A Comparison of Time Delay Estimation Methods and Interpolation Methods in Signal-Averaged ECG: Preliminary Results

被引:0
|
作者
Awad, Samer [1 ]
Al-Abed, Mohammad [1 ]
Al Saraira, Amer [1 ]
机构
[1] Hashemite Univ, Dept Biomed Engn, Zarqa, Jordan
关键词
signal-averaged electrocardiography; SAECG; electrocardiography; time delay estimation;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Signal-Averaged Electrocardiogram (SAECG) is a technique used to analyze ECG records for the detection of subtle changes in the electrical activity of the heart. The alignment (or time delay estimation) of PQRST complexes is the core process in creating an SAECG. In this work, we employed several time delay estimation and interpolation methods to produce SAECG using 60 normal ECG records with added synthesized -30 dB white noise. Performance evaluation was carried out by calculating the ratio of signal to noise ratio (SNR) before and after signal averaging. Spline interpolation method consistently resulted in better performance compared to the linear and cosine methods. Additionally, the results of this study indicate that the sum of square differences (SSD) and the sum of absolute differences (SAD) methods have comparable performances to that of the computationally expensive cross-correlation method.
引用
收藏
页码:371 / 374
页数:4
相关论文
共 50 条
  • [1] ADVANCED TIME-FREQUENCY METHODS FOR SIGNAL-AVERAGED ECG ANALYSIS
    JONES, DL
    TOUVANNAS, JS
    LANDER, P
    ALBERT, DE
    JOURNAL OF ELECTROCARDIOLOGY, 1993, 25 : 188 - 194
  • [2] THE SIGNAL-AVERAGED ECG - TIME - DOMAIN ANALYSIS
    BREITHARDT, G
    WICHTER, T
    FETSCH, T
    SEIFERT, T
    BORGGREFE, M
    SHENASA, M
    REINHARDT, L
    EUROPEAN HEART JOURNAL, 1993, 14 : 27 - 32
  • [3] Comparison of the QRS duration and RMS40 in signal-averaged recordings of the multichannel MCG to the signal-averaged ECG
    Achenbach, S
    Moshage, W
    Flüg, M
    Diem, B
    Schibgilla, V
    Bachmann, K
    BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 433 - 436
  • [4] COMPARISON OF TECHNIQUES FOR ANALYSIS OF THE P-WAVE SIGNAL-AVERAGED ECG
    STEINBERG, JS
    KORENSTEIN, D
    CIRCULATION, 1993, 88 (04) : 311 - 311
  • [5] Possible mechanisms for false-positive signal-averaged ECG results.
    BrembillaPerrot, B
    Beurrier, D
    Jacquemin, L
    DelaChaise, AT
    Danchin, N
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 1997, 46 (02): : 69 - 75
  • [6] Factors influencing the signal-averaged ECG in healthy subjects in time and frequency domain
    Maeso-Madronero, JL
    Israel, CW
    Bergbauer, M
    HERZ KREISLAUF, 2000, 32 (04): : 134 - 140
  • [7] Evaluation of P wave signal-averaged electrocardiographic filtering and analysis methods
    Ehlert, FA
    Korenstein, D
    Steinberg, JS
    AMERICAN HEART JOURNAL, 1997, 134 (06) : 985 - 993
  • [8] PROGNOSTIC-SIGNIFICANCE OF THE SIGNAL-AVERAGED ECG DEPENDS ON THE TIME OF RECORDING IN THE POSTINFARCTION PERIOD
    ELSHERIF, N
    URSELL, SN
    BEKHEIT, S
    FONTAINE, J
    TURITTO, G
    HENKIN, R
    CAREF, EB
    AMERICAN HEART JOURNAL, 1989, 118 (02) : 256 - 264
  • [9] DETECTION OF LATE POTENTIALS IN THE SIGNAL-AVERAGED ECG COMBINING TIME AND FREQUENCY-DOMAIN ANALYSIS
    GRAMATIKOV, BI
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (04) : 333 - 339
  • [10] Lack of impact of myocardial ischemia on the signal-averaged ECG assessment by time-domain analysis
    Schneider, MAE
    Nienaber, CA
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2002, 7 (03) : 191 - 197