A Hybrid Electronic Nose and Tongue for the Detection of Ketones: Improved Sensor Orthogonality Using Graphene Oxide-Based Detectors

被引:28
作者
Cavallari, Marco R. [1 ,2 ]
Braga, Guilherme S. [3 ]
da Silva, Mauro F. P. [3 ,4 ]
Izquierdo, Jose E. E. [3 ]
Paterno, Leonardo G. [5 ]
Dirani, Ely A. T. [6 ]
Kymissis, Ioannis [1 ]
Fonseca, Fernando J. [3 ]
机构
[1] Columbia Univ, Dept Elect Engn, New York, NY 10027 USA
[2] Escola Politecn Univ Sao Paulo, Dept Engenharia Sistemas Eletronicos, BR-05424970 Sao Paulo, Brazil
[3] Escola Politecn Univ Sao Paulo, BR-05424970 Sao Paulo, Brazil
[4] Pontificia Univ Catolica Sao Paulo, Dept Engenharia, BR-01303050 Sao Paulo, Brazil
[5] Univ Brasilia, Inst Quim, Lab Pesquisa Polimeros & Nanomat, Brasilia, DF, Brazil
[6] Pontificia Univ Catolica Sao Paulo, BR-01303050 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Sensors; graphene; electronic nose; electronic tongue; volatile organic compounds; SENSING PROPERTIES; BREATH ANALYSIS; GAS; AMMONIA; REDUCTION; DIAGNOSIS; PERFORMANCE;
D O I
10.1109/JSEN.2017.2661067
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this contribution, the selectivity toward a diabetes biomarker was demonstrated by a non-specific impedance-metric chemical sensor array from blends of graphene oxide (GO)-based materials as a multivariate system for simultaneous aqueous and gaseous analyte investigation. The electrical impedance of bare graphene either oxidized or after reduction (RGO) displayed high specificity toward ammonia. The sensitivity of GO thin-film capacitance was 10.4 %/ppm of ammonia dissolved in ultrapure water, whereas RGO resistance featured 1.8 %/ppm to gaseous ammonia. However, composites with metal oxides, despite even providing a superior sensitivity to ammonia, completely alter the sign of sensor response to enable distinction of alcohols. Ceria and cyclodextrin allowed GO to operate in air at room temperature with improved stability and a faster response of approximately 60 s. These materials made for an increase in sensitivity to acetone of 11 and 3.2 times, respectively, compared to RGO. Therefore, GO-based composites, as well as the junction of electronic nose and tongue arrays were fundamental to enable the separation of acetone from alcohols and ammonia after principal component analysis.
引用
收藏
页码:1971 / 1980
页数:10
相关论文
共 46 条
[31]   A review of mixed-potential type zirconia-based gas sensors [J].
Miura, Norio ;
Sato, Tomoaki ;
Anggraini, Sri Ayu ;
Ikeda, Hiroshi ;
Zhuiykov, Serge .
IONICS, 2014, 20 (07) :901-925
[32]   Dont waste your breath [J].
Mukhopadhyay, R .
ANALYTICAL CHEMISTRY, 2004, 76 (15) :273A-276A
[33]   Diabetes and contact lens wear [J].
O'donnell, Clare ;
Efron, Nathan .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (03) :328-337
[34]   Impurity level in SnO2 materials and its impact on gas sensing properties [J].
Pavelko, R. G. ;
Yuasa, M. ;
Kida, T. ;
Shimanoe, K. ;
Yamazoe, N. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 :719-725
[35]   A simple visible light photo-assisted method for assembling and curing multilayer GO thin films [J].
Pinheiro da Silva, Mauro Francisco ;
de Oliveira, Debora Rose ;
Cavallari, Marco Roberto ;
Tadeu Dirani, Ely Antonio ;
Triboni, Eduardo Rezende ;
Paterno, Leonardo Giordano ;
Fonseca, Fernando Josepetti ;
Ando, Romulo Augusto ;
Baptista, Mauricio da Silva ;
Landers, Richard ;
Politi, Mario Jose ;
Isolani, Paulo Celso ;
Bernardo Lenz e Silva, Guilherme Frederico .
MATERIALS CHEMISTRY AND PHYSICS, 2015, 165 :125-133
[36]   Synthesis and characterization of CeO2-graphene composite [J].
Pinheiro da Silva, Mauro Francisco ;
de Jesus Fraga da Costa, Heloisa Cristina ;
Triboni, Eduardo Rezende ;
Politi, Mario Jose ;
Isolani, Paulo Celso .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 107 (01) :257-263
[37]   Metal oxide nanowires for chemiresistive gas sensors: Issues, challenges and prospects [J].
Ramgir, Niranjan ;
Datta, Niyanta ;
Kaur, Manmeet ;
Kailasaganapathi, S. ;
Debnath, Anil K. ;
Aswal, D. K. ;
Gupta, S. K. .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 439 :101-116
[38]   STUDY ON A DETECTOR FOR GASEOUS COMPONENTS USING SEMICONDUCTIVE THIN FILMS [J].
SEIYAMA, T ;
KAGAWA, S .
ANALYTICAL CHEMISTRY, 1966, 38 (08) :1069-&
[39]   Flexible NO2 sensors fabricated by layer-by-layer covalent anchoring and in situ reduction of graphene oxide [J].
Su, Pi-Guey ;
Shieh, Hung-Chiang .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 :865-872
[40]   Selective Ion Penetration of Graphene Oxide Membranes [J].
Sun, Pengzhan ;
Zhu, Miao ;
Wang, Kunlin ;
Zhong, Minlin ;
Wei, Jinquan ;
Wu, Dehai ;
Xu, Zhiping ;
Zhu, Hongwei .
ACS NANO, 2013, 7 (01) :428-437