Risk Factors and Long-Term Survival of Octogenarians and Nonagenarians Undergoing Transvenous Lead Extraction Procedures

被引:9
作者
Jachec, Wojciech [1 ]
Polewczyk, Anna [2 ,3 ]
Segreti, Luca [4 ]
Bongiorni, Maria Grazia [4 ]
Kutarski, Andrzej [5 ]
机构
[1] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, Katowice, Poland
[2] Jan Kochanowski Univ Humanities & Sci, Coll Med, Kielce, Poland
[3] Swietokrzyskie Cardiol Ctr, Dept Cardiac Surg, 45,Grunwaldzka St, PL-25736 Kielce, Poland
[4] Univ Hosp Pisa, Dept Cardiol, Pisa, Italy
[5] Med Univ, Dept Cardiol, Lublin, Poland
关键词
Transvenous lead extraction; Octogenarians; Nonagenarians; Complication rate; Long-term outcome; CARDIOVERTER-DEFIBRILLATOR LEADS; EXPERT CONSENSUS STATEMENT; CARDIAC-SURGERY; COMPLICATIONS; MORTALITY; OUTCOMES; SAFETY; FRAILTY;
D O I
10.1159/000511358
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Introduction: Transvenous lead extraction (TLE) has become a frequently used tool for the management of complications related to pacemakers, implantable cardiac defibrillators and cardiac resynchronization therapy devices. However, it is still a matter of debate whether the lead extraction procedure is a safe treatment choice in the elderly. Methods: We collected the clinical information from 3,810 patients undergoing TLE in 2 high-volume centers (Poland and Italy) between 2006 and 2017. We tested risk factors, effectiveness, safety and long-term survival in 3 groups of patients: those aged 80-89.99 years, >= 90 years and 30-79.99 years. Results: Lower BMI, lower levels of hemoglobin and more comorbidities characterized the patients, whose ages ranged from 80 to 89.99 years. Those aged >= 90 years most often had single-chamber pacemakers. Octogenarians and nonagenarians were more often undergoing TLE due to infectious indications (57.19 and 74.29 vs. 45.35% in younger individuals). Lead age and the number of leads extracted were comparable in the 3 groups. In octogenarians, leads were more often removed using standard extraction techniques: simple traction and mechanical dilatators, whereas in nonagenarians TLE was more complex. The duration of the procedure was shorter in older patients, while clinical and procedural effectiveness was similar to that in younger individuals. The rate of major complications related to TLE did not differ between octogenarians and younger subjects (2.0 vs. 1.38%, p = ns), and the number of procedure-related risk factors was smaller in older people. Nonagenarians did not develop any major complication related to TLE. Long-term mortality after TLE was similar among octogenarians and nonagenarians (39.67 and 40.00%) but higher than in younger patients (24.41; p < 0.001 and 0.05). Conclusions: Lead extraction procedures appear effective and safe in octogenarians and nonagenarians, comparable to younger individuals. Procedure-related risk in the elderly is not associated with most of the typical risk factors encountered in younger subjects, but only with the higher number of pacemaker, implantable cardiac defibrillator and cardiac resynchronization therapy device procedures before TLE. Long-term survival after TLE was found to be similar among octogenarians and nonagenarians being about 60% at over 3 years of follow-up. Age alone should not be considered a risk factor for the occurrence of major complications or procedure-related death, and therefore it should not prevent candidacy for TLE.
引用
收藏
页码:36 / 48
页数:13
相关论文
共 22 条
[1]   Addition of Frailty and Disability to Cardiac Surgery Risk Scores Identifies Elderly Patients at High Risk of Mortality or Major Morbidity [J].
Afilalo, Jonathan ;
Mottillo, Salvatore ;
Eisenberg, Mark J. ;
Alexander, Karen P. ;
Noiseux, Nicolas ;
Perrault, Louis P. ;
Morin, Jean-Francois ;
Langlois, Yves ;
Ohayon, Samuel M. ;
Monette, Johanne ;
Boivin, Jean-Francois ;
Shahian, David M. ;
Bergman, Howard .
CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2012, 5 (02) :222-U140
[2]   Predictors of Complications of Endovascular Chronic Lead Extractions from Pacemakers and Defibrillators: A Single-Operator Experience [J].
Agarwal, Sunil K. ;
Kamireddy, Swapna ;
Nemec, Jan ;
Voigt, Andrew ;
Saba, Samir .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (02) :171-175
[3]   2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS [J].
Bongiorni, Maria G. ;
Burri, Haran ;
Deharo, Jean C. ;
Starck, Christoph ;
Kennergren, Charles ;
Saghy, Laszlo ;
Rao, Archana ;
Tascini, Carlo ;
Lever, Nigel ;
Kutarski, Andrzej ;
Lozano, Ignacio Fernandez ;
Strathmore, Neil ;
Costa, Roberto ;
Epstein, Laurence ;
Love, Charles ;
Blomstrom-Lundqvist, Carina ;
Fauchier, Laurent ;
Defaye, Pascal ;
Arnar, David O. ;
Klug, Didier ;
Boveda, Serge ;
Nielsen, Jens Cosedis ;
Boriani, Giuseppe ;
Zhang, Shu ;
Martin, Andrew Paul ;
Prutkin, Jordan M. ;
de Zuloaga, Claudio .
EUROPACE, 2018, 20 (07) :1217-+
[4]   Outcomes of patients requiring emergent surgical or endovascular intervention for catastrophic complications during transvenous Lead extraction [J].
Brunner, Michael P. ;
Cronin, Edmond M. ;
Wazni, Oussama ;
Baranowski, Bryan ;
Saliba, Walid I. ;
Sabik, Joseph F. ;
Lindsay, Bruce D. ;
Wilkoff, Bruce L. ;
Tarakji, Khaldoun G. .
HEART RHYTHM, 2014, 11 (03) :419-425
[5]   Transvenous extraction of implantable cardioverter-defibrillator leads under advisory-A comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads [J].
Brunner, Michael P. ;
Cronin, Edmond M. ;
Jacob, Jessen ;
Duarte, Valeria E. ;
Tarakji, Khaldoun G. ;
Martin, David O. ;
Callahan, Thomas ;
Borek, P. Peter ;
Cantillon, Daniel J. ;
Niebauer, Mark J. ;
Saliba, Walid I. ;
Kanj, Mohamed ;
Wazni, Oussama ;
Baranowski, Bryan ;
Wilkoff, Bruce L. .
HEART RHYTHM, 2013, 10 (10) :1444-1450
[6]   Procedural outcomes and long-term survival following lead extraction in octogenarians [J].
El-Chami, Mikhael F. ;
Sayegh, Michael N. ;
Patel, Adarsh ;
El-Khalil, Jad ;
Desai, Yaanik ;
Leon, Angel R. ;
Merchant, Faisal M. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (07) :868-872
[7]   Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach? [J].
Fu, Hai-Xia ;
Huang, Xin-Miao ;
Zhong, Li ;
Osborn, Michael J. ;
Asirvatham, Samuel J. ;
Espinosa, Raul E. ;
Brady, Peter A. ;
Lee, Hon-Chi ;
Greason, Kevin L. ;
Baddour, Larry M. ;
Sohail, Rizwan M. ;
Acker, Nancy G. ;
Hodge, David O. ;
Friedman, Paul A. ;
Cha, Yong-Mei .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (12) :1439-1447
[8]   Risk Factors Predicting Complications of Transvenous Lead Extraction [J].
Jachec, Wojciech ;
Polewczyk, Anna ;
Polewczyk, Maciej ;
Tomasik, Andrzej ;
Janion, Marianna ;
Kutarski, Andrzej .
BIOMED RESEARCH INTERNATIONAL, 2018, 2018
[9]   Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age [J].
Kempa, Maciej ;
Budrejko, Szymon ;
Piepiorka, Marta ;
Rogowski, Jan ;
Raczak, Grzegorz ;
Kozlowski, Dariusz .
KARDIOLOGIA POLSKA, 2013, 71 (02) :130-135
[10]   2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction [J].
Kusumoto, Fred M. ;
Schoenfeld, Mark H. ;
Wilkoff, Bruce L. ;
Berul, Charles I. ;
Birgersdotter-Green, Ulrika M. ;
Carrillo, Roger ;
Cha, Yong-Mei ;
Clancy, Jude ;
Deharo, Jean-Claude ;
Ellenbogen, Kenneth A. ;
Exner, Derek ;
Hussein, Ayman A. ;
Kennergren, Charles ;
Krahn, Andrew ;
Lee, Richard ;
Love, Charles J. ;
Madden, Ruth A. ;
Mazzetti, Hector Alfredo ;
Moore, JoEllyn Carol ;
Parsonnet, Jeffrey ;
Patton, Kristen K. ;
Rozner, Marc A. ;
Selzman, Kimberly A. ;
Shoda, Morio ;
Srivathsan, Komandoor ;
Strathmore, Neil F. ;
Swerdlow, Charles D. ;
Tompkins, Christine ;
Wazni, Oussama .
HEART RHYTHM, 2017, 14 (12) :E503-+