Evaluation of Commercial Glucometer Test Strips for Potential Measurement of Glucose in Tears

被引:52
作者
Cha, Kyoung Ha [1 ]
Jensen, Gary C. [1 ]
Balijepalli, Anant S. [1 ]
Cohan, Bruce E. [2 ]
Meyerhoff, Mark E. [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] EyeLab Grp LLC, Ann Arbor, MI 48104 USA
关键词
DEHYDROGENASE; SENSORS; FLUID;
D O I
10.1021/ac4040168
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tear glucose measurements have been suggested as a potential alternative to blood glucose monitoring for diabetic patients. While previous work has reported that there is a correlation between blood and tear glucose levels in humans, this link has not been thoroughly established and additional clinical studies are needed. Herein, we evaluate the potential of using commercial blood glucose test strips to measure glucose in tears. Of several blood glucose strips evaluated, only one brand exhibits the low detection limit required for quantitating glucose in tears. Calibration of these strips in the range of 0-100 mu M glucose with an applied potential of 150 mV to the working electrode yields a sensitivity of 0.127 nA/mu M and a limit of quantitation (LOQ) of 9 mu M. The strips also exhibit <= 13% error (n = 3) for 25, 50, and 75 mu M glucose in the presence of 10 mu M acetaminophen, 100 mu M ascorbic acid, and 100 mu M uric acid. Measurements of glucose in tears from nine normal (nondiabetic) fasting human subjects using strips yielded glucose values within the range of 5-148 mu M (mean = 47 mu M, median = 43 mu M), similar to those for human tears reported by others with more complex LC-MS methods. The glucometer strip method could facilitate more clinical studies to determine whether tear glucose and blood glucose levels sufficiently correlate for application to routine measurements in tears to supplement blood glucose testing. This would be especially helpful for children, adolescents, other Type 1 diabetics, and also for Type 2 diabetics who require treatment with insulin and cannot tolerate multiple finger sticks per day.
引用
收藏
页码:1902 / 1908
页数:7
相关论文
共 37 条
  • [1] Microfluidic Devices Integrating Microcavity Surface-Plasmon-Resonance Sensors: Glucose Oxidase Binding-Activity Detection
    Amarie, Dragos
    Alileche, Abdelkrim
    Dragnea, Bogdan
    Glazier, James A.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (01) : 343 - 352
  • [2] Metal-enhanced fluorescence solution-based sensing platform
    Aslan, K
    Lakowicz, JR
    Szmacinski, H
    Geddes, CD
    [J]. JOURNAL OF FLUORESCENCE, 2004, 14 (06) : 677 - 679
  • [3] Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
    Baca, Justin T.
    Finegold, David N.
    Asher, Sanford A.
    [J]. OCULAR SURFACE, 2007, 5 (04) : 280 - 293
  • [4] Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
    Baca, Justin T.
    Taormina, Christopher R.
    Feingold, Eleanor
    Finegold, David N.
    Grabowski, Joseph J.
    Asher, Sanford A.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (07) : 1370 - 1372
  • [5] A glucose-sensing contact lens: from bench top to patient
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    [J]. CURRENT OPINION IN BIOTECHNOLOGY, 2005, 16 (01) : 100 - 107
  • [6] Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    [J]. TALANTA, 2005, 65 (03) : 762 - 768
  • [7] Ophthalmic glucose monitoring using disposable contact lenses - A review
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    [J]. JOURNAL OF FLUORESCENCE, 2004, 14 (05) : 617 - 633
  • [8] Burke D. W., 2010, U.S. Patent, Patent No. [7,727,467, 7727467]
  • [9] Noninvasive measurement of glucose by metabolic heat conformation method
    Cho, OK
    Kim, YY
    Mitsumaki, H
    Kuwa, K
    [J]. CLINICAL CHEMISTRY, 2004, 50 (10) : 1894 - 1898
  • [10] Choy CKM, 2000, INVEST OPHTH VIS SCI, V41, P3293