The reproducibility and short-term and long-term repeatability of sonographic measurement of splenic length

被引:10
作者
Li, PS [1 ]
Ying, M [1 ]
Chan, KH [1 ]
Chan, PW [1 ]
Chu, KL [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Optometry & Radiog, Kowloon, Hong Kong, Peoples R China
关键词
reproducibility; repeatability; ultrasound; splenic length;
D O I
10.1016/j.ultrasmedbio.2004.05.012
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study was undertaken to evaluate the reproducibility (interobserver variability), and the short-term and long-term repeatability (intraobserver variability) of sonographic measurement of the maximum and mean splenic length. Ultrasound (US) measurements of the splenic length were performed in 43 subjects, ages 30 to 59 years old (mean age = 44.5 years). Each subject attended three US sessions: baseline examination and 30 min and 8 weeks after the baseline examination. In each session, US examinations of the spleen were performed and the splenic length was measured by four operators. In each examination, the splenic length was measured 3 times, and the maximum and mean values were obtained. The overall reproducibility of the measurements of maximum and mean splenic lengths were 67% and 89%, respectively. The short-term repeatability in measuring the maximum and mean splenic lengths were 87% and 94%, respectively, whereas the long-term repeatabilities were 61% and 76%, respectively. The reproducibility and short-term and long-term repeatability of the measurement of mean splenic length were higher than those of the maximum splenic length. In the mean and maximum splenic length measurement, the short-term repeatability was higher than the long-term repeatability. The results suggested that the mean splenic length has a higher reliability in sonographic measurement and should be used in routine clinical practice. Measurement errors should be considered when evaluating the changes of splenic length in serial US examinations, particularly in long-term follow-up. (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:861 / 866
页数:6
相关论文
共 23 条
[1]   HOW RELIABLE ARE ULTRASOUND MEASUREMENTS OF RENAL LENGTH IN ADULTS [J].
ABLETT, MJ ;
COULTHARD, A ;
LEE, REJ ;
RICHARDSON, DL ;
BELLAS, T ;
OWEN, JP ;
KEIR, MJ ;
BUTLER, TJ .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (814) :1087-1089
[2]   Ultrasound of the spleen [J].
Andrews, MW .
WORLD JOURNAL OF SURGERY, 2000, 24 (02) :183-187
[3]   COLOR DOPPLER IMAGING OF THE EYE - NORMAL RANGES, REPRODUCIBILITY, AND OBSERVER VARIATION [J].
BAXTER, GM ;
WILLIAMSON, TH .
JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (02) :91-96
[4]   THE REPEATABILITY AND ACCURACY OF ULTRASOUND IN MEASURING BACKFAT OF CATTLE [J].
BRETHOUR, JR .
JOURNAL OF ANIMAL SCIENCE, 1992, 70 (04) :1039-1044
[5]   Normal splenic volumes estimated using three-dimensional ultrasonography [J].
De Odorico, I ;
Spaulding, KA ;
Pretorius, DH ;
Lev-Toaff, AS ;
Bailey, TB ;
Nelson, TR .
JOURNAL OF ULTRASOUND IN MEDICINE, 1999, 18 (03) :231-236
[6]   Errors in ultrasound digital image distance measurements [J].
Goldstein, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (07) :1125-1132
[7]   CHANGES IN SPLENIC SIZE AFTER ABDOMINAL-TRAUMA [J].
GOODMAN, LR ;
APRAHAMIAN, C .
RADIOLOGY, 1990, 176 (03) :629-632
[8]   SONOGRAPHIC ASSESSMENT AND GRADING OF SPLEEN SIZE [J].
ISHIBASHI, H ;
HIGUCHI, N ;
SHIMAMURA, R ;
HIRATA, Y ;
KUDO, J ;
NIHO, Y .
JOURNAL OF CLINICAL ULTRASOUND, 1991, 19 (01) :21-25
[9]   ONLINE DOPPLER ULTRASOUND MEASUREMENT OF AORTIC COMPLIANCE AND ITS REPEATABILITY IN NORMAL SUBJECTS [J].
KONTIS, S ;
GOSLING, RG .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (02) :127-135
[10]   Spleen size: how well do linear ultrasound measurements correlate with three-dimensional CT volume assessments? [J].
Lamb, PM ;
Lund, A ;
Kanagasabay, RR ;
Martin, A ;
Webb, JAW ;
Reznek, RH .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (895) :573-577