Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode

被引:20
|
作者
Lin, Xiaoyun [1 ]
Ni, Yongnian [1 ,2 ]
Pei, Xueying [1 ]
Kokot, Serge [3 ]
机构
[1] Nanchang Univ, Sch Chem, Nanchang 330031, Jiangxi, Peoples R China
[2] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[3] Queensland Univ Technol, Sch Chem Phys & Mech Engn, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
QUANTITATIVE MEASUREMENT; METHYLENE-BLUE; IN-SITU; SENSOR; NANOPARTICLES; REDUCTION; TOXICITY; CATALYST; ACID; FILM;
D O I
10.1039/c6ay03022j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical biosensor capable of direct detection of DNA damage induced by clenbuterol (CLB) has been developed. A glassy carbon electrode (GCE) was modified using reduced graphene oxide-Nafion and dsDNA to produce a dsDNA/RGO-Nafion/GCE sensor. The modified electrode was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV), and the results at each stage of the electrode construction were interpreted. They indicated that the electrochemical oxidation peak currents of guanine and adenine at the electrode (dsDNA/RGO-Nafion/GCE) significantly increased as compared with those at the untreated electrode (dsDNA/GCE). Based on this, the sensor was used to measure the change of the oxidation peak currents for guanine and adenine between the intact and damaged dsDNA in the sensor films, and the DNA damage was successfully detected. Furthermore, the plot of peak current decline for the guanine and adenine versus the concentration of CLB was linear in the range of 5.0 x 10(-7) to 4.0 x 10(-6) mol L-1, with a limit of detection (LOD) of 3.2 x 10(-7) mol L-1, which provided a good method to determine CLB indirectly.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [1] Electrochemical Behavior and Determination of Matrine by the Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode
    Zhang, Hongjiao
    Xiong, Huabin
    Gao, Yuntao
    Wang, Zhengwei
    Li, Xiaofen
    Ma, Xiaoyan
    Yang, Hongqiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6348 - 6358
  • [2] Acetylcholinesterase Biosensor for the Detection of Methyl Parathion at an Electrochemically Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode
    Jeyapragasam, Tharini
    Saraswathi, R.
    Chen, Shen-Ming
    Chen, Tse-Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 4768 - 4781
  • [3] Electrochemical Sensing of Acetaminophen on Electrochemically Reduced Graphene Oxide-Nafion Composite Film Modified Electrode
    Filik, Hayati
    Cetintas, Gamze
    Avan, A. Aslihan
    Koc, Serkan Naci
    Boz, Ismail
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (04): : 5724 - 5737
  • [4] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961
  • [5] A poly-(L-serine)/reduced graphene oxide-Nafion supported on glassy carbon (PLS/rGO-Nafion/GCE) electrode for the detection of naproxen in aqueous solutions
    Hung, Chang-Mao
    Huang, Chin-Pao
    Chen, Chiu-Wen
    Dong, Cheng-Di
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (09) : 12450 - 12461
  • [6] pH robust electrochemical detection of 4-nitrophenol on a reduced graphene oxide modified glassy carbon electrode
    Wiench, Piotr
    Grzyb, Bartosz
    Gonzalez, Zoraida
    Menendez, Rosa
    Handke, Bartosz
    Gryglewicz, Grazyna
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 787 : 80 - 87
  • [7] Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Peik-See, Teo
    Pandikumar, Alagarsamy
    Nay-Ming, Huang
    Hong-Ngee, Lim
    Sulaiman, Yusran
    SENSORS, 2014, 14 (08): : 15227 - 15243
  • [8] Electrochemical Sensor Based on Nafion/Gold Nanoparticle/Electrochemically Reduced Graphene Oxide Composite-Modified Glassy Carbon Electrode for the Detection of Diuron
    Qin, Jianfang
    Qin, YingLian
    Jiang, Xiuping
    Du, Yajin
    Du, Yajing
    Yao, Chen-Zhong
    Wang, Xi
    Yang, Haiying
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (11): : 11203 - 11214
  • [9] Electrochemically Reduced Graphene Oxide-nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
    Lv, Yajie
    Wang, Fang
    Zhu, Hui
    Zou, Xiaorong
    Tao, Cheng-An
    Wang, Jianfang
    NANOMATERIALS AND NANOTECHNOLOGY, 2016, 6
  • [10] Electrochemical Detection of Paracetamol Using Graphene Oxide -Modified Glassy Carbon Electrode
    Zidan, Mohammed
    Zawawi, Ruzniza Mohd
    Erhayem, Mohamed
    Salhin, Abdussalam