RADON EXHALATION RATES FROM BUILDING MATERIALS USING ELECTRET ION CHAMBER RADON MONITORS IN ACCUMULATORS

被引:14
作者
Kotrappa, Payasada [1 ]
Stieff, Frederick [1 ]
机构
[1] Rad Elec Inc, Frederick, MD 21704 USA
来源
HEALTH PHYSICS | 2009年 / 97卷 / 02期
关键词
electrets; ionization chambers; radon; exhalation rate; EMANATION; DETECTORS; RN-222;
D O I
10.1097/HP.0b013e3181a9ab15
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An electret ion chamber (EIC) radon monitor in a sealed accumulator measures the integrated average radon concentration at the end of the accumulation duration. Theoretical equations have been derived to relate such radon concentrations (Bq m(-3)) to the radon emanation rate (Bq d(-1)) from building materials enclosed in the accumulator. As an illustration, a 4-L sealable glass jar has been used as an accumulator to calculate the radon emanation rate from different granite samples. The radon emanation rate was converted into radon flux (Bq m(-2) d(-1)) by dividing the emanation rate by surface area of the sample. Fluxes measured on typical, commercially available granites ranged from 20-30 Bq m(-2) d(-1). These results are similar to the results reported in the literature. The lower limit or detection for a 2(-d) measurement works out to be 7 Bq m(-2) d(-1). Equations derived can also be used for other sealable accumulators and other integrating detectors, such as alpha track detectors. Health Phys. 97(2):163-166; 2009
引用
收藏
页码:163 / 166
页数:4
相关论文
共 50 条
[31]   Radon Exhalation Rate from Building Materials Using CR-39 Nuclear Track Detector [J].
Topcu, N. ;
Bicak, D. ;
Cam, S. ;
Erees, F. S. .
INDOOR AND BUILT ENVIRONMENT, 2013, 22 (02) :384-387
[32]   Radon exhalation rate in south-east Sicily building materials [J].
D. Morelli ;
R. Catalano ;
R. Filincieri ;
G. Immé ;
G. Mangano .
The European Physical Journal Special Topics, 2015, 224 :605-610
[33]   Building materials radon exhalation rate: ERRICCA intercomparison exercise results [J].
Petropoulos, NP ;
Anagnostakis, MJ ;
Simopoulos, SE .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 272 (1-3) :109-118
[34]   Study of the use of wallpaper to mitigate radon exhalation from building materials in indoor spaces [J].
Ruvira, B. ;
Garcia-Fayos, B. ;
Garcia-Gimeno, B. ;
Arnal, J. M. ;
Verdu, G. .
RADIATION PHYSICS AND CHEMISTRY, 2024, 223
[35]   Estimation of radionuclides content and radon-thoron exhalation from commonly used building materials in India [J].
Kumar, Amit ;
Chauhan, R. P. ;
Joshi, Manish ;
Prajith, Rama ;
Sahoo, B. K. .
ENVIRONMENTAL EARTH SCIENCES, 2015, 74 (02) :1539-1546
[36]   A simple technique for studying the dependence of radon and thoron exhalation rate from building materials on absolute humidity [J].
Nabil M. Hassan ;
Shinji Tokonami ;
Masahiro Fukushi .
Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 :185-191
[37]   Radon exhalation rates and gamma doses from ceramic tiles [J].
O'Brien, RS ;
Aral, H ;
Peggie, JR .
HEALTH PHYSICS, 1998, 75 (06) :630-639
[38]   Indoor radon in dwellings of Jeddah city, Saudi Arabia and its correlations with the radium and radon exhalation rates from soil [J].
Farid, S. M. .
INDOOR AND BUILT ENVIRONMENT, 2016, 25 (01) :269-278
[39]   Studying radon exhalation rates variability from phosphogypsum piles in the SW of Spain [J].
Lopez-Coto, I. ;
Mas, J. L. ;
Vargas, A. ;
Bolivar, J. P. .
JOURNAL OF HAZARDOUS MATERIALS, 2014, 280 :464-471
[40]   Radon and thoron exhalation rate, emanation factor and radioactivity risks of building materials of the Iberian Peninsula [J].
Frutos-Puerto, Samuel ;
Pinilla-Gil, Eduardo ;
Andrade, Eva ;
Reis, Mario ;
Madruga, Maria Jose ;
Miro Rodriguez, Conrado .
PEERJ, 2020, 8