Detection of vesicular stomatitis virus using a capacitive immunosensor

被引:4
|
作者
Hanna, Darrin M. [1 ]
Gross, Brooks A. [1 ]
Kandlikar, Sachin [1 ]
Lempicki, Elizabeth [1 ]
Oakley, Barbara A. [1 ]
Stryker, Gabrielle A. [1 ]
机构
[1] Oakland Univ, Sch Engn & Comp Sci, Rochester, MI 48063 USA
来源
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2005年
关键词
antigen; antibody; immunosensor; capacitance; VSV; bacteria; virus;
D O I
10.1109/IEMBS.2005.1616466
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes the detection of Vesicular Stomatitis Virus using a novel capacitive immunosensor technology, whereby the respective antibodies for the antigens were used as a means for chemical detection on separate sensors. Devices were fabricated using standard etching and metal plating techniques, followed by immobilization of antibodies. Detection of antigen was performed by measuring voltage change due to changes in capacitance as antigen bound to the antibody surface. Capacitance changes were detected upon binding of specific antigen to the surface. This rugged, prototype device detected VSV down to the 2 pg/ml range.
引用
收藏
页码:534 / 537
页数:4
相关论文
共 50 条