Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field

被引:7
|
作者
Castets, Charles R. [1 ,2 ]
Lefrancois, William [1 ,2 ]
Wecker, Didier [3 ]
Ribot, Emeline J. [1 ,2 ]
Trotier, Aurelien J. [1 ,2 ]
Thiaudiere, Eric [1 ,2 ]
Franconi, Jean-Michel [1 ,2 ]
Miraux, Sylvain [1 ,2 ]
机构
[1] CNRS, UMR5536, Ctr Resonance Magnet Syst Biol, 146 Rue Leo Saignat, F-33076 Bordeaux, France
[2] Univ Bordeaux, Ctr Resonance Magnet Syst Biol, UMR5536, Bordeaux, France
[3] Bruker Biospin MRI GMBH, Ettlingen, Germany
关键词
spiral; 3D; UTE; golden angle; 7T; self-gating; mouse; MR-ANGIOGRAPHY; CINE MRI; RESONANCE; ACQUISITION; RESOLUTION; RECONSTRUCTION; TRAJECTORIES; COMBINATION; SEQUENCES; CARTILAGE;
D O I
10.1002/mrm.26263
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. MethodsA disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding was performed by tilting the disks with a golden angle. The sharpness was first calculated at different T2* values. Then, the sharpness was measured on phantom using variable undersampling ratios. Finally, the sampling method was validated by whole brain time-of-flight angiography and ultrasmall superparamagnetic iron oxide (USPIO) enhanced free-breathing liver angiography on mouse. ResultsThe in vitro results demonstrated the robustness of the method for short T2* and high undersampling ratios. In vivo experiments showed the ability to properly detect small vessels in the brain with an acquisition time shorter than 1min. Free-breathing mice liver angiography showed the insensitivity of this protocol toward motions and flow artifacts, and enabled the visualization of liver motion during breathing. ConclusionsThe method implemented here allowed fast 3D k-space sampling with a high undersampling ratio. Combining the advantages of center-out spirals with the flexibility of the golden angle approach could have major implications for real-time imaging. Magn Reson Med 77:1831-1840, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1831 / 1840
页数:10
相关论文
共 30 条
  • [1] Feasibility of chest spiral 3D ultrashort echo time magnetic resonance imaging for intrathoracic metastasis work-up in breast cancer
    Nam, Kyung Jin
    Kang, Taewoo
    Lee, Ji Won
    Hwang, Minhee
    Kim, Jin You
    Yeom, Jeong A.
    Jeong, Yeon Joo
    JOURNAL OF THORACIC DISEASE, 2023, 15 (10) : 5485 - 5493
  • [2] Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Fan, Shu-Juan
    Wong, Jonathan
    Xue, Yanping
    Cai, Zhenyu
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [3] Depiction of Achilles Tendon Microstructure In Vivo Using High-Resolution 3-Dimensional Ultrashort Echo-Time Magnetic Resonance Imaging at 7 T
    Han, Misung
    Larson, Peder E. Z.
    Liu, Jing
    Krug, Roland
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 339 - 345
  • [4] Comparison of diagnostic quality of 3D ultrashort-echo-time techniques for pulmonary magnetic resonance imaging in free-breathing
    Metz, Corona
    Weng, Andreas Max
    Boeckle, David
    Heidenreich, Julius Frederik
    Slawig, Anne
    Benkert, Thomas
    Kraus, Sabrina
    Koestler, Herbert
    Veldhoen, Simon
    ACTA RADIOLOGICA, 2023, 64 (05) : 1851 - 1858
  • [5] Quantitative 3D Ultrashort Echo Time Magnetization Transfer Imaging for Evaluation of Knee Cartilage Degeneration In Vivo
    Xue, Yan-Ping
    Ma, Ya-Jun
    Wu, Mei
    Jerban, Saeed
    Wei, Zhao
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) : 1294 - 1302
  • [6] 3D printed phantoms mimicking cortical bone for the assessment of ultrashort echo time magnetic resonance imaging
    Rai, Robba
    Manton, David
    Jameson, Michael G.
    Josan, Sonal
    Barton, Michael B.
    Holloway, Lois C.
    Liney, Gary P.
    MEDICAL PHYSICS, 2018, 45 (02) : 758 - 766
  • [7] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [8] Oxygen-enhanced 3D radial ultrashort echo time magnetic resonance imaging in the healthy human lung
    Kruger, Stanley J.
    Fain, Sean B.
    Johnson, Kevin M.
    Cadman, Robert V.
    Nagle, Scott K.
    NMR IN BIOMEDICINE, 2014, 27 (12) : 1535 - 1541
  • [9] Rapid dynamic contrast-enhanced MRI for small animals at 7T using 3D ultra-short echo time and golden-angle radial sparse parallel MRI
    Zhang, Jin
    Feng, Li
    Otazo, Ricardo
    Kim, Sungheon Gene
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 140 - 152
  • [10] Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Wong, Jonathan
    Chang, Eric Y.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    RADIOLOGY, 2020, 294 (02) : 362 - 374