Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients

被引:6
|
作者
Xu, Guohui [1 ]
Wu, Xuehai [2 ]
Yu, Jian [2 ]
Ding, Hong [1 ]
Ni, Zilong [3 ]
Wang, Yong [1 ]
机构
[1] Fudan Univ, Dept Ultrason Med, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Dept Neurosugery, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[3] Simens Healthineers, Dept Ultrasound Clin Market, 399 West Haiyang Rd, Shanghai 200126, Peoples R China
关键词
Intracranial pressure; Optic nerve; Optic nerve sheath; Optic nerve sheath diameter; Shear-wave elastography; Ultrasound; OPTIC-NERVE SHEATH; TRAUMATIC BRAIN-INJURY; DIAMETER; ULTRASOUND; PRINCIPLES; ACCURACY; STRAIN;
D O I
10.1016/j.jocn.2022.03.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine if Young's modulus of the optic nerve (ON) structure as measured by shear-wave elastography can suggest changes in intracranial pressure (ICP) in neuro-critical care patients. Materials and methods: Thirty-one healthy volunteers and twenty-two neuro-critical care patients were enrolled. ON sheath (ONS) diameter (ONSD) values and Young's modulus measurements of volunteers were collected in a calm state and during a Valsalva maneuver (VM). Ultrasound measurements and ICP values of patients were collected on operation day and at 24 and 48 h after the operation; measurements were thereafter assigned to three groups: severely elevated (ICP greater than 22 mmHg), mildly elevated (ICP = 14-22 mmHg), and normal (ICP <= 13 mmHg). Results: ONSD and Young's modulus for the ON and ONS of volunteers during VM were higher than those in the calm state (all P < 0.001). In contrast to ONSD, Young's modulus for ON and ONS did not correlate with age, body mass index, or sex. The best cutoff values of Young's modulus for ON for predicting elevated and severely elevated ICP were 16.67 kPa and 22.74 kPa, respectively. Accordingly, the sensitivity values were 96.7% and 88.9%, and the specificity values were 86.1% and 73.7%, which had the same diagnostic performance as ONSD. Conclusion: Young's modulus of the ON accurately reflects changes in ICP. It is not confounded by age, sex, or body mass index compared to ONSD.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [41] Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto’s thyroiditis patients
    Turgay Kara
    Fatih Ateş
    Mehmet Sedat Durmaz
    Nesibe Akyürek
    Funda Gökgöz Durmaz
    Bora Özbakır
    Mehmet Öztürk
    Journal of Ultrasound, 2020, 23 : 543 - 551
  • [42] Predicting hepatocellular carcinoma: A new non-invasive model based on shear wave elastography
    Jiang, Dong
    Qian, Yi
    Gu, Yi-Jun
    Wang, Ru
    Yu, Hua
    Dong, Hui
    Chen, Dong-Yu
    Chen, Yan
    Jiang, Hao-Zheng
    Tan, Bi-Bo
    Peng, Min
    Li, Yi-Ran
    WORLD JOURNAL OF GASTROENTEROLOGY, 2024, 30 (25) : 3166 - 3178
  • [43] Effects of pneumoperitoneum and Trendelenburg position on intracranial pressure assessed using different non-invasive methods
    Robba, C.
    Cardim, D.
    Donnelly, J.
    Bertuccio, A.
    Bacigaluppi, S.
    Bragazzi, N.
    Cabella, B.
    Liu, X.
    Matta, B.
    Lattuada, M.
    Czosnyka, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (06) : 783 - 791
  • [44] Assessment of the optic nerve, optic disc, and perineural area using shear-wave elastography in patients with multiple sclerosis
    Sahin Ediz, Suna
    Atalay, Basak
    Aydin Canturk, Ilknur
    Kabaalioglu, Adnan
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2021, 75 (11)
  • [45] Non-invasive Monitoring of Intracranial Pressure Using Transcranial Doppler Ultrasonography: Is It Possible?
    Cardim, Danilo
    Robba, C.
    Bohdanowicz, M.
    Donnelly, J.
    Cabella, B.
    Liu, X.
    Cabeleira, M.
    Smielewski, P.
    Schmidt, B.
    Czosnyka, M.
    NEUROCRITICAL CARE, 2016, 25 (03) : 473 - 491
  • [46] Influence of the physical pressure of an ultrasound probe on shear-wave elastography measurements of the gastrocnemius muscle in a paediatric population: a non-interventional cohort study
    Cebula, Agnieszka
    Cebula, Maciej
    Czajkowska, Marta
    Gruszczynska, Katarzyna
    Kopyta, Ilona
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : E24 - E29
  • [47] Non-Invasive Assessment of Local Pulse Wave Velocity as Function of Arterial Pressure
    Nabeel, P. M.
    Kiran, Raj, V
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 672 - 677
  • [48] A non-invasive technique for estimating carpal tunnel pressure by measuring shear wave speed in tendon: A feasibility study
    Wang, Yuexiang
    Qiang, Bo
    Zhang, Xiaoming
    Greenleaf, James F.
    An, Kai-Nan
    Amadio, Peter C.
    Zhao, Chunfeng
    JOURNAL OF BIOMECHANICS, 2012, 45 (16) : 2927 - 2930
  • [49] A new novel method for assessing intracranial pressure using non-invasive fundus images: a pilot study
    Andersen, Mikkel Schou
    Pedersen, Christian Bonde
    Poulsen, Frantz Rom
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [50] The Current State of Non-Invasive Measurement of Intracranial Pressure in Patients with Craniosynostosis: A Systematic Review
    Patel, Viren
    Lu, Quan
    Fodor, Ray
    Patel, Niyant
    FACE, 2024, 5 (03): : 451 - 462