Detection of inspiratory flow limitation during sleep by computer assisted respiratory inductive plethysmography

被引:46
作者
Kaplan, V [1 ]
Zhang, JN [1 ]
Russi, EW [1 ]
Bloch, KE [1 ]
机构
[1] Univ Zurich Hosp, Dept Internal Med, Div Pulm, CH-8091 Zurich, Switzerland
关键词
flow limitation; noninvasive monitoring; respiratory inductive plethysmography; sleep apnoea; sleep disturbance; upper airway;
D O I
10.1034/j.1399-3003.2000.15.24.x
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The potential of respiratory inductive plethysmography (RIP) to detect inspiratory flow limitation during sleep was investigated, Sixteen sleep apnoea patients underwent polysomnography, Airflow by a flowmeter attached to a nasal mask, oesophageal and mask pressure were recorded along with calibrated RIP. Presence of inspiratory flow limitation was defined by constant or decreasing flow without pressure dependence throughout significant portions of inspiration, its absence by a linear or mildly alinear pressure:airflow relationship. Based on this standard, three of various computerized RIP derived parameters, with highest performance to detect flow limitation, were identified. They were combined to an inspiratory flow limitation, (IFL)-Index(RIP), which was validated prospectively in another 10 sleep apnoea patients. RIP derived fractional inspiratory time, peak to mean inspiratory flow ratio, and ribcage contribution to tidal volume had the highest accuracy to detect flow limitation (area under the receiver operating characteristic (ROC) curves 0.81, 0.76, 0.76, respectively, 160 comparisons). Prospective validation revealed an area under the ROC curve for the IFL-Index(RIP) to detect flow limitation of 0.89 (95% confidence interval 0.85 to 0.93, 200 comparisons) with sensitivity and specificity at the point of equality of 80%. It is concluded that inspiratory flow limitation may be assessed by computer assisted analysis of respiratory inductive plethysmography derived breathing patterns with clinically acceptable accuracy.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 26 条
[1]   DEFORMATION OF CHEST WALL DURING BREATHING EFFORTS [J].
AGOSTONI, E ;
MOGNONI, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (06) :1827-&
[2]  
[Anonymous], 1992, SLEEP, V15, P174
[3]  
[Anonymous], BRIT MED J
[4]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[5]   Effect of surgical lung volume reduction on breathing patterns in severe pulmonary emphysema [J].
Bloch, KE ;
Li, YM ;
Zhang, JN ;
Bingisser, R ;
Kaplan, V ;
Weder, W ;
Russi, EW .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (02) :553-560
[6]  
Bloch KE, 1997, EUR RESPIR J, V10, P576
[7]   A PULSED DIAGONAL-BEAM ULTRASONIC AIR-FLOW METER [J].
BUESS, C ;
PIETSCH, P ;
GUGGENBUHL, W ;
KOLLER, EA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (03) :1195-1199
[8]  
Chesson AL, 1997, SLEEP, V20, P406
[9]   Assessment of inspiratory flow limitation invasively and noninvasively during sleep [J].
Clark, SA ;
Wilson, CR ;
Satoh, M ;
Pegelow, D ;
Dempsey, JA .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (03) :713-722
[10]   FLOW LIMITATION AS A NONINVASIVE ASSESSMENT OF RESIDUAL UPPER-AIRWAY RESISTANCE DURING CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY OF OBSTRUCTIVE SLEEP-APNEA [J].
CONDOS, R ;
NORMAN, RG ;
KRISHNASAMY, I ;
PEDUZZI, N ;
GOLDRING, RM ;
RAPOPORT, DM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :475-480