Refractive surprise after toric intraocular lens implantation: Graph analysis

被引:26
作者
Alpins, Noel [1 ]
Ong, James K. Y. [1 ]
Stamatelatos, George [1 ]
机构
[1] NewVis Clin, Melbourne, Vic, Australia
关键词
CATARACT-SURGERY; ROTATIONAL STABILITY; CORNEAL ASTIGMATISM; EYES; INCISIONS; BIOMETRY; VECTORS; POWER;
D O I
10.1016/j.jcrs.2013.06.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the refractive cylinder effect of rotating a toric intraocular lens (IOL) and identify the sources of refractive astigmatic surprise after toric IOL implantation. SETTING: Private practice, Melbourne, Australia. DESIGN: Experimental study. METHODS: Vergence formulas using a standard reduced eye model were used to bring all lens powers to the corneal plane. Double-angle vector diagrams were then used to (1) determine the refractive cylinder effect of rotating a toric IOL and (2) show how the prevailing astigmatism and the various planning and surgical steps involved in implanting a toric IOL contribute to the postoperative manifest refractive cylinder. RESULTS: An example calculation is given to illustrate the method. CONCLUSIONS: Refractive cylinder surprises can occur after toric IOL implantation. Understanding the causes enables surgeons to address contributory factors and choose an appropriate surgical method for managing individual cases of refractive cylinder surprise. (C) 2014 ASCRS and ESCRS
引用
收藏
页码:283 / 294
页数:12
相关论文
共 23 条
[11]   Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1356-1370
[12]  
International Organization for Standardization, 2003, 119792 ISO
[13]  
JAFFE N, 1975, T AM ACAD OPHTHALMOL, V79, pP615
[14]   Intraocular lens exchange due to incorrect lens power [J].
Jin, George J. C. ;
Crandall, Alan S. ;
Jones, Jason J. .
OPHTHALMOLOGY, 2007, 114 (03) :417-424
[15]   Effect of axis orientation on visual performance in astigmatic eyes [J].
Kobashi, Hidenaga ;
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Kawamorita, Takushi ;
Uozato, Hiroshi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (08) :1352-1359
[16]   Contribution of posterior corneal astigmatism to total corneal astigmatism [J].
Koch, Douglas D. ;
Ali, Shazia F. ;
Weikert, Mitchell P. ;
Shirayama, Mariko ;
Jenkins, Richard ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) :2080-2087
[17]  
Marcos S, 2011, IOL POWER, P223
[18]   Postoperative intraocular lens rotation -: A randomized comparison of plate and loop haptic implants [J].
Patel, CK ;
Ormonde, S ;
Rosen, PH ;
Bron, AJ .
OPHTHALMOLOGY, 1999, 106 (11) :2190-2195
[19]   Predicting postoperative intraocular lens position and refraction [J].
Preussner, PR ;
Wahl, J ;
Weitzel, D ;
Berthold, S ;
Kriechbaum, K ;
Findl, O .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10) :2077-2083
[20]   Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bag [J].
Shah, Gauri D. ;
Praveen, Mamidipudi R. ;
Vasavada, Abhay R. ;
Vasavada, Viraj A. ;
Rampal, Gauri ;
Shastry, Lajja R. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01) :54-59