection of Guanine and Adenine Using an Aminated Reduced Graphene Oxide Functional Membrane-Modified Glassy Carbon Electrode
    Li, Di
    Yang, Xiao-Lu
    Xiao, Bao-Lin
    Geng, Fang-Yong
    Hong, Jun
    Sheibani, Nader
    Moosavi-Movahedi, Ali Akbar
    SENSORS, 2017, 17 (07):
  • [47] Simultaneous Electrochemical Detection of Catechol and Hydroquinone Based on a Carbon Nanotube Paste Electrode Modified with Electro-Reduced Graphene Oxide
    Chen, Tingfei
    Liu, Chao
    Liu, Xiaojun
    Zhu, Chunnan
    Zheng, Dongyun
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (18)
  • [48] Electrochemical Detection of Daphnetin Based on a Glassy Carbon Electrode Modified with Nafion and RGO-TEPA
    Zhou, Ming
    Sheng, Yunjie
    Li, Yangchun
    Wang, Yurong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 1 - 18
  • [49] Electrochemical Determination of Propranolol using Reduced Graphene Oxide Modified Carbon Paste Electrode
    Purushothama, Hanumasagara Thimmappa
    Nayaka, Yanjerappa Arthoba
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (11): : 1575 - 1589
  • [50] Determination of Tocopherol Using Reduced Graphene Oxide-Nafion Hybrid-Modified Electrode in Pharmaceutical Capsules and Vegetable Oil Samples
    Filik, Hayati
    Avan, Asiye Aslihan
    Aydar, Sevda
    Cakar, Seyda
    FOOD ANALYTICAL METHODS, 2016, 9 (06) : 1745 - 1753