Accurate determination and certification of bromine in plastic by isotope dilution inductively coupled plasma mass spectrometry

被引:21
作者
Ohata, Masaki [1 ]
Miura, Tsutomu [1 ]
机构
[1] Natl Metrol Inst Japan, Inorgan Analyt Chem Div, Inorgan Stand Sect, Tsukuba, Ibaraki 3058563, Japan
关键词
Isotope dilution inductively coupled plasma; mass spectrometry (ID-ICPMS); Bromine analysis in plastic; Microwave acid digestion procedure; Memory effect; Certified reference material (CRM); RoHS directive; CERTIFIED REFERENCE MATERIALS; HEAVY-METAL ANALYSIS; ICP-MS; ORGANIC-COMPOUNDS; HALOGENS; UNCERTAINTY; RESPECT; SAMPLES; SULFUR; LEAD;
D O I
10.1016/j.aca.2014.06.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH3) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH3 solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 41 条
  • [31] Nelm S.M., 2005, ICP MASS SPECTROMETR
  • [32] Simultaneous determination of fluorine, chlorine and bromine in cement with ion chromatography after pyrolysis
    Noguchi, Yasunari
    Zhang, Liang
    Maruta, Toshihisa
    Yamane, Takeshi
    Kiba, Nobutoshi
    [J]. ANALYTICA CHIMICA ACTA, 2009, 640 (1-2) : 106 - 109
  • [33] Characterization of inorganic components in plastic materials
    Nomura, DH
    Mateus, SF
    Saiki, M
    Bode, P
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (01) : 61 - 65
  • [34] Development of ABS resin pellet certified reference materials for heavy metal analysis with respect to RoHS directive
    Ohata, Masaki
    Kurahashi, Masayasu
    Hioki, Akiharu
    [J]. BUNSEKI KAGAKU, 2008, 57 (06) : 417 - 426
  • [35] Development of PVC and PP Resin Pellet Certified Reference Materials for Heavy Metal Analysis with Respect to the RoHS Directive
    Ohata, Masaki
    Hioki, Akiharu
    [J]. ANALYTICAL SCIENCES, 2013, 29 (02) : 239 - 246
  • [36] Identification of Flame Retardants in Polyurethane Foam Collected from Baby Products
    Stapleton, Heather M.
    Klosterhaus, Susan
    Keller, Alex
    Ferguson, P. Lee
    van Bergen, Saskia
    Cooper, Ellen
    Webster, Thomas F.
    Blum, Arlene
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (12) : 5323 - 5331
  • [37] Van Borm W, 1999, FRESEN J ANAL CHEM, V365, P361
  • [38] Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM) project using isotope dilution mass spectrometry
    Vogl, J
    Liesegang, D
    Ostermann, M
    Diemer, J
    Berglund, M
    Quétel, CR
    Taylor, PDP
    Heumann, KG
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2000, 5 (08) : 314 - 324
  • [39] Isotope Dilution Mass Spectrometry - A Primary Method of Measurement and Its Role for RM Certification
    Vogl, Jochen
    Pritzkow, Wolfgang
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2010, 25 (03): : 135 - 164
  • [40] Hazardous and other element characterization of new and used domestic plastic food containers using INAA and AAS
    Waheed, S.
    Rahman, S.
    Husnain, S. M.
    Siddique, N.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 292 (03) : 937 - 945