Validation of the Usefulness of Dose Calculation Algorithms in Radiotherapy Planning System

被引:0
作者
Kieltyka, B. [1 ]
Rawojc, K. [1 ]
Kisielewicz, K. [2 ,3 ]
Markiewicz, I. [4 ,5 ]
机构
[1] Jagiellonian Univ, Marian Smoluchowski Inst Phys, Krakow, Poland
[2] Maria Sklodowska Curie Mem Canc Ctr, Krakow, Poland
[3] Inst Oncol, Krakow Branch, Krakow, Poland
[4] Maria Sklodowska Curie Mem Canc Ctr, Warsaw, Poland
[5] Inst Oncol, Warsaw, Poland
关键词
ANALYTICAL ANISOTROPIC ALGORITHM;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
One of the main goals of radiotherapy is to achieve tumor control and minimize probability of normal-tissue complications. For this reason radiation oncology requires high accuracy, which implies no more than 2-3% uncertainty levels in the treatment planning calculations. That is challenging, when heterogeneous tissues such as lungs and bones are involved. To verify the accuracy of the dose calculation algorithms numerous approaches might be performed. The most common are point dose, one-dimensional profile and two-dimensional isodose line comparison with experimental measurements. In presented study, results of transport modeling and the deposited spatial distribution of the dose, obtained by anisotropic analytical algorithm and pencil beam convolution algorithm, were compared to measurements recorded during the experiment. To achieve meaningful conclusions, three parameters: dose difference, distance to agreement and gamma parameter (gamma) were taken into consideration and examined. The irradiation was performed using CIRS anthropomorphic phantom. For dose detection gafchromic EBT films were used and scanned after exposure using Epson Scanner. Measured and planned dose distributions were analyzed via FilmQA software. Preliminary results showed that the anisotropic analytical algorithm, with its complex accounting of heterogeneities, provides more accurate dose calculation within an area of a high density gradient, than pencil beam convolution does. The level of the data accuracy derived from the experiment was: dose difference (5%) - 83.4% and 68% pixels passing, distance to agreement (3 mm) - 99.0% and 96.7%, gamma parameter (for dose difference (3%), distance to agreement (3 mm)) - 90% and 75.5%, respectively, for anisotropic analytical algorithm and pencil beam convolution algorithms. The comparison between studied parameters dose difference, distance to agreement and gamma for both algorithms implicated anisotropic analytical algorithm as an appropriate approach in radiotherapy treatment planning.
引用
收藏
页码:219 / 221
页数:3
相关论文
共 7 条
[1]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[2]  
[Anonymous], 1976, ICRU Report 24
[3]   The choice of statistical methods for comparisons of dosimetric data in radiotherapy [J].
Chaikh, Abdulhamid ;
Giraud, Jean-Yves ;
Perrin, Emmanuel ;
Bresciani, Jean-Pierre ;
Balosso, Jacques .
RADIATION ONCOLOGY, 2014, 9
[4]   Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations [J].
Gagne, Isabelle Marie ;
Zavgorodni, Sergei .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01) :33-46
[5]   A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations [J].
Ulmer, W ;
Pyyry, J ;
Kaissl, W .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1767-1790
[6]   Testing of the analytical anisotropic algorithm for photon dose calculation [J].
Van Esch, Ann ;
Tillikainen, Laura ;
Pyykkonen, Jukka ;
Tenhunen, Mikko ;
Helminen, Hannu ;
Siljamaki, Sami ;
Alakuijala, Jyrki ;
Paiusco, Marta ;
Iori, Mauro ;
Huyskens, Dominique P. .
MEDICAL PHYSICS, 2006, 33 (11) :4130-4148
[7]   A clinical study of lung cancer dose calculation accuracy with Monte Carlo simulation [J].
Zhao, Yanqun ;
Qi, Guohai ;
Yin, Gang ;
Wang, Xianliang ;
Wang, Pei ;
Li, Jian ;
Xiao, Mingyong ;
Li, Jie ;
Kang, Shengwei ;
Liao, Xiongfei .
RADIATION ONCOLOGY, 2014, 9