Antibody immobilization on to polystyrene substrate-on-chip immunoassay for horse IgG based on fluorescence

被引:43
|
作者
Darain, Farzana [1 ]
Gan, Kai Ling [1 ]
Tjin, Swee Chuan [2 ]
机构
[1] Nanyang Technol Univ, Biomed Engn Res Ctr, Singapore 639553, Singapore
[2] Nanyang Technol Univ, Photon Res Ctr, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
Polystyrene; Covalent bonding; Microfluidic card; Fluorescence; Horse IgG; SELF-ASSEMBLED MONOLAYERS; MICROFLUIDIC DEVICE; SURFACE MODIFICATION; POLYMER; IMMUNOSENSOR; ASSAY; POLY(DIMETHYLSILOXANE); SPECTROSCOPY; FILMS;
D O I
10.1007/s10544-008-9275-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A simple microfluidic immunoassay card was developed based on polystyrene (PS) substrate for the detection of horse IgG, an inexpensive model analyte using fluorescence microscope. The primary antibody was captured onto the PS based on covalent bonding via a self-assembled monolayer (SAM) of thiol to pattern the surface chemistry on a gold-coated PS. The immunosensor chip layers were fabricated from sheets by CO2 laser ablation. The functionalized PS surfaces after each step were characterized by contact angle measurement, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). After the antibody-antigen interaction as a sandwich immunoassay with a fluorescein isothiocyanate (FITC)-conjugated secondary antibody, the intensity of fluorescence was measured on-chip to determine the concentration of the target analyte. The present immunosensor chip showed a linear response range for horse IgG between 1 mu g/ml and 80 mu g/ml (r = 0.971, n = 3). The detection limit was found to be 0.71 mu g/ml. The developed microfluidic system can be extended for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.
引用
收藏
页码:653 / 661
页数:9
相关论文
共 50 条
  • [41] Upconversion Nanoparticles and Monodispersed Magnetic Polystyrene Microsphere Based Fluorescence Immunoassay for the Detection of Sulfaquinoxaline in Animal-Derived Foods
    Hu, Gaoshuang
    Sheng, Wei
    Zhang, Yan
    Wang, Junping
    Wu, Xuening
    Wang, Shuo
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (19) : 3908 - 3915
  • [42] On-chip micro-flow polystyrene bead-based immunoassay for quantitative detection of tacrolimus (FK506)
    Murakami, Y
    Endo, T
    Yamamura, S
    Nagatani, N
    Takamura, Y
    Tamiya, E
    ANALYTICAL BIOCHEMISTRY, 2004, 334 (01) : 111 - 116
  • [43] QUANTIFICATION OF STEROIDS VIA A POLYMER LINKED 2ND ANTIBODY ENZYME-IMMUNOASSAY SYSTEM - METHODS OF LINKING ANTI-RABBIT IGG TO POLYSTYRENE
    KESLER, DJ
    KHAZALI, H
    FAVERO, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 115 - PMSE
  • [44] A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection
    Cheng, Yongjian
    Xie, Bo
    Liang, Yifan
    Liu, Xinmei
    Chen, Haojie
    Li, Jiadong
    Lei, Hongtao
    Xiao, Zhili
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1395 - 1402
  • [45] Sensitive immunoassay for porcine pseudorabies antibody based on fluorescence signal amplification induced by cation exchange in CdSe nanocrystals
    XuePu Li
    Kun Chen
    Liang Huang
    DongLian Lu
    JianGong Liang
    HeYou Han
    Microchimica Acta, 2013, 180 : 303 - 310
  • [46] A label-free, direct and noncompetitive FRET immunoassay for ochratoxin A based on intrinsic fluorescence of an antigen and antibody complex
    Li, Taihua
    Jeon, Ki-Seok
    Suh, Yung Doug
    Kim, Min-Gon
    CHEMICAL COMMUNICATIONS, 2011, 47 (32) : 9098 - 9100
  • [47] Sensitive immunoassay for porcine pseudorabies antibody based on fluorescence signal amplification induced by cation exchange in CdSe nanocrystals
    Li, XuePu
    Chen, Kun
    Huang, Liang
    Lu, DongLian
    Liang, JianGong
    Han, HeYou
    MICROCHIMICA ACTA, 2013, 180 (3-4) : 303 - 310
  • [48] ANALYSIS OF GRANULOCYTE-REACTIVE ANTIBODIES USING AN IMMUNOASSAY BASED UPON MONOCLONAL-ANTIBODY-SPECIFIC IMMOBILIZATION OF GRANULOCYTE ANTIGENS
    BUX, J
    KOBER, B
    KIEFEL, V
    MUELLERECKHARDT, C
    TRANSFUSION MEDICINE, 1993, 3 (02) : 157 - 162
  • [49] Simple and more sensitive immune complex transfer enzyme immunoassay for antibody IgG to reverse transcriptase of HIV-1 using microplates, modified polystyrene solid phase, and fluororeader
    Hashida, S
    Ishikawa, S
    Nakamoto, H
    Tanaka, S
    Kojima, M
    Ishikawa, E
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1996, 10 (05) : 294 - 301
  • [50] Facile engineered polymeric microdevice via co-coupling of phenylboronic acid and Protein A for oriented antibody immobilization enables substantial signal enhancement for an enhanced fluorescence immunoassay
    Chang, Jianguo
    Gao, Nailong
    Dai, Peng
    Zhu, Ziming
    You, Hui
    Han, Wei
    Li, Lu
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 346