Implementation of the HbA1c IFCC unit - from the laboratory to the consumer: The New Zealand experience

被引:2
|
作者
Florkowski, Christopher [1 ]
Crooke, Michael [2 ,3 ]
Reed, Maxine [3 ]
机构
[1] Canterbury Hlth Labs, Christchurch, New Zealand
[2] Wellington Hosp, Wellington, New Zealand
[3] Aotea Pathol, Wellington, New Zealand
关键词
Harmonisation; HbA1c; Diabetes; AVERAGE GLUCOSE; STANDARDIZATION; SYSTEM;
D O I
10.1016/j.cca.2013.10.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In 2007, an international consensus statement recommended that HbA1c results should be reported world-wide in IFCC units (mmol/mol) and also the more familiar derived percentage units using a master equation. In New Zealand, the HbA1c IFCC units have been successfully implemented and used exclusively since 3rd October 2011 (following a 2year period of reporting both units) for both patient monitoring and the diagnosis of diabetes, with a diagnostic cut-off of >= 50 mmol/mol. The consultation process in New Zealand dates back to 2003, well before the international recommendations were made. It reflects the close cooperation between the clinical and laboratory communities in New Zealand, particularly through the agency of the New Zealand Society for the Study of Diabetes (NZSSD), a key organisation in New Zealand open to all those involved in the care of people with diabetes and the national advisory body on scientific and clinical diabetes care and standards. There was a phased process of consultation designed to increase familiarity and comfort with the new units and the final step was coupled with the adoption of HbA1c as a diagnostic test with some evidence-based pragmatism around using the rounded cut-off. Genuine clinical engagement is vital in such a process. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 161
页数:5
相关论文
共 50 条
  • [31] HbA1c in adults without known diabetes from southern Europe. Impact of the new diagnostic criteria in clinical practice
    Bernal-Lopez, M. R.
    Santamaria-Fernandez, S.
    Lopez-Carmona, D.
    Tinahones, F. J.
    Mancera-Romero, J.
    Pena-Jimenez, D.
    Jansen-Chaparro, S.
    Baca-Osorio, A. J.
    Cuesta-Munoz, A. L.
    Serrano-Rios, M.
    Gomez-Huelgas, R.
    DIABETIC MEDICINE, 2011, 28 (11) : 1319 - 1322
  • [32] Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decade
    Selvin, E
    Coresh, J
    Jordahl, J
    Boland, L
    Steffes, MW
    DIABETIC MEDICINE, 2005, 22 (12) : 1726 - 1730
  • [33] Measurement of HbA1c from stored whole blood samples in the Atherosclerosis Risk in Communities study
    Selvin, Elizabeth
    Coresh, Josef
    Zhu, Hong
    Folsom, Aaron
    Steffes, Michael W.
    JOURNAL OF DIABETES, 2010, 2 (02) : 118 - 124
  • [34] Implementation of point-of-care HbA1C instruments into community pharmacies: Initial development of a pathway for robust community testing
    Radley, Andrew
    Beer, Lewis
    Rushdi, Danya
    Close, Hazel
    Mcburney, Stephen
    Mackenzie, Adrian
    Gourlay, Anna
    Barnett, Anna
    Grant, Alison
    Greig, Neil
    Dow, Ellie
    Sutherland, Calum
    ANNALS OF CLINICAL BIOCHEMISTRY, 2024, 61 (04) : 273 - 283
  • [35] Relationship of HbA1C to blood glucose concentrations in children with type 1 diabetes mellitus from Eastern India
    Gaikwad, Prashant Manohar
    Hathi, Deep
    Goswami, Soumik
    Sengupta, Nilanjan
    Baidya, Arjun
    Das, Niladri
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2024,
  • [36] A step towards optimal efficiency of HbA1c measurement as a first-line laboratory test: the TOP-HOLE (Towards OPtimal glycoHemOgLobin tEsting) project
    Pasqualetti, Sara
    Carnevale, Assunta
    Dolci, Alberto
    Panteghini, Mauro
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (03) : 441 - 450
  • [37] HbA1c screening for new onset diabetes following acute coronary syndrome: Is it a worthwhile test in clinical practice?
    Lugg S.T.
    May C.J.H.
    Nightingale P.
    Tuffley R.P.E.
    Al-Hourani J.
    De P.
    Journal of Diabetes & Metabolic Disorders, 16 (1)
  • [38] Study of HbA1c levels in non-diabetic individuals recovered from Covid-19
    Gandikota, Sainithesh
    Sudha, Kothapalle Sowmya
    Naramalli, Madhavi Latha
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2023, 12 (11) : 2727 - 2732
  • [39] Performance Evaluation of a New Fluorescent-Based Lateral Flow Immunoassay for Quantification of Hemoglobin A1c (HBA1c) in Diabetic Patients
    Younes, Nadin
    Ghwairi, Mahmoud M. Al
    Da'as, Sahar Isa
    Al Zaabi, Eiman
    Majdalawieh, Amin F.
    Al-Dewik, Nader
    Nasrallah, Gheyath K.
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2023, 28 (03):
  • [40] First evaluation of Capillarys 2 Flex Piercing® (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis
    Jaisson, Stephane
    Leroy, Nathalie
    Meurice, Julie
    Guillard, Emmanuelle
    Gillery, Philippe
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (10) : 1769 - 1775