Detection of hydrocarbons using suspended core microstructured optical fiber

被引:12
作者
Martan, T. [1 ]
Aubrecht, J. [1 ]
Podrazky, O. [1 ]
Matejec, Vl. [1 ]
Kasik, I. [1 ]
机构
[1] ASCR, Inst Photon & Elect, Vvi, Prague 18251 8, Czech Republic
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2014年 / 202卷
关键词
Microstructured optical fiber; Suspended core structure; Evanescent wave; Refractive index; Toluene vapors; Detection; QUARTZ-CRYSTAL MICROBALANCE; PHOTONIC BANDGAP FIBER; SENSOR; TOLUENE; WATER; AIR;
D O I
10.1016/j.snb.2014.04.103
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring of dangerous hydrocarbons is an important issue for both chemical process control in industry and protection of the environment. Vapors of toluene are highly dangerous in low concentrations because of its low explosive limit of 1.2 mol%. Toluene vapors in concentrations lower than the explosive limit can be detected using a fiber optic arrangement containing a short section of suspended core microstructured optical fiber (SC MOF). We prepared the SC MOF for this purpose, with an inner structure consisting of a relatively thin silica core, 2.6 mu m in diameter, surrounded by three large cladding holes with radii of 26 mu m, which were designed to be large enough for trouble-free analyte flow. It has been shown that a 0.3 m-long SC MOF sensing element can be used for refractometric detection of toluene vapors in low concentrations without using any other adsorption layers. We have experimentally verified the operational reversibility of the SC MOF sensing element in time. A sensitivity of 1.20 +/- 0.04 dB/mol% and a detection limit of 0.0079 mol% have been determined for this sensing element. The SC MOF can detect sufficiently low concentrations of toluene vapors to reveal safety risks before the toluene reaches the lower explosive limit. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 30 条
[1]   Fibre optical sensor for C2H2 gas using gas-filled photonic bandgap fibre reference cell [J].
Austin, Ed ;
van Brakel, Adriaan ;
Petrovich, Marco N. ;
Richardson, David J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) :30-34
[2]  
Baldini B., 2006, OPTICAL CHEM SENSORS
[3]  
Bennett K., 2007, P SOC PHOTO-OPT INS, V6770
[4]   Developmental neurotoxicity of toluene: in vivo and in vitro effects on astroglial cells [J].
Burry, M ;
Guizzetti, M ;
Oberdoerster, J ;
Costa, LG .
DEVELOPMENTAL NEUROSCIENCE, 2003, 25 (01) :14-19
[5]   Detection of aromatic hydrocarbons in air and water by using xerogel layers coated on PCS fibers excited by an inclined collimated beam [J].
Cherif, K ;
Mrazek, J ;
Hleli, S ;
Matejec, V ;
Abdelghani, A ;
Chomat, M ;
Jaffrezic-Renault, N ;
Kasik, I .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 95 (1-3) :97-106
[6]   Chemical detection in liquid media with a refractometric sensor based on a multimode optical fibre [J].
Cherif, K ;
Hleli, S ;
Abdelghani, A ;
Jaffrezic-Renault, N ;
Matejec, V .
SENSORS, 2002, 2 (06) :195-204
[7]   Optical detection of toluene in water by using IGI fibers [J].
Chomát, M ;
Berková, D ;
Matejec, V ;
Kasík, I ;
Kuncová, G ;
Gagnaire, H ;
Trouillet, A ;
Bardin, F .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2002, 21 (1-2) :211-215
[8]   Optical detection of toluene in water using an IGI optical fiber with a short sensing region [J].
Chomat, M ;
Berkova, D ;
Matejec, V ;
Kasik, I ;
Kuncova, G ;
Hayer, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) :258-267
[9]   Methane detection at 1670-nm band using a hollow-core photonic bandgap fiber and a multiline algorithm [J].
Cubillas, A. M. ;
Silva-Lopez, M. ;
Lazaro, J. M. ;
Conde, O. M. ;
Petrovich, M. N. ;
Lopez-Higuera, J. M. .
OPTICS EXPRESS, 2007, 15 (26) :17570-17576
[10]  
DEAN JA, 1992, LANGE HDB CHEM