Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients

被引:6
|
作者
Xu, Guohui [1 ]
Wu, Xuehai [2 ]
Yu, Jian [2 ]
Ding, Hong [1 ]
Ni, Zilong [3 ]
Wang, Yong [1 ]
机构
[1] Fudan Univ, Dept Ultrason Med, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Dept Neurosugery, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[3] Simens Healthineers, Dept Ultrasound Clin Market, 399 West Haiyang Rd, Shanghai 200126, Peoples R China
关键词
Intracranial pressure; Optic nerve; Optic nerve sheath; Optic nerve sheath diameter; Shear-wave elastography; Ultrasound; OPTIC-NERVE SHEATH; TRAUMATIC BRAIN-INJURY; DIAMETER; ULTRASOUND; PRINCIPLES; ACCURACY; STRAIN;
D O I
10.1016/j.jocn.2022.03.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine if Young's modulus of the optic nerve (ON) structure as measured by shear-wave elastography can suggest changes in intracranial pressure (ICP) in neuro-critical care patients. Materials and methods: Thirty-one healthy volunteers and twenty-two neuro-critical care patients were enrolled. ON sheath (ONS) diameter (ONSD) values and Young's modulus measurements of volunteers were collected in a calm state and during a Valsalva maneuver (VM). Ultrasound measurements and ICP values of patients were collected on operation day and at 24 and 48 h after the operation; measurements were thereafter assigned to three groups: severely elevated (ICP greater than 22 mmHg), mildly elevated (ICP = 14-22 mmHg), and normal (ICP <= 13 mmHg). Results: ONSD and Young's modulus for the ON and ONS of volunteers during VM were higher than those in the calm state (all P < 0.001). In contrast to ONSD, Young's modulus for ON and ONS did not correlate with age, body mass index, or sex. The best cutoff values of Young's modulus for ON for predicting elevated and severely elevated ICP were 16.67 kPa and 22.74 kPa, respectively. Accordingly, the sensitivity values were 96.7% and 88.9%, and the specificity values were 86.1% and 73.7%, which had the same diagnostic performance as ONSD. Conclusion: Young's modulus of the ON accurately reflects changes in ICP. It is not confounded by age, sex, or body mass index compared to ONSD.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [11] Assessment of the optic nerve using strain and shear-wave elastography in patients with pseudotumour cerebri
    Asal, N.
    Inal, M.
    Sahan, M. H.
    Say, B.
    CLINICAL RADIOLOGY, 2020, 75 (08) : 629 - 635
  • [12] Fetal optic nerve sheath measurement as a non-invasive tool for assessment of increased intracranial pressure
    Haratz, K.
    Vinals, F.
    Lev, D.
    Feit, H.
    Ben-Sira, L.
    Lerman-Sagie, T.
    Malinger, G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 38 (06) : 646 - 651
  • [13] Non-invasive assessment of kidney allograft fibrosis with shear wave elastography: A radiological-pathological correlation analysis
    Ma, Maggie K. M.
    Law, Helen K. W.
    Tse, Kin Sun
    Chan, Kwok Wah
    Chan, Gary C. W.
    Yap, Desmond Y. H.
    Mok, Maggie M. Y.
    Kwan, Lorraine P. Y.
    Tang, Sydney C. W.
    Choy, Bo Ying
    Chan, Tak Mao
    INTERNATIONAL JOURNAL OF UROLOGY, 2018, 25 (05) : 450 - 455
  • [14] NON-INVASIVE ASSESSMENT OF CHANGES IN MUSCLE INJURY BY ULTRASOUND SHEAR WAVE ELASTOGRAPHY: AN EXPERIMENTAL STUDY IN CONTUSION MODEL
    Zhou, Xiaohua
    Wang, Chuang
    Qiu, Shaodong
    Mao, Lin
    Chen, Fei
    Chen, Shaona
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (12) : 2759 - 2767
  • [15] Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto's thyroiditis patients
    Kara, Turgay
    Ates, Fatih
    Durmaz, Mehmet Sedat
    Akyurek, Nesibe
    Durmaz, Funda Gokgoz
    Ozbakir, Bora
    Ozturk, Mehmet
    JOURNAL OF ULTRASOUND, 2020, 23 (04) : 543 - 551
  • [16] QUANTITATIVE ASSESSMENT OF SKIN STIFFNESS IN LOCALIZED SCLERODERMA USING ULTRASOUND SHEAR-WAVE ELASTOGRAPHY
    Wang, Liyun
    Yan, Feng
    Yang, Yujia
    Xiang, Xi
    Qiu, Li
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (07) : 1339 - 1347
  • [17] Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study
    Robba, Chiara
    Cardim, Danilo
    Tajsic, Tamara
    Pietersen, Justine
    Bulman, Michael
    Donnelly, Joseph
    Lavinio, Andrea
    Gupta, Arun
    Menon, David K.
    Hutchinson, Peter J. A.
    Czosnyka, Marek
    PLOS MEDICINE, 2017, 14 (07)
  • [18] Intraoperative Quantitative Measurement of Brain Tumor Stiffness and Intracranial Pressure Assessment using Ultrasound Shear Wave Elastography
    Imbault, M.
    Demene, C.
    Mossad, M.
    Gennisson, J. L.
    Tanter, M.
    Chauvet, D.
    Capelle, L.
    Karachi, C.
    Boch, A. L.
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 201 - 204
  • [19] NON-INVASIVE QUANTITATIVE ASSESSMENT OF MUSCLE FORCE BASED ON ULTRASONIC SHEAR WAVE ELASTOGRAPHY
    Liu, Jing
    Qian, Zhihui
    Wang, Kunyang
    Wu, Jianan
    Jabran, Ali
    Ren, Luquan
    Ren, Lei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02) : 440 - 451
  • [20] Non-invasive assessment of intracranial pressure through the eyes: current developments, limitations, and future directions
    Viarsagh, Solmaz Bastani
    Agar, Ashish
    Lawlor, Mitchell
    Fraser, Clare
    Golzan, Mojtaba
    FRONTIERS IN NEUROLOGY, 2024, 15