Better Inflation Time of Stent Balloon for Second-Generation Drug-Eluting Stent Expansion and Apposition: An Optical Coherence Tomography Study

被引:9
作者
Ann, Soe Hee [1 ]
Chung, Jae-Wook [2 ]
Jin, Cai De [1 ]
Lee, Jun Ho [1 ]
Kim, Jong Min [1 ]
Garg, Scot [3 ]
Shin, Eun-seok [1 ]
机构
[1] Univ Ulsan, Coll Med, Ulsan Univ Hosp, Ulsan 680749, South Korea
[2] Yeungnam Univ, Coll Med, Taegu, South Korea
[3] East Lancashire Hosp NHS Trust, Blackburn, Lancs, England
关键词
BARE-METAL STENTS; INTRAVASCULAR ULTRASOUND; POST-DILATATION; THROMBOSIS; IMPACT; IMPLANTATION; DEPLOYMENT; PRESSURE; OUTCOMES;
D O I
10.1111/joic.12096
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We tried to determine the effect of stent balloon inflation time on stent expansion and apposition using optical coherence tomography. Background Second-generation drug-eluting stents (DES) have thin struts; however, inflation times for optimal stent expansion and apposition are unknown in vivo. Methods Subjects included 17 patients (18 de novo coronary artery lesions), in whom Resolute Integrity -> (n = 9) and Xience Prime -> (n = 9) DES were deployed. All stents were inflated 3 times to the nominal inflation pressure (8.9 +/- 0.6 atm) using the stent delivery balloon. The first inflation continued until the stent was angiographically fully expanded; the other 2 lasted 15 and 30 seconds, respectively. Results After the first, second, and third inflation of stent balloon, stent area (5.94 +/- 1.7, 6.69 +/- 1.8, 7.05 +/- 1.8 mm(2), P < 0.001) and stent volume (146.94 +/- 59.40, 166.78 +/- 69.55, 177.25 +/- 69.19 mm(3), P < 0.001) increased significantly. The number of malapposed struts (18.0 +/- 17.0, 7.9 +/- 10.2, 7.4 +/- 10.8, P < 0.001) and the mean depth of malapposed struts (188.9 +/- 75.6, 120.3 +/- 101.4, 95.4 +/- 86.8 mu m, P < 0.001) decreased. Malapposed stent area (0.62 +/- 0.32, 0.52 +/- 0.21 mm(2), P < 0.05) and the malapposed stent volume (15.03 +/- 7.78, 12.64 +/- 5.16 mm(3), P < 0.05) decreased significantly following the second inflation; the third inflation gave no additional benefits to these parameters. There was no adverse clinical outcome after each stent balloon inflation. Conclusions Additional 15 seconds of inflation after the angiographically full expansion of the stent balloon allows better stent expansion and apposition even though the inflation pressure is nominal pressure. (J Interven Cardiol 2014;27:171-176)
引用
收藏
页码:171 / 176
页数:6
相关论文
共 21 条
[1]   Findings of intravascular ultrasound during acute stent thrombosis [J].
Alfonso, F ;
Suárez, A ;
Angiolillo, DJ ;
Sabaté, M ;
Escaned, J ;
Moreno, R ;
Hernández, R ;
Bañuelos, C ;
Macaya, C .
HEART, 2004, 90 (12) :1455-1459
[2]   Effect of balloon inflation time on expansion of sirolimus-eluting stent [J].
Asano, Tatsuhiko ;
Kobayashi, Yoshio ;
Fukushima, Kenichi ;
Iwata, Yo ;
Kitahara, Hideki ;
Ishio, Naoki ;
Nakayama, Takashi ;
Kuroda, Nakabumi ;
Komuro, Issei .
HEART AND VESSELS, 2009, 24 (05) :335-339
[3]   Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse in-stent coronary restenosis [J].
Blackman, DJ ;
Porto, I ;
Shirodaria, C ;
Channon, KM ;
Banning, AP .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (07) :922-925
[4]   Underexpansion of sirollimus-elluting stents: Incidence and relationship to delivery pressure [J].
Cheneau, E ;
Satler, LF ;
Escolar, E ;
Suddath, WI ;
Kent, KM ;
Weissman, NJ ;
Waksman, R ;
Pichard, AD .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 65 (02) :222-226
[5]   Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach [J].
Gonzalo, N. ;
Serruys, P. W. ;
Okamura, T. ;
Shen, Z. J. ;
Onuma, Y. ;
Garcia-Garcia, H. M. ;
Sarno, G. ;
Schultz, C. ;
van Geuns, R. J. ;
Ligthart, J. ;
Regar, E. .
HEART, 2009, 95 (23) :1913-1919
[6]   Examination of the In Vivo Mechanisms of Late Drug-Eluting Stent Thrombosis Findings From Optical Coherence Tomography and Intravascular Ultrasound Imaging [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Musumeci, Giuseppe ;
Gerber, Robert ;
Biondi-Zoccai, Giuseppe ;
Ikejima, Hideyuki ;
Ladich, Elena ;
Lortkipanidze, Nikoloz ;
Matiashvili, Aleksandre ;
Valsecchi, Orazio ;
Virmani, Renu ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :12-20
[7]   Duration of balloon inflation for optimal stent deployment: Five Seconds Is Not Enough [J].
Hovasse, Thomas ;
Mylotte, Darren ;
Garot, Philippe ;
Salvatella, Neus ;
Morice, Marie-Claude ;
Chevalier, Bernard ;
Pichard, Augusto ;
Lefevre, Thierry .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) :446-453
[8]   Better stent expansion by two-time inflation of stent balloon and its responsible mechanism [J].
Iwamoto, Yumiko ;
Okamoto, Mitsunori ;
Hashimoto, Masaki ;
Fukuda, Yukihiro ;
Iwamoto, Akimichi ;
Iwasaki, Toshitaka ;
Kinoshita, Hiroki ;
Kihara, Yasuki .
JOURNAL OF CARDIOLOGY, 2012, 59 (02) :160-166
[9]   Comparison of paclitaxel-eluting stent and sirolimus-eluting stent expansion at incremental delivery pressures [J].
Javaid, Aamir ;
Chu, William W. ;
Cheneau, Edouard ;
Clavijo, Leonardo C. ;
Satler, Lowell F. ;
Kent, Kenneth M. ;
Weissman, Neil J. ;
Pichard, Augusto D. ;
Waksman, Ron .
CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2006, 7 (04) :208-211
[10]   Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents [J].
Kastrati, Adnan ;
Mehilli, Julinda ;
Pache, Juergen ;
Kaiser, Christoph ;
Valgimigli, Marco ;
Kelbaek, Henning ;
Menichelli, Maurizio ;
Sabate, Manel ;
Suttorp, Maarten J. ;
Baumgart, Dietrich ;
Seyfarth, Melchior ;
Pfisterer, Matthias E. ;
Schoemig, Albert .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :1030-1039