Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry

被引:91
作者
Cortada, Carol [3 ]
Vidal, Lorena [1 ,2 ]
Pastor, Raul [3 ]
Santiago, Noemi [3 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Labaqua SA, Alicante 03114, Spain
关键词
Organochlorine pesticides; Dispersive liquid-liquid microextraction; Sample preparation; Water samples analysis; ELECTRON-CAPTURE DETECTION; SINGLE-DROP MICROEXTRACTION; HOLLOW-FIBER MEMBRANE; PHASE MICROEXTRACTION; ORGANOPHOSPHORUS PESTICIDES; SENSITIVE METHOD; MATRICES;
D O I
10.1016/j.aca.2009.07.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple dispersive liquid-liquid microextraction (DLLME) has been developed to pre-concentrate eighteen organochlorine pesticides (OCPs) from water samples prior to analysis by gas chromatography-mass spectrometry (GC-MS). The studied variables were extraction solvent type and volume, disperser solvent type and volume. aqueous sample volume and temperature. The optimum experimental conditions of the proposed DLLME method were: a mixture of 10 mu L tetrachloroethylene (extraction solvent)and 1 mL acetone (disperser solvent) exposed for 30s to 10 mL of the aqueous sample at room temperature (20 degrees C). Centrifugation of cloudy solution was carried out at 2300 rpm for 3 min to allow phases separation. Finally, 2 mu L of extractant was recovered and injected into the GC-MS instrument. Under the optimum conditions, the enrichment factors ranged between 46 and 316. The calculated calibration curves gave a high-level linearity for all target analytes with correlation coefficients ranging between 0.9967 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5% and 15% (n = 8), and the detection limits were in the range of 1-25 ng L-1. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA methods 525.2 and 625. Analysis of spiked real water samples revealed that the matrix had no effect on extraction for river, surface and tap waters; however, urban wastewater sample shown a little effect for five out of eighteen analytes. V 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 29 条
[1]   Determination of 21 organochlorine pesticides in tree leaves using solid-phase extraction clean-up cartridges [J].
Barriada-Pereira, M ;
González-Castro, MJ ;
Muniategui-Lorenzo, S ;
López-Mahía, P ;
Prada-Rodríguez, D ;
Fernández-Fernández, E .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :133-139
[2]   Determination of organochlorine pesticides in seawater using liquid-phase hollow fibre membrane microextraction and gas chromatography-mass spectrometry [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) :191-199
[3]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]   Troubleshooting in the trace analysis of organochlorine pesticides in water samples [J].
Concha-Graña, E ;
Turnes-Carou, MI ;
Muniategui-Lorenzo, S ;
López-Mahia, P ;
Fernández-Fernández, E ;
Prada-Rodríguez, D .
CHROMATOGRAPHIA, 2001, 54 (7-8) :501-506
[5]   Determination of organochlorine pesticides in complex matrices by single-drop microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Tejada, Sergio ;
Romo, Alicia ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 638 (01) :29-35
[6]   Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC) [J].
de Jager, LS ;
Andrews, ARJ .
ANALYST, 2000, 125 (11) :1943-1948
[7]   Development of dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a simple, rapid and highly sensitive method for the determination of phthalate esters in water samples [J].
Farahani, Hadi ;
Norouzi, Parviz ;
Dinarvand, Rassoul ;
Ganjali, Mohammad Reza .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) :105-112
[8]   Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection [J].
Farina, Laura ;
Boido, Eduardo ;
Carrau, Francisco ;
Dellacassa, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :46-50
[9]   Methods for selective determination of persistent organochlorine pesticide residues in water and sediments by capillary gas chromatography and electron-capture detection [J].
Fatoki, OS ;
Awofolu, RO .
JOURNAL OF CHROMATOGRAPHY A, 2003, 983 (1-2) :225-236
[10]   Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection [J].
Fattahi, Nazir ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jahromi, Elham. Zeini .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :23-29