Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin

被引:17
|
作者
L'homme, R
Brouwers, E
Al-Maharik, N
Lapcík, O
Hampl, R
Mikola, H
Wähälä, K
Adlercreutz, H
机构
[1] Univ Helsinki, Folkhalsan Res Ctr, Div Clin Chem, FIN-00014 Helsinki, Finland
[2] Univ Helsinki, Folkhalsan Res Ctr, Inst Prevent Med, FIN-00014 Helsinki, Finland
[3] Univ Helsinki, Dept Chem, Organ Chem Lab, FIN-00014 Helsinki, Finland
[4] Inst Chem, Dept Chem Nat Subst, Prague 16628 6, Czech Republic
[5] Inst Endocrinol, Prague 11694 1, Czech Republic
[6] Wallac Oy, FIN-20101 Turku, Finland
关键词
immunoassay; phytoestrogens; isofavones; urine; O-desmethylangolensin; fluorometry;
D O I
10.1016/S0960-0760(02)00073-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We present a method for the determination of the phytoestrogen metabolite O-desmethylangolensin (O-DMA) in plasma (serum) and in urine. O-DMA is a metabolite of daidzein, which occurs in soybeans. It has been suggested that isoflavones may afford protection against breast and prostate cancer and therefore, also the metabolites are of interest. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After the synthesis of 4"-O-carboxymethyl-O-DMA, this compound is coupled to bovine serum albumin, and then used as antigen in immunization of rabbits. The tracers with the europium chelate are synthesized using the same 4"-O-derivative of the alpha-methyldeoxybenzoin. After enzymatic hydrolysis and ether extraction the immunoassay is carried out by time resolved fluoroimmunoassay (TR-FIA). Cross-reactivity was tested with angolensin, dihydrogenistein, dihydrodaidzein, equol, 6'-OH-angolensin, trans-4-OH-equol, 6'-OH-O-DMA, cis-4-OH-equol and 5-OH-equol. The antiserum cross-reacted only with angolensin. This cross-reactivity seems not to influence the results, which were highly specific. Plasma samples are hydrolyzed and extracted. Urine samples are analyzed directly after hydrolysis without extraction. The correlation coefficient between the plasma TR-FIA results and the GC-MS results was high; r value was 0.985. The correlation coefficient between the urine TR-FIA results and the GC-MS results was high over the entire range of concentrations (0-1500 nmol/l); r value was 0.976, but lower in the low concentration range (0-100 nmol/l), i.e. value was 0.631. The intra-assay coefficients of variation (CVs) for plasma O-DMA concentrations and for urine O-DMA concentrations at three different concentrations varied 2.8-7.7 and 3.0-6.0%, respectively and the inter-assay CVs varied 3.8-8.9 and 4.4-6.6%, respectively. The working range of the plasma and urine O-DMA assays was 0.5-512 nmol/l. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [31] A homogeneous time-resolved fluoroimmunoassay (TR-FIA) using antibody mediated luminescence quenching
    Sellrie, Frank
    Beck, Michael
    Hildebrandt, Niko
    Micheel, Burkhard
    ANALYTICAL METHODS, 2010, 2 (09) : 1298 - 1301
  • [32] determination of Anticyclic Citrullinated Peptide Based on Biotin-Streptavidin-Amplified Time-Resolved Fluoroimmunoassay
    Sheng, Huiming
    Hu, Zhi-Gang
    Liu, Jie
    Yuan, Fenghong
    Li, Mei
    Zou, Yaohong
    Chen, Yu
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2015, 29 (06) : 474 - 479
  • [33] A direct competitive inhibition time-resolved fluoroimmunoassay for the detection of unconjugated estriol in serum of pregnant women
    Tang, Yong-ping
    Zhao, Su-qing
    Wu, Ying-song
    Zhou, Jian-wei
    Li, Ming
    ANALYTICAL METHODS, 2013, 5 (16) : 4068 - 4073
  • [34] A prototype of ultrasensitive time-resolved fluoroimmunoassay for the quantitation of lead in plasma using a fluorescence-enhanced europium chelate label for the detection system
    Darwish, Ibrahim A.
    Suzuki, Kenzi
    Ogawa, Hiroshi
    Wang, Zongzhi
    RSC ADVANCES, 2024, 14 (13) : 8671 - 8683
  • [35] O-desmethylangolensin inhibits the proliferation of human breast cancer MCF-7 cells by inducing apoptosis and promoting cell cycle arrest
    Choi, Eun Jeong
    Kim, Gun-Hee
    ONCOLOGY LETTERS, 2013, 6 (06) : 1784 - 1788
  • [36] A combination of soy isoflavones and cello-oligosaccharides changes equol/O-desmethylangolensin production ratio and attenuates bone fragility in ovariectomized mice
    Fujii, Shungo
    Takahashi, Nobuyuki
    Inoue, Hirofumi
    Katsumata, Shin-ichi
    Kikkawa, Yuji
    Machida, Makoto
    Ishimi, Yoshiko
    Uehara, Mariko
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2016, 80 (08) : 1632 - 1635
  • [37] A competitive dual-label time-resolved fluoroimmunoassay for the simultaneous determination of chloramphenicol and ractopamine in swine tissue
    Zhang Zhen
    Liu JingFu
    Yao Yan
    Jiang GuiBin
    CHINESE SCIENCE BULLETIN, 2011, 56 (15): : 1543 - 1547
  • [38] A Magnetic Nanoparticle-Based Time-Resolved Fluoroimmunoassay for Determination of the Cytokeratin 19 Fragment in Human Serum
    Lin, Guanfeng
    Liu, Tiancai
    Hou, Jingyuan
    Ren, Zhiqi
    Zhou, Jianwei
    Liang, Qianni
    Chen, Zhenhua
    Dong, Wenqi
    Wu, Yingsong
    JOURNAL OF FLUORESCENCE, 2015, 25 (02) : 361 - 367
  • [39] Enhanced biosynthesis of O-desmethylangolensin from daidzein by a novel oxygen-tolerant cock intestinal bacterium in the presence of atmospheric oxygen
    Li, M.
    Li, H.
    Zhang, C.
    Wang, X-L.
    Chen, B-H.
    Hao, Q-H.
    Wang, S-Y.
    JOURNAL OF APPLIED MICROBIOLOGY, 2015, 118 (03) : 619 - 628
  • [40] Dual-label time-resolved fluoroimmunoassay for simultaneous detection of aflatoxin B1 and ochratoxin A
    Huang, Biao
    Xiao, Hualong
    Zhang, Jue
    Zhang, Lianfen
    Yang, Hailin
    Zhang, Yi
    Jin, Jian
    ARCHIVES OF TOXICOLOGY, 2009, 83 (06) : 619 - 624