Design and evaluation of a shunted flexible piezoelectric damper for vibration control of cable structures

被引:9
|
作者
Xie, Fei [1 ]
Su, Yu [1 ]
Zhou, Wei [1 ]
Zhang, Wei-Zhong [2 ]
机构
[1] Beijing Inst Technol, Sch Aerosp Engn, Dept Mech, Beijing 100081, Peoples R China
[2] Beijing Inst Technol, Sch Aerosp Engn, Minist Educ, Key Lab Dynam & Control Flight Vehicles, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
vibration control; piezoelectric; flexible cable structure; shunt circuit; POSITIVE POSITION FEEDBACK; NET STRUCTURES; NEGATIVE CAPACITANCES; RL SHUNTS; ENHANCEMENT; SUPPRESSION; CALIBRATION;
D O I
10.1088/1361-665X/ab2c14
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this work a shunted flexible piezoelectric damping system is designed and numerically evaluated for the purpose of vibration attenuation of large deployable space cable structures. We propose a design of a tube-shaped flexible piezoelectric energy absorber consisting of multilayered PVDF sectors, which could be shunted with two types of passive electric circuits, i.e. the series resistance-inductance (LR) shunt and the series resistance-negative capacitance (NC-R) shunt. The compatible stiffness of the PVDF tube ensures an effective transformation of deformation from the vibrating cable to the energy absorber. For best performance we carried out optimization on the geometric parameters of the PVDF tube. By analysis we found that the optimal thickness of the PVDF tube is roughly 0.4 times of the inner tube radius. We optimized the shunt circuits and selected the appropriate distribution position of the damper in the flexible cable structures. The performance of the design was numerically evaluated based on three problems, namely the longitudinal vibration of a single-cable structure, the transverse vibration of a single-cable structure and the vibration of a cross-cable structure. Based on the results, we confirm the remarkable performance of the design. Being highly frequency dependent, the design with the LR shunt only works for one deformation mode at a time, e.g. bending or stretching. In contrast, the design with the NC-R shunt works for both modes as it has a much wider frequency band. The design with the LR shunt has better performance than the NC-R shunt when dealing with the stretching deformation mode only. For vibration with combined stretching and bending, however, the performance of both designs is equally good. This is because the NC-R shunt can work for both deformation modes simultaneously, and hence it shows great adaptability and application potential in vibration control of complex flexible space structures.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A survey of recent innovations in vibration damping and control using shunted piezoelectric transducers
    Moheimani, SOR
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2003, 11 (04) : 482 - 494
  • [22] Modal-based model reduction and vibration control for uncertain piezoelectric flexible structures
    Yalan, Xu
    Jianjun, Chen
    STRUCTURAL ENGINEERING AND MECHANICS, 2008, 29 (05) : 489 - 504
  • [23] Vibration control of a stay cable with a rotary electromagnetic inertial mass damper
    Wang, Zhi Hao
    Xu, Yan Wei
    Gao, Hui
    Chen, Zheng Qing
    Xu, Kai
    Zhao, Shun Bo
    SMART STRUCTURES AND SYSTEMS, 2019, 23 (06) : 627 - 639
  • [24] Study on Vibration Control of Long Cable with Shape Memory Alloy Damper
    Liu, Ai-Rong
    Yu, Qi-Cai
    Zhang, Jun-Ping
    Xie, Sheng-Fen
    Guo, Yu-Zhu
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 3023 - 3026
  • [25] Modified liquid column damper for vibration control of structures
    Al-Saif, K. A.
    Aldakkan, K. A.
    Foda, M. A.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2011, 53 (07) : 505 - 512
  • [26] Negative derivative feedback for vibration control of flexible structures
    Cazzulani, G.
    Resta, F.
    Ripamonti, F.
    Zanzi, R.
    SMART MATERIALS AND STRUCTURES, 2012, 21 (07)
  • [27] Adaptive MR damper cable control system based on piezoelectric power harvesting
    Guan, Xinchun
    Huang, Yonghu
    Li, Hui
    Ou, Jinping
    SMART STRUCTURES AND SYSTEMS, 2012, 10 (01) : 33 - 46
  • [28] Passive Shunted Piezoelectric Systems for Vibration Control of Wind Turbine Towers: A Feasibility Study
    Daraki, Maria-Styliani
    Marakakis, Konstantinos
    Alevras, Panagiotis
    Foutsitzi, Georgia A.
    Stavroulakis, Georgios E.
    ENERGIES, 2024, 17 (10)
  • [29] Control-structural design optimization for vibration of piezoelectric intelligent truss structures
    Zhao, Guozhong
    Chen, Biaosong
    Gu, Yuanxian
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2009, 37 (05) : 509 - 519
  • [30] Vibration Control by Means of Piezoelectric Actuators Shunted with LR Impedances: Performance and Robustness Analysis
    Berardengo, M.
    Cigada, A.
    Manzoni, S.
    Vanali, M.
    SHOCK AND VIBRATION, 2015, 2015