Integrating water resources and power generation: The energy-water nexus in Illinois

被引:154
作者
DeNooyer, Tyler A. [1 ]
Peschel, Joshua M. [1 ]
Zhang, Zhenxing [2 ]
Stillwell, Ashlynn S. [1 ]
机构
[1] Univ Illinois, Civil & Environm Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Prairie Res Inst, Illinois State Water Survey, Champaign, IL 61820 USA
关键词
Policy; Power generation; Scenario analysis; Sustainability; Water resources; GAS; US; IMPACTS; SYSTEMS;
D O I
10.1016/j.apenergy.2015.10.071
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermoelectric power plants contribute 90% of the electricity generated in the United States. Steam condensation in the power generation cycle creates a need for cooling, often accomplished using large amounts of water. These large water requirements can lead to negative consequences of power plants dialing down or shutting down during times of low water availability. Consequently, water constraints can translate into energy constraints. Projected future population growth and changing climate conditions might also increase the competition for water in many areas, motivating a resource accounting analysis to both establish a baseline of current water requirements and simulate possible impacts from future water and energy management decisions. Our analysis of the current water demands for power generation, focused on the state of Illinois, combined existing digital spatial datasets with engineering basic principles to synthesize a geographic information systems (GIS) model of current and projected water demand for thermoelectric power plants. We evaluated two potential future cases based on water use implications: (1) a shift in fuel from coal to natural gas, and (2) a shift in cooling technology from open-loop to closed-loop cooling. Our results show that a shift from coal-generated to natural gas-generated electricity could decrease statewide water consumption by 0.10 billion m(3)/yr (32% decrease) and withdrawal by 7.9 billion m(3)/yr (37% decrease), on average. A shift from open-loop to closed-loop cooling technologies could decrease withdrawals by an average of 21 billion m(3)/yr (96% decrease), with the tradeoff of increasing statewide water consumption for power generation by 0.18 billion m(3)/yr (58% increase). Furthermore, we performed an economic analysis of retrofitting open-loop cooling systems to closed-loop cooling, revealing an annual cost between $0.58 and $1.3 billion to retrofit the 22 open-loop cooling plants considered, translating to an effective water price between $0.03 and $0.06/m(3). The synergies and tradeoffs between water resources and power generation yield interesting implications for integrated decision making and policy in Illinois and elsewhere. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 48 条
  • [1] [Anonymous], 2014, CONTRIBUTION WORKING
  • [2] [Anonymous], 2006, C INT EN WAT US DEP
  • [3] [Anonymous], 2002, TECH REP
  • [4] [Anonymous], 2002, TECH REP
  • [5] Implications of high renewable electricity penetration in the US for water use, greenhouse gas emissions, land-use, and materials supply
    Arent, Doug
    Pless, Jacquelyn
    Mai, Trieu
    Wiser, Ryan
    Hand, Maureen
    Baldwin, Sam
    Heath, Garvin
    Macknick, Jordan
    Bazilian, Morgan
    Schlosser, Adam
    Denholm, Paul
    [J]. APPLIED ENERGY, 2014, 123 : 368 - 377
  • [6] Aspinall A., 2009, WATER ELECTRICITY GE
  • [7] Averyt K, 2011, FRESHW US US POW PLA
  • [8] Baker J., 2014, J AM WATER RESOUR AS, P1
  • [9] Barta M., 2015, Towards a new History for the Egyptian Old Kingdom: Perspectives on the Pyramid Age, P1
  • [10] The Conservation Nexus: Valuing Interdependent Water and Energy Savings in Arizona
    Bartos, Matthew D.
    Chester, Mikhail V.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (04) : 2139 - 2149