Assessment of an alanine EPR dosimetry technique with enhanced precision and accuracy

被引:59
作者
Hayes, RB
Haskell, EH
Wieser, A
Romanyukha, AA
Hardy, BL
Barrus, JK
机构
[1] Ctr Appl Dosimetry, Salt Lake City, UT 84108 USA
[2] GSF Forschungszentrum Umwelt & Gesundheit, Inst Strahlenschutz, D-85758 Oberschleissheim, Germany
[3] Russian Acad Sci, Inst Met Phys, Sverdlovsk 620219, Russia
[4] Univ Utah, Radiol Hlth Dept, Salt Lake City, UT 84112 USA
关键词
EPR; ESR; ionizing radiation; dosimetry; alanine; nondestructive;
D O I
10.1016/S0168-9002(99)00957-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Dose reconstruction in the course of a series of blind tests demonstrated that an accuracy of 10 mGy for low doses and 1% for high doses can be achieved using EPR spectroscopy. This was accomplished using a combination of methodologies including polynomial filtration of the EPR spectrum, dosimeter rotation during scanning, use of an EPR standard fixed into the resonator and subtraction of all nonradiogenic signals. Doses were reconstructed over the range of 0.01-1000 Gy using this compound spectral EPR analysis. This EPR technique, being equally applicable to fractionated doses (such as those delivered during multiple radiotherapy treatments), was verified to exhibit dose reciprocity. Irradiated alanine dosimeters which were stored exhibited compound spectral EPR signal fading of ca 3 % over 9 months. All error estimates given in this paper are given at the 1 standard deviation level and unless otherwise specified do not account for uncertainties in source calibration. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:453 / 461
页数:9
相关论文
共 29 条
[1]   FADING CHARACTERISTICS OF IRRADIATED ALANINE PELLETS - THE IMPORTANCE OF PREIRRADATION CONDITIONING [J].
ARBER, JM ;
SHARPE, PHG .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :19-22
[2]   SOURCES OF UNCERTAINTY IN THERAPY LEVEL ALANINE DOSIMETRY [J].
BARTOLOTTA, A ;
FATTIBENE, P ;
ONORI, S ;
PANTALONI, M ;
PETETTI, E .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :13-17
[3]  
BARTOLOTTA A, 1989, APPL RADIAT ISOTOPES, V40, P1003, DOI 10.1016/0883-2889(89)90032-4
[4]   A study of the composite character of the ESR spectrum of alanine [J].
Callens, F ;
vanLaere, K ;
Mondelaers, W ;
Matthys, P ;
Boesman, E .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1241-1250
[5]  
CONINCKX F, 1989, APPL RADIAT ISOTOPES, V40, P977, DOI 10.1016/0883-2889(89)90027-0
[6]   EXPERIENCE WITH A NEW POLYMER-ALANINE DOSIMETER IN A HIGH-ENERGY PARTICLE ACCELERATOR ENVIRONMENT [J].
CONINCKX, F ;
SCHONBACHER, H .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :67-71
[7]   Progress in quality control of alanine dosimeters [J].
Dolo, JM ;
Lecerf, N ;
Tartes, I .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1165-1168
[9]   Electron paramagnetic resonance techniques and space biodosimetry [J].
Haskell, EH ;
Hayes, RB ;
Kenner, GH ;
Sholom, SV ;
Chumak, VI .
RADIATION RESEARCH, 1997, 148 (05) :S51-S59
[10]   A high sensitivity EPR technique for alanine dosimetry [J].
Haskell, EH ;
Hayes, RB ;
Kenner, GH .
RADIATION PROTECTION DOSIMETRY, 1998, 77 (1-2) :43-49