A Selective and Sensitive Gas Chromatography-Tandem Mass Spectrometry Method for Quantitation of Synthetic Musks in Human Serum

被引:6
|
作者
Katuri, Guru Prasad [1 ]
Fan, Xinghua [1 ]
Siddique, Shabana [1 ]
Kubwabo, Cariton [1 ]
Kosarac, Ivana [2 ]
Harris, Shelley A. [3 ]
Foster, Warren G. [4 ]
机构
[1] Hlth Canada, Environm Hlth Sci & Res Bur, Ottawa, ON, Canada
[2] Hlth Canada, Tobacco Control Directorate, Off Res & Surveillance, Ottawa, ON, Canada
[3] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[4] McMaster Univ, Dept Obstet & Gynecol, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HUMAN BREAST-MILK; UMBILICAL-CORD BLOOD; POLYCYCLIC MUSKS; FRAGRANCES; SAMPLES; XYLENE; WATER; FISH; MICROEXTRACTION; EXTRACTION;
D O I
10.1093/jaoacint/qsaa051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Synthetic musk compounds are widely used as fragrances in many consumer products; however, information co on human exposure and health effects is limited. Also, analytical methods for their quantification in biological matrices are limited. Objective: In this study, an integrated method was developed and validated for the analysis of selected synthetic musk compounds in human serum. Method: The method is based on liquid-liquid extraction (LLE), sample clean-up by solid-phase extraction (SPE), and separation and detection by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). Results: The method demonstrated good recoveries (86-105%) and high sensitivity, with low method detection limits (MDLs) ranging from 0.04 to 0.17 mu g/L. The method was applied to the analysis of 10 synthetic musk compounds in 40 serum samples collected from Canadian women aged 20-44 years (20 individual samples collected in 2014 and 20 pooled samples collected in 2006). The most commonly detected compound was Galaxolide (HHCB), with median concentrations of 0.59 mu g/L in samples collected in 2006, and 0.34 mu g/L for samples collected in 2014. Musk ketone (MK) was not detected in any of the samples collected in 2006, but was detected in 60% of the samples collected in 2014 with a median concentration of 0.29 mu g/L. Tonalide (AHTN) was detected in only one sample above its MDL (0.12 mu g/L). Conclusions: This is the first study in Canada to report levels of synthetic musks in human. The data generated from this 3 study has been used in risk screening assessment by Environment and Climate Change Canada and Health Canada.
引用
收藏
页码:1461 / 1468
页数:8
相关论文
共 50 条
  • [21] Development of an Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for the Analysis of Perfluorinated Compounds in Fish and Fatty Food
    Chung, Stephen W. C.
    Lam, Chi Ho
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (25) : 5805 - 5811
  • [22] Selective and Sensitive Quantification of Acetochlor and S-Metolachlor in Maize and Soybean Plant Samples by Gas Chromatography-Tandem Mass Spectrometry
    Cara, Irina Gabriela
    Topa, Denis
    Raus, Lucian
    Calistru, Anca Elena
    Filipov, Feodor
    Jitareanu, Gerard
    AGRICULTURE-BASEL, 2021, 11 (04):
  • [23] Determination of Emerging Contaminants in Cereals by Gas Chromatography-Tandem Mass Spectrometry
    Albero, Beatriz
    Luis Tadeo, Jose
    Ana Perez, Rosa
    FRONTIERS IN CHEMISTRY, 2020, 8
  • [24] Validation of an ultra high performance liquid chromatography-tandem mass spectrometry method for detection and quantitation of 19 endocrine disruptors in milk
    Wielogorska, E.
    Elliott, C. T.
    Danaher, M.
    Chevallier, O.
    Connolly, L.
    FOOD CONTROL, 2015, 48 : 48 - 55
  • [25] Simultaneous determination of polycyclic musks in blood and urine by solid supported liquid-liquid extraction and gas chromatography-tandem mass spectrometry
    Liu, Hongtao
    Huang, Liping
    Chen, Yuxin
    Guo, Liman
    Li, Limin
    Zhou, Haiyun
    Luan, Tiangang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 992 : 96 - 102
  • [26] Accurate quantitation of choline and ethanolamine plasmalogen molecular species in human plasma by liquid chromatography-tandem mass spectrometry
    Otoki, Yurika
    Kato, Shunji
    Kimura, Fumiko
    Furukawa, Katsutoshi
    Yamashita, Shinji
    Arai, Hiroyuki
    Miyazawa, Teruo
    Nakagawa, Kiyotaka
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 77 - 85
  • [27] Miniaturized extraction method for analysis of synthetic opioids in urine by microextraction with packed sorbent and liquid chromatography-tandem mass spectrometry
    da Cunha, Kelly Francisco
    Rodrigues, Leonardo Costalonga
    Huestis, Marilyn A.
    Costa, Jose Luiz
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624
  • [28] A rapid and fully-automated method for the quantitation of tricyclic antidepressants in serum using turbulent-flow liquid chromatography-tandem mass spectrometry
    Breaud, Autumn R.
    Harlan, Robert
    Di Bussolo, Joseph M.
    McMillin, Gwendolyn A.
    Clarke, William
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 825 - 832
  • [29] Simultaneous quantification of 37 synthetic cannabinoid metabolites in human urine by liquid chromatography-tandem mass spectrometry
    Jang, Moonhee
    Shin, Ilchung
    Kim, Jihyun
    Yang, Wonkyung
    FORENSIC TOXICOLOGY, 2015, 33 (02) : 221 - 234
  • [30] MASS SPECTRAL FRAGMENTATION PATHWAYS OF PHTHALATE ESTERS BY GAS CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Yin, Peng
    Chen, Hongping
    Liu, Xin
    Wang, Qinghua
    Jiang, Ying
    Pan, Rong
    ANALYTICAL LETTERS, 2014, 47 (09) : 1579 - 1588