Value of anatomical aortic valve area using real-time three-dimensional transoesophageal echocardiography in patients with aortic stenosis: a comparison between tricuspid and bicuspid aortic valves

被引:10
作者
Machida, Takafumi [1 ]
Izumo, Masaki [2 ]
Suzuki, Kengo [2 ]
Yoneyama, Kihei [2 ]
Kamijima, Ryo [2 ]
Mizukoshi, Kei [2 ]
Takai, Manabu [2 ]
Kobayashi, Yasuyuki [3 ]
Harada, Tomoo [2 ]
Miyake, Fumihiko [2 ]
Ohtaki, Eiji [2 ]
Nobuoka, Sachihiko [4 ]
Matsumoto, Naoki [1 ]
Akashi, Yoshihiro J. [2 ]
机构
[1] St Marianna Univ, Sch Med, Dept Pharmacol, Kawasaki, Kanagawa, Japan
[2] St Marianna Univ, Div Cardiol, Dept Internal Med, Sch Med,Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
[3] St Marianna Univ, Sch Med, Dept Radiol, Kawasaki, Kanagawa, Japan
[4] St Marianna Univ, Sch Med, Dept Lab Med, Kawasaki, Kanagawa, Japan
关键词
Aortic valve stenosis; Echocardiography; Three-dimensional echocardiography; ORIFICE AREA; RECOMMENDATIONS; QUANTIFICATION; IMPLANTATION; PLANIMETRY;
D O I
10.1093/ehjci/jev056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Accurate assessment of disease severity is critical for appropriate treatment of patients with aortic stenosis (AS). This study investigated the influence of aortic-valve morphology on the determination of anatomical aortic-valve area (AVA) in patients with AS. Methods and results This prospective study included 126 patients with AS who underwent transoesophageal echocardiography (TEE). Aortic valve area was measured using (i) planimetric two-dimensional (2D) TEE, (ii) volumetric three-dimensional (3D) TEE, and (iii) the continuity equation (CE) obtained with transthoracic echocardiography. Of these, 20 patients also underwent contrast-enhanced multidetector computed tomography (MDCT). Aortic-valve area was measured from multiplanar reconstruction of the MDCT images. Of the 126 patients, 20 (15.9%) were diagnosed with bicuspid AS and 106 were diagnosed with tricuspid AS. There was an excellent correlation between AVA(ADCT) and AVA(3DTEE) (r = 0.83, P < 0.001) and a somewhat lower correlation between AVAADCT and AVA(2DTEE) (r = 0.63, P = 0.006). In the tricuspid AS group, both AVA2DTEE and AVA3DTEE significantly correlated with AVA(CE) (r = 0.63, mean difference 0.13 +/- 0.24 cm(2), and r = 0.83, mean difference 0.03 +/- 0.12 cm(2), respectively, both P < 0.001). In contrast, in the bicuspid AS group, AVA3DTEE significantly correlated with AVACE (r = 0.83, mean difference 0.10 +/- 0.18 cm(2), P < 0.001), whereas AVA2DTEE did not (r = 0.42, mean difference 0.48 +/- 0.32 cm(2), P = 0.066). Conclusion Aortic-valve morphology influenced the assessment of anatomical AVA in patients with AS, and 3DTEE is useful for assessing anatomical AVA regardless of aortic-valve morphology.
引用
收藏
页码:1120 / 1128
页数:9
相关论文
共 50 条
  • [21] Measurement of the Aortic Annulus Area and Diameter by Three-Dimensional Transesophageal Echocardiography in Transcatheter Aortic Valve Replacement
    Ebuchi, Keigo
    Yoshitani, Kenji
    Kanemaru, Eiki
    Fujii, Tasuku
    Tsukinaga, Akito
    Shimahara, Yusuke
    Ohnishi, Yoshiniko
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (09) : 2387 - 2393
  • [22] Comparison of procedural, clinical and valve performance results of transcatheter aortic valve replacement in patients with bicuspid versus tricuspid aortic stenosis
    Liao, Yan-biao
    Li, Yi-jian
    Xiong, Tian-yuan
    Ou, Yuan-weixiang
    Lv, Wen-yu
    He, Jia-ling
    Li, Yi-Ming
    Zhao, Zhen-gang
    Wei, Xin
    Xu, Yuan-ning
    Feng, Yuan
    Chen, Mao
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 254 : 69 - 74
  • [23] Multidirectional myocardial function in bicuspid aortic valve stenosis patients: a three-dimensional speckle tracking analysis
    Deng, Wenhui
    Tan, Yuting
    Shi, Jiawei
    He, Shukun
    Liu, Tianshu
    Wu, Wenqian
    Li, Yuman
    Yang, Yali
    Zhang, Li
    Xie, Mingxing
    Wang, Jing
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [24] Coexisting Bicuspid Aortic and Pulmonary Valves with Normally Related Great Vessels Diagnosed by Live/Real Time Three-Dimensional Transesophageal Echocardiography
    Oz, Tugba Kemaloglu
    Karadeniz, Fatma Ozpamuk
    Gundlapalli, Hareesh
    Erer, Betul
    Sharma, Rohit K.
    Ahmed, Mustafa
    Nanda, Navin C.
    Yildirim, Aydin
    Orhan, Gokcen
    Oz, Ayhan
    Eren, Mehmet
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (02): : 218 - 221
  • [25] Real-time three-dimensional echocardiography for regional evaluation of aortic stiffness
    Nemes, Attila
    Geleijnse, Marcel L.
    Soliman, Osama I. I.
    Anwar, Ashraf M.
    Vletter, Wim B.
    ten Cate, Folkert J.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (02): : 161 - 162
  • [26] Effect of Transcatheter Aortic Valve Replacement on the Mitral Valve Apparatus and Mitral Regurgitation Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Shibayama, Kentaro
    Harada, Kenji
    Berdejo, Javier
    Mihara, Hirotsugu
    Tanaka, Jun
    Gurudevan, Swaminatha V.
    Siegel, Robert
    Jilaihawi, Hasan
    Makkar, Raj R.
    Shiota, Takahiro
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (02) : 344 - 351
  • [27] Live/Real Time Three-Dimensional Transthoracic Echocardiographic Assessment of Bicuspid Aortic Valve Morphology
    Singh, Preeti
    Dutta, Rajarshi
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (04): : 478 - 480
  • [28] Usefulness of three-dimensional transthoracic echocardiography for the classification of congenital bicuspid aortic valve in children
    Blaye-Felice, Marie-Adrienne Sadron
    Seguela, Pierre-Emmanuel
    Arnaudis, Brice
    Dulac, Yves
    Lepage, Benoit
    Acar, Philippe
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (12) : 1047 - 1052
  • [29] Estimation of Stroke Volume and Aortic Valve Area in Patients with Aortic Stenosis: A Comparison of Echocardiography versus Cardiovascular Magnetic Resonance
    Guzzetti, Ezequiel
    Capoulade, Romain
    Tastet, Lionel
    Garcia, Julio
    Le Ven, Florent
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Clavel, Marie-Annick
    Pibarot, Philippe
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (08) : 953 - +
  • [30] Measurement of the aortic annulus size by real-time three-dimensional transesophageal echocardiography
    Janosi, Rolf Alexander
    Kahlert, Philipp
    Plicht, Bjoern
    Wendt, Daniel
    Eggebrecht, Holger
    Erbel, Raimund
    Buck, Thomas
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2011, 20 (02) : 85 - 94