Understanding the influence of three-dimensional sidewall roughness on observed line-edge roughness in scanning electron microscopy images

被引:3
|
作者
van Kessel, Luc [1 ]
Huisman, Thomas [2 ]
Hagen, Cornelis W. [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Delft, Netherlands
[2] ASML Netherlands BV, Veldhoven, Netherlands
来源
JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS | 2020年 / 19卷 / 03期
关键词
scanning electron microscopy; line edge roughness; sidewall roughness; metrology; Monte Carlo methods; SCATTERING; SURFACES; MODEL; SEM;
D O I
10.1117/1.JMM.19.3.034002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Background: Line-edge roughness (LER) is often measured from top-down critical dimension scanning electron microscope (CD-SEM) images. The true three-dimensional roughness profile of the sidewall is typically ignored in such analyses. Aim: We study the response of a CD-SEM to sidewall roughness (SWR) by simulation. Approach: We generate random rough lines and spaces, where the SWR is modeled by a known power spectral density. We then obtain corresponding CD-SEM images using a Monte Carlo electron scattering simulator. We find the measured LER from these images and compare it to the known input roughness. Results: For isolated lines, the SEM measures the outermost extrusion of the rough sidewall. The result is that the measured LER is up to a factor of 2 less than the true on-wafer roughness. The effect can be modeled by making a top-down projection of the rough edge. Our model for isolated lines works fairly well for a dense grating of lines and spaces as long as the trench width exceeds the line height. Conclusions: In order to obtain and compare accurate LER values, the projection effect of SWR needs to be taken into account. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Effects of image noise on contact edge roughness and critical dimension uniformity measurement in synthesized scanning electron microscope images
    Constantoudis, Vassilios
    Kuppuswamy, Vijaya-Kumar Murugesan
    Gogolides, Evangelos
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2013, 12 (01):
  • [22] Three-dimensional scanning electron microscopy of maxillofacial biomaterials
    Pabst, A. M.
    Mueller, W. E. G.
    Ackermann, M.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2017, 55 (07) : 736 - 739
  • [23] Atomic force microscopy study of photoresist sidewall smoothing and line edge roughness transfer during gate patterning
    Fouchier, Marc
    Pargon, Erwine
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2013, 12 (04):
  • [24] Electron-beam nanolithography and line-edge roughness of acid-breakable resin-based positive resist
    Sakamizu, T
    Shiraishi, H
    MICROELECTRONIC ENGINEERING, 2002, 61-2 : 763 - 770
  • [25] Characterization of the shape and line-edge roughness of polymer gratings with grazing incidence small-angle X-ray scattering and atomic force microscopy
    Suh, Hyo Seon
    Chen, Xuanxuan
    Rincon-Delgadillo, Paulina A.
    Jiang, Zhang
    Strzalka, Joseph
    Wang, Jin
    Chen, Wei
    Gronheid, Roel
    de Pablo, Juan J.
    Ferrier, Nicola
    Doxastakis, Manolis
    Nealey, Paul F.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2016, 49 : 823 - 834
  • [26] Unbiased line width roughness measurements with critical dimension scanning electron microscopy and critical dimension atomic force microscopy
    Azarnouche, L.
    Pargon, E.
    Menguelti, K.
    Fouchier, M.
    Fuard, D.
    Gouraud, P.
    Verove, C.
    Joubert, O.
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (08)
  • [27] The three-dimensional architecture of the myosalpinx in the cow as revealed by scanning electron microscopy
    Muglia, U
    Germana, A
    Abbate, F
    Germana, G
    Motta, PM
    JOURNAL OF SUBMICROSCOPIC CYTOLOGY AND PATHOLOGY, 1997, 29 (02) : 201 - 207
  • [28] Three-dimensional architecture of the myosalpinx in the mare as revealed by scanning electron microscopy
    Germanà, A
    Cassata, R
    Cristarella, S
    Scirpo, A
    Muglia, U
    ANATOMICAL RECORD, 2002, 267 (03): : 235 - 241
  • [29] Validation of three-dimensional surface characterising methods:: Scanning electron microscopy and confocal laser scanning microscopy
    Al-Nawas, B
    Grötz, KA
    Götz, H
    Heinrich, G
    Rippin, G
    Stender, E
    Duschner, H
    Wagner, W
    SCANNING, 2001, 23 (04) : 227 - 231
  • [30] Three-dimensional simulation of the effect of e-beam lithography induced line-edge roughness on n-type metal-oxide-semiconductor transistor electrical characteristics for a 50 nm technology
    Scheiblin, P