Intrapartum fetal heart rate between 150 and 160 bpm at or after 40 weeks and labor outcome

被引:8
作者
Ghi, Tullio [1 ]
Di Pasquo, Elvira [1 ]
Dall'Asta, Andrea [1 ]
Commare, Arianna [1 ]
Melandri, Elena [1 ]
Casciaro, Alessia [1 ]
Fieni, Stefania [1 ]
Frusca, Tiziana [1 ]
机构
[1] Univ Parma, Dept Obstet & Gynecol, Via Gramsci 14, I-43126 Parma, Italy
关键词
cardiotocography; chorioamnionitis; chronic hypoxia; fetal heart rate; neonatal acidosis; CEREBRAL-PALSY; COMPUTERIZED ANALYSIS; EPIDURAL ANALGESIA; RATE PATTERNS; CHORIOAMNIONITIS; ASSOCIATION; PARAMETERS; INFECTION; PREGNANCY; TERM;
D O I
10.1111/aogs.14024
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction A baseline fetal heart rate between 110 and 160 bpm is considered normal. However, among normal fetuses the average baseline heart rate has been shown to diminish progressively and the 90th centile of the fetal heart rate at 40 weeks of gestation has been consistently found at around 150 bpm. The aim of our study was to assess the labor and neonatal outcome of fetuses at 40 gestational weeks or beyond, whose intrapartum baseline fetal heart rate was between 150 and 160 bpm. Material and methods Retrospective cohort study including singleton pregnancies with spontaneous onset of labor, gestational age between 40(+0) and 42(+0) weeks, category I CTG trace according to the FIGO guidelines 2015 with baseline fetal heart rate between 110 and 160 bpm during the first 60 minutes of active labor. Exclusion criteria were maternal hyperpyrexia at admission, fetal arrhythmias, maternal tachycardia (>110 bpm) and uterine tachysystole (>5 contractions/10 minutes). The following outcomes were compared between fetuses with a baseline ranging between 110 and 149 bpm and those with a baseline ranging between 150 and 160 bpm: incidence of meconium-stained amniotic fluid, intrapartum hyperpyrexia, mode of delivery, Apgar at 5 minutes <7, arterial pH <7.1 and Neonatal Intensive Care Unit admission, incidence of a composite adverse neonatal outcome. Results In all, 1004 CTG traces were included in the analysis, 860 in Group 110-149 bpm and 144 in Group 150-160 bpm. Group 150-160 bpm had a significantly higher incidence of meconium-stained amniotic fluid (odds ratio [OR] 2.6; 95% CI 1.8-3.8), maternal intrapartum hyperpyrexia (OR 4.7; 95% CI 1.1-14.6), urgent/emergent cesarean section for suspected fetal distress (OR 13.4; 95% CI 3.3-54.3), Apgar <7 at 5th min (OR 9.13; 95% CI 1.5-55.1) and neonatal acidemia (OR 3.5; 95% CI 1.5-55.1). Logistic regression including adjustiing for potential confounders showed that fetal heart rate between 150 and 160 bpm is an independent predictor of meconium-stained amniotic fluid (adjusted odds ratio [aOR] 2.2; 95% CI 1.5-3.3), cesarean section during labor for fetal distress (aOR 10.7; 95% CI 2.9-44.6), neonatal acidemia (aOR 2.6; 95% CI 1.1-6.7) and adverse composite neonatal outcome (aOR 2.6; 95% CI 1.2-5.6). Conclusions In fetuses at 40 weeks or beyond, an intrapartum fetal heart rate baseline ranging between 150 and 160 bpm seems associated with a higher incidence of labor complications.
引用
收藏
页码:548 / 554
页数:7
相关论文
共 17 条
  • [1] Intrapartum fetal heart rate patterns and perinatal outcome in chorioamnionitis at or beyond 34 weeks of gestation
    Muraoka, Junsuke
    Kodama, Yuki
    Ohashi, Masanao
    Goto, Tomoko
    Sameshima, Hiroshi
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2021, 47 (03) : 1110 - 1117
  • [2] Intrapartum fetal heart rate patterns in infants (≥34 weeks) with poor neurological outcome
    Kodama, Yuki
    Sarrieshima, Hiroshi
    Ikeda, Tomoaki
    Ikenoue, Tsuyomu
    EARLY HUMAN DEVELOPMENT, 2009, 85 (04) : 235 - 238
  • [3] Intrapartum fetal heart rate patterns preceding terminal bradycardia in infants (&gt;34weeks) with poor neurological outcome: A regional population-based study in Japan
    Kodama, Yuki
    Sameshima, Hiroshi
    Yamashita, Rie
    Oohashi, Masanao
    Ikenoue, Tsuyomu
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2015, 41 (11) : 1738 - 1743
  • [4] Implementation of a revised classification for intrapartum fetal heart rate monitoring and association to birth outcome: A national cohort study
    Jonsson, Maria
    Soderling, Jonas
    Ladfors, Lars
    Nordstrom, Lennart
    Nilsson, Marianne
    Algovik, Michael
    Norman, Mikael
    Holzmann, Malin
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2022, 101 (02) : 183 - 192
  • [5] Association between intrapartum fetal heart rate patterns and neonatal abstinence syndrome in methadone exposed neonates
    Leeman, Lawrence M.
    Brown, Steffen A.
    Albright, Brittany
    Skipper, Betty
    Hsi, Andrew
    Rayburn, William F.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2011, 24 (07) : 955 - 959
  • [6] Interpreting fetal heart rate tracings - Is there a difference between labor and delivery nurses and obstetricians?
    Beckmann, CA
    VanMullem, C
    Beckmann, CRB
    Broekhuizen, FE
    JOURNAL OF REPRODUCTIVE MEDICINE, 1997, 42 (10) : 647 - 650
  • [7] Differences between external and internal fetal heart rate monitoring during the second stage of labor: a prospective observational study
    Nunes, Ines
    Ayres-de-Campos, Diogo
    Costa-Santos, Cristina
    Bernardes, Joao
    JOURNAL OF PERINATAL MEDICINE, 2014, 42 (04) : 493 - 498
  • [8] How to read fetal heart rate tracings in labor: a comparison between ACOG and NICE guidelines
    Buscicchio, Giorgia
    Gentilucci, Lucia
    Martorana, Rossana
    Martino, Cristina
    Tranquilli, Andrea Luigi
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 (12) : 2797 - 2798
  • [9] Do fetal heart rate deceleration patterns during labor differ between various umbilical cord abnormalities?
    Hasegawa, Junichi
    Matsuoka, Ryu
    Ichizuka, Kiyotake
    Nakamura, Masamitsu
    Sekizawa, Akihiko
    Okai, Takashi
    JOURNAL OF PERINATAL MEDICINE, 2009, 37 (03) : 276 - 280
  • [10] Early rehabilitation after stroke: relationship between the heart rate variability and functional outcome
    Scherbakov, Nadja
    Barkhudaryan, Anush
    Ebner, Nicole
    von Haehling, Stephan
    Anker, Stefan D.
    Joebges, Michael
    Doehner, Wolfram
    ESC HEART FAILURE, 2020, 7 (05): : 2983 - 2991