Value of anatomical aortic valve area using real-time three-dimensional transoesophageal echocardiography in patients with aortic stenosis: a comparison between tricuspid and bicuspid aortic valves

被引:10
作者
Machida, Takafumi [1 ]
Izumo, Masaki [2 ]
Suzuki, Kengo [2 ]
Yoneyama, Kihei [2 ]
Kamijima, Ryo [2 ]
Mizukoshi, Kei [2 ]
Takai, Manabu [2 ]
Kobayashi, Yasuyuki [3 ]
Harada, Tomoo [2 ]
Miyake, Fumihiko [2 ]
Ohtaki, Eiji [2 ]
Nobuoka, Sachihiko [4 ]
Matsumoto, Naoki [1 ]
Akashi, Yoshihiro J. [2 ]
机构
[1] St Marianna Univ, Sch Med, Dept Pharmacol, Kawasaki, Kanagawa, Japan
[2] St Marianna Univ, Div Cardiol, Dept Internal Med, Sch Med,Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
[3] St Marianna Univ, Sch Med, Dept Radiol, Kawasaki, Kanagawa, Japan
[4] St Marianna Univ, Sch Med, Dept Lab Med, Kawasaki, Kanagawa, Japan
关键词
Aortic valve stenosis; Echocardiography; Three-dimensional echocardiography; ORIFICE AREA; RECOMMENDATIONS; QUANTIFICATION; IMPLANTATION; PLANIMETRY;
D O I
10.1093/ehjci/jev056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Accurate assessment of disease severity is critical for appropriate treatment of patients with aortic stenosis (AS). This study investigated the influence of aortic-valve morphology on the determination of anatomical aortic-valve area (AVA) in patients with AS. Methods and results This prospective study included 126 patients with AS who underwent transoesophageal echocardiography (TEE). Aortic valve area was measured using (i) planimetric two-dimensional (2D) TEE, (ii) volumetric three-dimensional (3D) TEE, and (iii) the continuity equation (CE) obtained with transthoracic echocardiography. Of these, 20 patients also underwent contrast-enhanced multidetector computed tomography (MDCT). Aortic-valve area was measured from multiplanar reconstruction of the MDCT images. Of the 126 patients, 20 (15.9%) were diagnosed with bicuspid AS and 106 were diagnosed with tricuspid AS. There was an excellent correlation between AVA(ADCT) and AVA(3DTEE) (r = 0.83, P < 0.001) and a somewhat lower correlation between AVAADCT and AVA(2DTEE) (r = 0.63, P = 0.006). In the tricuspid AS group, both AVA2DTEE and AVA3DTEE significantly correlated with AVA(CE) (r = 0.63, mean difference 0.13 +/- 0.24 cm(2), and r = 0.83, mean difference 0.03 +/- 0.12 cm(2), respectively, both P < 0.001). In contrast, in the bicuspid AS group, AVA3DTEE significantly correlated with AVACE (r = 0.83, mean difference 0.10 +/- 0.18 cm(2), P < 0.001), whereas AVA2DTEE did not (r = 0.42, mean difference 0.48 +/- 0.32 cm(2), P = 0.066). Conclusion Aortic-valve morphology influenced the assessment of anatomical AVA in patients with AS, and 3DTEE is useful for assessing anatomical AVA regardless of aortic-valve morphology.
引用
收藏
页码:1120 / 1128
页数:9
相关论文
共 50 条
  • [31] Incremental Utility of Real Time Three-Dimensional Tranthoracic Echocardiography in the Assessment of Congenitally Malformed Aortic Valve
    Anwar, Ashraf M.
    Nosir, Youssef F. M.
    Galal, Ahmed N.
    Al-Barakati, Mai
    Chamsi-Pasha, Hassan
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (08): : 978 - 983
  • [32] Accuracy and usefulness of aortic annular measurement using real-time three-dimensional transesophageal echocardiography: Comparison with direct surgical sizing
    Nishi, Tomoko
    Shibayama, Kentaro
    Tabata, Minoru
    Kato, Nahoko
    Noguchi, Masahiko
    Okumura, Hiroshi
    Kawano, Yuji
    Nakatsuka, Daisuke
    Obunai, Kotaro
    Kobayashi, Yoshio
    Watanabe, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2018, 71 (3-4) : 230 - 236
  • [33] Abnormal mitral-aortic intervalvular coupling in mitral valve diseases: a study using real-time three-dimensional transesophageal echocardiography
    Looi, Jen-Li
    Lee, Alex Pui-Wai
    Fang, Fang
    Hsiung, Ming C.
    Sun, Jing-Ping
    Yin, Wei-Hsian
    Wei, Jeng
    Tsai, Shen-Kou
    Wan, Song
    Wong, Randolph H. L.
    Underwood, Malcolm J.
    Lin, Qing-Shan
    Jin, Chun-Na
    Chen, Liu
    Yu, Cheuk-Man
    CLINICAL RESEARCH IN CARDIOLOGY, 2015, 104 (10) : 831 - 842
  • [34] Real-time three-dimensional transesophageal echocardiographic evaluation of the association of bicuspid aortic valve andmitral posterior leaflet hypoplasia
    Saura, Daniel
    Jose Oliva, M.
    Sanchez-Galian, Maria J.
    Gonzalez, Josefa
    Caballero, Luis
    Mateo-Martinez, Alicia
    de la Morena, Gonzalo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 195 : 334 - 335
  • [35] Intraoperative Monitoring With Transesophageal Real-Time Three-Dimensional Echocardiography During Transapical Prosthetic Aortic Valve Implantation
    Marcos-Alberca, Pedro
    Luis Zamorano, Jose
    Sanchez, Tibisay
    Maroto, Luis
    Perez de Isla, Leopoldo
    Almeria, Carlos
    Macaya, Carlos
    Rodriguez, Enrique
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (03): : 352 - 356
  • [36] Abnormal mitral–aortic intervalvular coupling in mitral valve diseases: a study using real-time three-dimensional transesophageal echocardiography
    Jen-Li Looi
    Alex Pui-Wai Lee
    Fang Fang
    Ming C. Hsiung
    Jing-Ping Sun
    Wei-Hsian Yin
    Jeng Wei
    Shen-Kou Tsai
    Song Wan
    Randolph HL Wong
    Malcolm J. Underwood
    Qing-Shan Lin
    Chun-Na Jin
    Liu Chen
    Cheuk-Man Yu
    Clinical Research in Cardiology, 2015, 104 : 831 - 842
  • [37] Effect of aortic regurgitant jet direction on mitral valve leaflet remodeling: a real-time three-dimensional transesophageal echocardiography study
    Hirasawa, Kensuke
    Izumo, Masaki
    Sasaoka, Taro
    Ashikaga, Takashi
    Suzuki, Kengo
    Harada, Tomoo
    Isobe, Mitsuaki
    Akashi, Yoshihiro J.
    SCIENTIFIC REPORTS, 2017, 7
  • [38] Intraoperative, Real-Time Three-Dimensional Transesophageal Echocardiography for the Transcatheter Placement of an Edwards SAPIEN Aortic Valve in the Mitral Position for Severe Mitral Stenosis
    Maxwell, Cory D.
    Daley, Sean M.
    Swaminathan, Madhav
    Nicoara, Alina
    ANESTHESIA AND ANALGESIA, 2015, 121 (06) : 1456 - 1459
  • [39] Calculation of left ventricular outflow tract area using three-dimensional echocardiography -: Influence on quantification of aortic stenosis
    Menzel, T
    Mohr-Kahaly, S
    Wagner, S
    Fischer, T
    Brückner, A
    Meyer, J
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (06): : 373 - 379
  • [40] Impact of Energy Loss Index and Valvuloarterial Impedance in Patients with Aortic Stenosis Using Three-Dimensional Echocardiography
    Saitoh, Takeji
    Tanaka, Jun
    Furugen, Azusa
    Harada, Kenji
    Izumo, Masaki
    Fukuoka, Yoko
    Shiota, Takahiro
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (04): : 654 - 659