Analysing concurrent transcranial magnetic stimulation and electroencephalographic data: A review and introduction to the open-source TESA software

被引:234
作者
Rogasch, Nigel C. [1 ,2 ]
Sullivan, Caley [3 ]
Thomson, Richard H. [3 ]
Rose, Nathan S. [4 ]
Bailey, Neil W. [3 ]
Fitzgerald, Paul B. [3 ]
Farzan, Faranak [5 ]
Hernandez-Pavon, Julio C. [6 ]
机构
[1] Monash Univ, Brain & Mental Hlth Lab, Sch Psychol Sci, Clayton, Vic 3800, Australia
[2] Monash Univ, Monash Biomed Imaging, Monash Inst Cognit & Clin Neurosci, Clayton, Vic 3800, Australia
[3] Monash Univ, Cent Clin Sch, Monash Alfred Psychiat Res Ctr, Clayton, Vic 3800, Australia
[4] Univ Notre Dame, Dept Psychol, Notre Dame, IN 46556 USA
[5] Univ Toronto, Ctr Addict & Mental Hlth, Temerty Ctr Therapeut Brain Intervent, Toronto, ON M5S 1A1, Canada
[6] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, Espoo, Finland
基金
加拿大自然科学与工程研究理事会; 澳大利亚国家健康与医学研究理事会; 英国医学研究理事会;
关键词
Transcranial magnetic stimulation; Electroencephalography; EEGLAB; Artifacts; TMS-INDUCED ARTIFACTS; INDEPENDENT COMPONENT ANALYSIS; BRAIN RESPONSES; MOTOR CORTEX; EEG; DYNAMICS; IDENTIFICATION; MECHANISMS; SEPARATION; REDUCTION;
D O I
10.1016/j.neuroimage.2016.10.031
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The concurrent use of transcranial magnetic stimulation with electroencephalography (TMS-EEG) is growing in popularity as a method for assessing various cortical properties such as excitability, oscillations and connectivity. However, this combination of methods is technically challenging, resulting in artifacts both during recording and following typical EEG analysis methods, which can distort the underlying neural signal. In this article, we review the causes of artifacts in EEG recordings resulting from TMS, as well as artifacts introduced during analysis (e.g. as the result of filtering over high-frequency, large amplitude artifacts). We then discuss methods for removing artifacts, and ways of designing pipelines to minimise analysis-related artifacts. Finally, we introduce the TMS-EEG signal analyser (TESA), an open-source extension for EEGLAB, which includes functions that are specific for TMS-EEG analysis, such as removing and interpolating the TMS pulse artifact, removing and minimising TMS-evoked muscle activity, and analysing TMS-evoked potentials. The aims of TESA are to provide users with easy access to current TMS-EEG analysis methods and to encourage direct comparisons of these methods and pipelines. It is hoped that providing open-source functions will aid in both improving and standardising analysis across the field of TMS-EEG research.
引用
收藏
页码:934 / 951
页数:18
相关论文
共 50 条
[1]  
Hyvärinen A, 2001, INDEPENDENT COMPONENT ANALYSIS: PRINCIPLES AND PRACTICE, P71
[2]   Independent component analysis:: algorithms and applications [J].
Hyvärinen, A ;
Oja, E .
NEURAL NETWORKS, 2000, 13 (4-5) :411-430
[3]  
Ilmoniemi RJ, 2015, IEEE ENG MED BIO, P230, DOI 10.1109/EMBC.2015.7318342
[4]   Methodology for Combined TMS and EEG [J].
Ilmoniemi, Risto J. ;
Kicic, Dubravko .
BRAIN TOPOGRAPHY, 2010, 22 (04) :233-248
[5]   Neuronal responses to magnetic stimulation reveal cortical reactivity and connectivity [J].
Ilmoniemi, RJ ;
Virtanen, J ;
Ruohonen, J ;
Karhu, J ;
Aronen, HJ ;
Naatanen, R ;
Katila, T .
NEUROREPORT, 1997, 8 (16) :3537-3540
[6]   Transcranial magnetic stimulation-induced changes in EEG and responses recorded from the scalp of healthy humans [J].
Izumi, SI ;
Takase, M ;
Arita, M ;
Masakado, Y ;
Kimura, A ;
Chino, N .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (02) :319-322
[7]   Efficient reduction of stimulus artefact in TMS-EEG by epithelial short-circuiting by mini-punctures [J].
Julkunen, P. ;
Paakkoenen, A. ;
Hukkanen, T. ;
Koenoenen, M. ;
Tiihonen, P. ;
Vanhatalo, S. ;
Karhu, J. .
CLINICAL NEUROPHYSIOLOGY, 2008, 119 (02) :475-481
[8]   Imaging brain dynamics using independent component analysis [J].
Jung, TP ;
Makeig, S ;
McKeown, MJ ;
Bell, AJ ;
Lee, TW ;
Sejnowski, TJ .
PROCEEDINGS OF THE IEEE, 2001, 89 (07) :1107-1122
[9]   Alcohol reduces prefrontal cortical excitability in humans:: A combined TMS and EEG study [J].
Kähkönen, S ;
Wilenius, J ;
Nikulin, VV ;
Ollikainen, M ;
Ilmoniemi, RJ .
NEUROPSYCHOPHARMACOLOGY, 2003, 28 (04) :747-754
[10]   Removal of large muscle artifacts from transcranial magnetic stimulation-evoked EEG by independent component analysis [J].
Korhonen, Reeta J. ;
Hernandez-Pavon, Julio C. ;
Metsomaa, Johanna ;
Maki, Hanna ;
Ilmoniemi, Risto J. ;
Sarvas, Jukka .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (04) :397-407