Radially localized measurements of superthermal electrons using oblique electron cyclotron emission

被引:18
作者
Preische, S [1 ]
Efthimion, PC [1 ]
Kaye, SM [1 ]
机构
[1] PRINCETON UNIV, PLASMA PHYS LAB, PRINCETON, NJ 08543 USA
关键词
D O I
10.1063/1.871564
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
It is shown that radial localization of optically thin electron cyclotron emission from superthermal electrons can be imposed by observation of emission upshifted from the thermal cyclotron resonance in the horizontal midplane of a tokamak. A new and unique diagnostic has been proposed and operated to make radially localized measurements of superthermal electrons during lower hybrid current drive on the Princeton Beta Experiment-Modified (PBX-M) tokamak [Bernabei, et al., Phys. Fluids B 5, 2562 (1993)]. The superthermal electron density profile as well as moments of the electron energy distribution as a function of radius are measured during lower hybrid current drive. The time evolution of these measurements after the lower hybrid power is turned off are given and the observed behavior reflects the collisional isotropization of the energy distribution and radial diffusion of the spatial profile. (C) 1996 American Institute of Physics.
引用
收藏
页码:4065 / 4073
页数:9
相关论文
共 50 条
  • [21] RESULTS OF ELECTRON-CYCLOTRON EMISSION MEASUREMENTS IN TFR
    BROSSIER, P
    RAMPONI, G
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (02): : 181 - 181
  • [22] A Michelson Interferometer for Electron Cyclotron Emission Measurements on EAST
    刘永
    Stefan SCHMUCK
    赵海林
    John FESSEY
    Paul TRIMBLE
    刘祥
    朱则英
    臧庆
    胡立群
    Plasma Science and Technology, 2016, (12) : 1148 - 1154
  • [23] The effects of kinetic instabilities on the electron cyclotron emission from runaway electrons
    Liu, Chang
    Shi, Lei
    Hirvijoki, Eero
    Brennan, Dylan P.
    Bhattacharjee, Amitava
    Paz-Soldan, Carlos
    Austin, Max E.
    NUCLEAR FUSION, 2018, 58 (09)
  • [24] RADIAL RESOLUTION EVALUATION FOR OBLIQUE-VIEW ELECTRON CYCLOTRON EMISSION FOR ITER
    Subhash, P. V.
    Ghai, Y.
    Amit, S. K.
    Begum, A. M.
    Vasu, P.
    FUSION SCIENCE AND TECHNOLOGY, 2015, 67 (04) : 705 - 717
  • [25] USING PERPENDICULAR ELECTRON-CYCLOTRON EMISSION TO DIAGNOSE THE THERMAL-BARRIER ELECTRONS IN A TANDEM MIRROR
    CELATA, CM
    NUCLEAR FUSION, 1985, 25 (01) : 35 - 48
  • [26] RESOLUTION OF ELECTRON CYCLOTRON EMISSION MEASUREMENTS OF MAGNETOHYDRODYNAMIC MODES IN ITER
    Austin, M. E.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (04) : 647 - 650
  • [27] Electron cyclotron emission measurements in JT-60U
    Isei, N
    Isayama, A
    Ishida, S
    Sato, M
    Oikawa, T
    Fukuda, T
    Nagashima, A
    Iwama, N
    FUSION ENGINEERING AND DESIGN, 2001, 53 : 213 - 220
  • [28] 10 channel grating polychromator for the measurements of electron cyclotron emission
    Kawahata, Kazuo
    Sakai, Kiyomi
    Ando, Ritoku
    Ohara, Sinji
    Fujita, Junji
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1988, 27 (12): : 2349 - 2355
  • [29] Secondary electron emission of the relief surface: A study at an oblique incidence of primary electrons
    Novikov, Yu.A.
    Rakov, A.V.
    Stekolin, I.Yu.
    Surface Investigation X-Ray, Synchrotron and Neutron Techniques, 1998, 13 (09): : 1119 - 1126
  • [30] KINETIC MEASUREMENTS USING ELECTRON CYCLOTRON RESONANCE
    MOTHES, KG
    SCHULTES, E
    SCHINDLE.RN
    BERICHTE DER BUNSEN-GESELLSCHAFT FUR PHYSIKALISCHE CHEMIE, 1971, 75 (10): : 1137 - &