Thermoelectric power plants contribute 90% of the electricity generated in the United States. Steam condensation in the power generation cycle creates a need for cooling, often accomplished using large amounts of water. These large water requirements can lead to negative consequences of power plants dialing down or shutting down during times of low water availability. Consequently, water constraints can translate into energy constraints. Projected future population growth and changing climate conditions might also increase the competition for water in many areas, motivating a resource accounting analysis to both establish a baseline of current water requirements and simulate possible impacts from future water and energy management decisions. Our analysis of the current water demands for power generation, focused on the state of Illinois, combined existing digital spatial datasets with engineering basic principles to synthesize a geographic information systems (GIS) model of current and projected water demand for thermoelectric power plants. We evaluated two potential future cases based on water use implications: (1) a shift in fuel from coal to natural gas, and (2) a shift in cooling technology from open-loop to closed-loop cooling. Our results show that a shift from coal-generated to natural gas-generated electricity could decrease statewide water consumption by 0.10 billion m(3)/yr (32% decrease) and withdrawal by 7.9 billion m(3)/yr (37% decrease), on average. A shift from open-loop to closed-loop cooling technologies could decrease withdrawals by an average of 21 billion m(3)/yr (96% decrease), with the tradeoff of increasing statewide water consumption for power generation by 0.18 billion m(3)/yr (58% increase). Furthermore, we performed an economic analysis of retrofitting open-loop cooling systems to closed-loop cooling, revealing an annual cost between $0.58 and $1.3 billion to retrofit the 22 open-loop cooling plants considered, translating to an effective water price between $0.03 and $0.06/m(3). The synergies and tradeoffs between water resources and power generation yield interesting implications for integrated decision making and policy in Illinois and elsewhere. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 48 条
  • [11] Byers EA, 2015, P I CIV ENG EN, P1
  • [12] Energy's Thirst for Water in China
    Cai, Beiming
    Zhang, Bing
    Bi, Jun
    Zhang, Wenjing
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (20) : 11760 - 11768
  • [13] Life Cycle Water Consumption for Shale Gas and Conventional Natural Gas
    Clark, Corrie E.
    Horner, Robert M.
    Harto, Christopher B.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (20) : 11829 - 11836
  • [14] COHEN RONNIE, 2004, ENERGY DOWN DRAIN HI
  • [15] Conca J., 2015, ILLINOIS NUCL POWER
  • [16] Department of Energy, 2008, EL REL IMP MAND COOL
  • [17] Diehl T H, 2013, 20135188 US GEOL SUR
  • [18] Electric Power Research Institute, 2002, WAT SUST US WAT CONS, V3
  • [19] Environmental Protection Agency, 2014, EPA821R14002
  • [20] Water: A critical resource in the thermoelectric power industry
    Feeley, Thomas J., III
    Skone, Timothy J.
    Stlegel, Gary J., Jr.
    McNemar, Andrea
    Nemeth, Michael
    Schimmoller, Brian
    Murph, James T.
    Manfredo, Lynn