Value of anatomical aortic valve area using real-time three-dimensional transoesophageal echocardiography in patients with aortic stenosis: a comparison between tricuspid and bicuspid aortic valves

被引:10
作者
Machida, Takafumi [1 ]
Izumo, Masaki [2 ]
Suzuki, Kengo [2 ]
Yoneyama, Kihei [2 ]
Kamijima, Ryo [2 ]
Mizukoshi, Kei [2 ]
Takai, Manabu [2 ]
Kobayashi, Yasuyuki [3 ]
Harada, Tomoo [2 ]
Miyake, Fumihiko [2 ]
Ohtaki, Eiji [2 ]
Nobuoka, Sachihiko [4 ]
Matsumoto, Naoki [1 ]
Akashi, Yoshihiro J. [2 ]
机构
[1] St Marianna Univ, Sch Med, Dept Pharmacol, Kawasaki, Kanagawa, Japan
[2] St Marianna Univ, Div Cardiol, Dept Internal Med, Sch Med,Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
[3] St Marianna Univ, Sch Med, Dept Radiol, Kawasaki, Kanagawa, Japan
[4] St Marianna Univ, Sch Med, Dept Lab Med, Kawasaki, Kanagawa, Japan
关键词
Aortic valve stenosis; Echocardiography; Three-dimensional echocardiography; ORIFICE AREA; RECOMMENDATIONS; QUANTIFICATION; IMPLANTATION; PLANIMETRY;
D O I
10.1093/ehjci/jev056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Accurate assessment of disease severity is critical for appropriate treatment of patients with aortic stenosis (AS). This study investigated the influence of aortic-valve morphology on the determination of anatomical aortic-valve area (AVA) in patients with AS. Methods and results This prospective study included 126 patients with AS who underwent transoesophageal echocardiography (TEE). Aortic valve area was measured using (i) planimetric two-dimensional (2D) TEE, (ii) volumetric three-dimensional (3D) TEE, and (iii) the continuity equation (CE) obtained with transthoracic echocardiography. Of these, 20 patients also underwent contrast-enhanced multidetector computed tomography (MDCT). Aortic-valve area was measured from multiplanar reconstruction of the MDCT images. Of the 126 patients, 20 (15.9%) were diagnosed with bicuspid AS and 106 were diagnosed with tricuspid AS. There was an excellent correlation between AVA(ADCT) and AVA(3DTEE) (r = 0.83, P < 0.001) and a somewhat lower correlation between AVAADCT and AVA(2DTEE) (r = 0.63, P = 0.006). In the tricuspid AS group, both AVA2DTEE and AVA3DTEE significantly correlated with AVA(CE) (r = 0.63, mean difference 0.13 +/- 0.24 cm(2), and r = 0.83, mean difference 0.03 +/- 0.12 cm(2), respectively, both P < 0.001). In contrast, in the bicuspid AS group, AVA3DTEE significantly correlated with AVACE (r = 0.83, mean difference 0.10 +/- 0.18 cm(2), P < 0.001), whereas AVA2DTEE did not (r = 0.42, mean difference 0.48 +/- 0.32 cm(2), P = 0.066). Conclusion Aortic-valve morphology influenced the assessment of anatomical AVA in patients with AS, and 3DTEE is useful for assessing anatomical AVA regardless of aortic-valve morphology.
引用
收藏
页码:1120 / 1128
页数:9
相关论文
共 50 条
  • [41] Comparison of Left Ventricular Outflow Geometry and Aortic Valve Area in Patients With Aortic Stenosis by 2-Dimensional Versus 3-Dimensional Echocardiography
    Saitoh, Takeji
    Shiota, Maiko
    Izumo, Masaki
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (11) : 1626 - 1631
  • [42] Validity of visual assessment of aortic valve morphology in patients with aortic stenosis using two-dimensional echocardiography
    Olena Nemchyna
    Sajjad Soltani
    Natalia Solowjowa
    Felix Schoenrath
    Yuriy Hrytsyna
    Axel Unbehaun
    Jörg Kempfert
    Julia Stein
    Christoph Knosalla
    Andreas Hagendorff
    Fabian Knebel
    Volkmar Falk
    Jan Knierim
    The International Journal of Cardiovascular Imaging, 2021, 37 : 813 - 823
  • [43] Three-dimensional demonstration of bicuspid aortic valve by 16-row multidetector computed tomography: comparison with transesophageal echocardiography
    Niinuma, H
    Yoshioka, K
    Ogino, Y
    Kawazoe, K
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (02) : 346 - 346
  • [44] Aortic Valve Stenosis Planimetry by Means of Three-Dimensional Transesophageal Echocardiography in the Real Clinical Setting: Feasibility, Reliability and Systematic Deviations
    Saura, Daniel
    de la Morena, Gonzalo
    Flores-Blanco, Pedro J.
    Oliva, Maria J.
    Caballero, Luis
    Gonzalez-Carrillo, Josefa
    Espinosa, Maria D.
    Lopez-Ruiz, Maria
    Garcia-Navarro, Miguel
    Valdes, Mariano
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (03): : 508 - 515
  • [45] The effect of aortic area measurement site on the energy loss coefficient: a comparison between echocardiography and cardiac computed tomography angiography in patients with aortic stenosis
    Yaari, Dotan
    Rubinshtein, Ronen
    Sachner, Robert
    Gaspar, Tamar
    Adawi, Salim
    Jaffe, Ronen
    Asmer, Ihab
    Ganaeem, Majdi
    Shiran, Avinoam
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2016, 33 (11): : 1649 - 1655
  • [46] Effect of Mitral Valve Repair on Mitral-Aortic Coupling: A Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Veronesi, Federico
    Caiani, Enrico G.
    Sugeng, Lissa
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Pepi, Mauro
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (05) : 524 - 531
  • [47] Role of real-time 3-dimensional transesophageal echocardiography in transcatheter aortic valve implantation
    Bouzas-Mosquera, Alberto
    Alvarez-Garcia, Nemesio
    Ortiz-Vazquez, Eduardo
    Cuenca-Castillo, Jose J.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (05) : 909 - 909
  • [48] Fused aortic valve without an elliptical-shaped systolic orifice in patients with severe aortic stenosis: cardiac computed tomography is useful for differentiation between bicuspid aortic valve with raphe and tricuspid aortic valve with commissural fusion
    Bak, So Hyeon
    Ko, Sung Min
    Song, Meong Gun
    Shin, Je Kyoun
    Chee, Hyun Kun
    Kim, Jun Suk
    EUROPEAN RADIOLOGY, 2015, 25 (04) : 1208 - 1217
  • [49] Quantitative Assessment of Mitral Valve Geometry in Patients with Degenerative Aortic Stenosis Using Real-Time 3D Transesophageal Echocardiography
    Otani, Kyoko
    Takeuchi, Masaaki
    Kaku, Kyoko
    Haruki, Nobuhiko
    Yoshitani, Hidetoshi
    Lang, Roberto M.
    Otsuji, Yutaka
    CIRCULATION, 2010, 122 (21)
  • [50] Estimation of Stroke Volume and Aortic Valve Area in Patients With Aortic Stenosis: A Comparison of Doppler-Echocardiography and Cardiac Magnetic Resonance
    Capoulade, Romain
    Le Ven, Florent
    Garcia, Julio
    Tastet, Lionel
    Dahou, Abdellaziz
    Dumesnil, Jean G.
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Pibarot, Philippe
    CIRCULATION, 2014, 130