Assessment of Left Atrial Function Using Multi-Slice CT Images

被引:8
作者
Hu, W. C. [1 ]
Wu, M. H. [1 ]
Tsao, H. M. [3 ]
Lin, C. C. [2 ]
Shyu, L. Y. [1 ]
Wang, J. J. [4 ]
机构
[1] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli, Taiwan
[2] Lunghwa Univ Sci & Technol, Taoyuan, Taiwan
[3] I Lan Hosp, ILan, Taiwan
[4] I shou Univ, Kaohsiung, Taiwan
来源
COMPUTERS IN CARDIOLOGY 2007, VOL 34 | 2007年 / 34卷
关键词
D O I
10.1109/CIC.2007.4745427
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The function of left atrium can be accurately estimated non-invasively using 4D CT cardiac images. A self-developed image analysis program will first reconstruct 3D volume of heart. Then, one may re-sample images for veins from the accurately deleting the 4 pulmonary atrium and set the boundary. With the prior processed information, the active contour methodology and seed regional growth methodology were implemented to delineate the atrial contour. With a calibration standard of 500 ml saline with contrast medium in bag, both methods were able to estimate volume within 5% of error. Thirty sets of patient's CT cardiac images that were acquired at 30% and 90% of RR interval. The dimension of pulmonary veins and the left atrial volume was evaluated. The contractility of pulmonary vein and the Ejection Fraction (EF) of atrium was calculated. The result shows that the left atrium with a larger volume will have a poor ejection fraction.
引用
收藏
页码:85 / +
页数:2
相关论文
共 8 条
[1]   Subclinical pulmonary vein narrowing after ablation for atrial fibrillation [J].
Hauser, TH ;
Yeon, SB ;
McClennen, S ;
Katsimaglis, G ;
Kissinger, KV ;
Josephson, ME ;
Rofsky, NM ;
Manning, WJ .
HEART, 2005, 91 (05) :672-673
[2]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331
[3]   Pulmonary vein diameter, cross-sectional area, and shape: CT analysis [J].
Kim, YH ;
Marom, EM ;
Herndon, JE ;
McAdams, HP .
RADIOLOGY, 2005, 235 (01) :43-49
[4]  
Pappone C, 2000, CIRCULATION, V102, P2619
[5]   Pulmonary vein dilation in patients with atrial fibrillation: Detection by magnetic resonance imaging [J].
Tsao, HM ;
Yu, WC ;
Cheng, HC ;
Wu, MH ;
Tai, CT ;
Lin, WS ;
Ding, YA ;
Chang, MS ;
Chen, SA .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (07) :809-813
[6]   Role of right middle pulmonary vein in patients with paroxysmal atrial fibrillation [J].
Tsao, HM ;
Wu, MH ;
Yu, WC ;
Tai, CT ;
Lin, YK ;
Hsieh, MH ;
Ding, YA ;
Chang, MS ;
Chen, SA .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (12) :1353-1357
[7]   Extensive ablation during pulmonary vein antrum isolation has no adverse impact on left atrial function: An echocardiography and cine computed tomography analysis [J].
Verma, Atul ;
Kilicaslan, Fethi ;
Adams, James R. ;
Hao, Steven ;
Beheiry, Salwa ;
Minor, Stephen ;
Ozduran, Volkan ;
Elayi, Samy Claude ;
Martin, David O. ;
Schweikert, Robert A. ;
Saliba, Walid ;
Thomas, James D. ;
Garcia, Mario ;
Klein, Allan ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (07) :741-746
[8]   ROPES: A semiautomated segmentation method for accelerated analysis of three-dimensional echocardiographic data [J].
Wolf, I ;
Hastenteufel, M ;
De Simone, R ;
Vetter, M ;
Glombitza, G ;
Mottl-Link, S ;
Vahl, CF ;
Meinzer, HP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1091-1104