RADON EXHALATION RATES FROM BUILDING MATERIALS USING ELECTRET ION CHAMBER RADON MONITORS IN ACCUMULATORS

被引:14
|
作者
Kotrappa, Payasada [1 ]
Stieff, Frederick [1 ]
机构
[1] Rad Elec Inc, Frederick, MD 21704 USA
来源
HEALTH PHYSICS | 2009年 / 97卷 / 02期
关键词
electrets; ionization chambers; radon; exhalation rate; EMANATION; DETECTORS; RN-222;
D O I
10.1097/HP.0b013e3181a9ab15
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An electret ion chamber (EIC) radon monitor in a sealed accumulator measures the integrated average radon concentration at the end of the accumulation duration. Theoretical equations have been derived to relate such radon concentrations (Bq m(-3)) to the radon emanation rate (Bq d(-1)) from building materials enclosed in the accumulator. As an illustration, a 4-L sealable glass jar has been used as an accumulator to calculate the radon emanation rate from different granite samples. The radon emanation rate was converted into radon flux (Bq m(-2) d(-1)) by dividing the emanation rate by surface area of the sample. Fluxes measured on typical, commercially available granites ranged from 20-30 Bq m(-2) d(-1). These results are similar to the results reported in the literature. The lower limit or detection for a 2(-d) measurement works out to be 7 Bq m(-2) d(-1). Equations derived can also be used for other sealable accumulators and other integrating detectors, such as alpha track detectors. Health Phys. 97(2):163-166; 2009
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
  • [31] Radionuclide content in some building materials and their radon exhalation
    Holy, K.
    Sykora, I.
    Chudy, M.
    Polaskova, A.
    Journal of Radioanalytical and Nuclear Chemistry, 199 (04):
  • [32] Evaluation of the effect of cover layer on radon exhalation from building materials
    Wang, Chenhua
    Xie, Dong
    Yu, Chuck Wah
    Wang, Hanqing
    INDOOR AND BUILT ENVIRONMENT, 2021, 30 (09) : 1390 - 1399
  • [33] Comparative analysis of techniques for estimating radon exhalation from building materials
    Moreno, P.
    Noverques, A.
    Juste, B.
    Sancho, M.
    Verdu, G.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [34] NATURAL RADIOACTIVITY IN AND RADON EXHALATION FROM FINNISH BUILDING-MATERIALS
    MUSTONEN, R
    HEALTH PHYSICS, 1984, 46 (06): : 1195 - 1203
  • [35] MEASUREMENT OF RADON EXHALATION RATE FROM SOME BUILDING-MATERIALS
    KHAN, AJ
    PRASAD, R
    TYAGI, RK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 609 - 610
  • [36] STATISTICAL MODEL OF QUALITY OF RADON MEASUREMENTS USING ELECTRET ION CHAMBER DETECTORS
    Dubcakova, R.
    Praks, P.
    Moucka, L.
    RADIATION PROTECTION DOSIMETRY, 2011, 145 (2-3) : 295 - 299
  • [37] ASSESSMENT OF RADIUM ACTIVITY CONCENTRATION AND RADON EXHALATION RATES IN IBERIAN PENINSULA BUILDING MATERIALS
    Andrade, E.
    Miro, C.
    Reis, M.
    Santos, M.
    Madruga, M. J.
    RADIATION PROTECTION DOSIMETRY, 2017, 177 (1-2) : 31 - 35
  • [38] Natural radionuclides contents and radon exhalation rates in building materials used in South Korea
    Lee, SC
    Kim, CK
    Lee, DM
    Kang, HD
    RADIATION PROTECTION DOSIMETRY, 2001, 94 (03) : 269 - 274
  • [39] Study on a new charcoal closed chamber method for measuring radon exhalation rate of building materials
    Song Yanchao
    Wang Junlin
    Shang Bing
    Cui Hongxing
    Wu Yunyun
    RADIATION MEASUREMENTS, 2020, 134
  • [40] Surface Radon Exhalation Rates of Building Material and Soil Affect on Indoor Air Radon Concentration
    He Xiaofeng
    Wang Guosheng
    SECOND SREE CONFERENCE ON CHEMICAL ENGINEERING (CCE 2011), 2011, 18