Measurement of longitudinal sulfur isotopic variations by laser ablation MC-ICP-MS in single human hair strands

被引:28
作者
Santamaria-Fernandez, Rebeca [1 ]
Giner Martinez-Sierra, Justo [2 ]
Marchante-Gayon, J. M. [2 ]
Ignacio Garcia-Alonso, J. [2 ]
Hearn, Ruth [1 ]
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
[2] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
Mass spectrometry/ICP-MS; Laser ablation; Forensics; Sulfur; Isotope ratio; MC-ICP-MS; PLASMA-MASS SPECTROMETRY; RATIO MEASUREMENTS; MULTIELEMENTAL CHARACTERIZATION; DELTA-S-34; MEASUREMENTS; HUMAN IDENTIFICATION; S-34; ANALYSIS; SCALP HAIR; NAILS; C-13; N-15;
D O I
10.1007/s00216-009-2615-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for the measurement of longitudinal variations of sulfur isotope amount ratios in single hair strands using a laser ablation system coupled to a multi-collector inductively coupled plasma mass spectrometer (LA-MC-ICP-MS) is reported here for the first time. Ablation parameters have been optimized for the measurement of sulfur isotope ratios in scalp human hair strands of 80-120-mu m thickness and different washing procedures have been evaluated. The repeatability of the method has been tested and the ability to measure sulfur isotopic variations in 1,000-mu m-long hair segments has been evaluated. A horse hair sample previously characterized for carbon and nitrogen isotope ratios in an interlaboratory study has been characterized by LA-MC-ICP-MS to be used as an in-house standard for the bracketing of human hair strands. S-34/S-32 isotope amount ratios have been measured and corrected for instrumental mass bias adopting the external standardization approach using National Institute of Standards and Technology (NIST) RM8553 and full uncertainty budgets have been calculated using the Kragten approach. Results are reported as both 34S/32S isotope amount ratios and delta SV-CDT values (sulfur isotopic differences relative to a reference sample expressed in the Vienna Canyon Diablo Troilite (V-CDT) scale) calculated using NIST RM8553, NIST RM8554, and NIST RM8556 to anchor results to the V-CDT scale. The main advantage of the new method versus conventional gas source isotope ratio mass spectrometry measurements is that longitudinal variations in sulfur isotope amount ratios can be resolved. Proof of concept is shown with human scalp hair strands from three individuals, two UK residents and one traveler (long periods of time abroad). The method enables monitoring of longitudinal isotope ratio variations in single hair strands. Absolute ratios are reported and delta S-34(V-CDT) values are plotted for comparison. Slight variations of <1.2% were detected in the hair strands from UK residents whereas the traveler presented a variation of >5 parts per thousand. Thus, the measurement of sulfur isotopic variations in hair samples has potential to be an indicator of geographical origin and recent movements and could be used in combination with isotope ratio measurements in water/foodstuffs from different geographical locations to provide important information in nutritional and geographical studies.
引用
收藏
页码:225 / 233
页数:9
相关论文
共 42 条
[1]   Spatial location of the space charge effect in individual ion clouds using monodisperse dried microparticulate injection with a twin quadrupole inductively coupled plasma mass spectrometer [J].
Allen, LA ;
Leach, JJ ;
Houk, RS .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2384-2391
[2]  
[Anonymous], 2002, CHEM PHYS BEHAV HUMA
[3]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[4]  
BermejoBarrera P, 1996, CLIN CHEM, V42, P1287
[5]   Stable isotope (13C, 15N and 34S) analysis of the hair of modern humans and their domestic animals [J].
Bol, R ;
Pflieger, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (23) :2195-2200
[6]   Multiple stable isotope (18O, 13C, 15N and 34S) analysis of Human hair to identify the recent migrants in a rural community in SW England [J].
Bol, Roland ;
Marsh, Jen ;
Heaton, Tim H. E. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) :2951-2954
[7]   d34S measurements of sulfur by multicollector inductively coupled plasma mass spectrometry [J].
Clough, Robert ;
Evans, Peter ;
Catterick, Tim ;
Evans, E. Hywel .
ANALYTICAL CHEMISTRY, 2006, 78 (17) :6126-6132
[8]  
Coleman M., 2004, HDB STABLE ISOTOPE A, VI
[9]   Calibrated sulfur isotope abundance ratios of three IAEA sulfur isotope reference materials and V-CDT with a reassessment of the atomic weight of sulfur [J].
Ding, T ;
Valkiers, S ;
Kipphardt, H ;
De Bièvre, P ;
Taylor, PDP ;
Gonfiantini, R ;
Krouse, R .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2001, 65 (15) :2433-2437
[10]   Hydrogen and oxygen isotope ratios in human hair are related to geography [J].
Ehleringer, James R. ;
Bowen, Gabriel J. ;
Chesson, Lesley A. ;
West, Adam G. ;
Podlesak, David W. ;
Cerling, Thure E. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (08) :2788-2793