Non-invasive intracranial pressure assessment using shear-wave elastography in neuro-critical care patients

被引:6
|
作者
Xu, Guohui [1 ]
Wu, Xuehai [2 ]
Yu, Jian [2 ]
Ding, Hong [1 ]
Ni, Zilong [3 ]
Wang, Yong [1 ]
机构
[1] Fudan Univ, Dept Ultrason Med, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[2] Fudan Univ, Dept Neurosugery, Affiliated Huashan Hosp, 12 Middle Wulumuqi Rd, Shanghai 200040, Peoples R China
[3] Simens Healthineers, Dept Ultrasound Clin Market, 399 West Haiyang Rd, Shanghai 200126, Peoples R China
关键词
Intracranial pressure; Optic nerve; Optic nerve sheath; Optic nerve sheath diameter; Shear-wave elastography; Ultrasound; OPTIC-NERVE SHEATH; TRAUMATIC BRAIN-INJURY; DIAMETER; ULTRASOUND; PRINCIPLES; ACCURACY; STRAIN;
D O I
10.1016/j.jocn.2022.03.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine if Young's modulus of the optic nerve (ON) structure as measured by shear-wave elastography can suggest changes in intracranial pressure (ICP) in neuro-critical care patients. Materials and methods: Thirty-one healthy volunteers and twenty-two neuro-critical care patients were enrolled. ON sheath (ONS) diameter (ONSD) values and Young's modulus measurements of volunteers were collected in a calm state and during a Valsalva maneuver (VM). Ultrasound measurements and ICP values of patients were collected on operation day and at 24 and 48 h after the operation; measurements were thereafter assigned to three groups: severely elevated (ICP greater than 22 mmHg), mildly elevated (ICP = 14-22 mmHg), and normal (ICP <= 13 mmHg). Results: ONSD and Young's modulus for the ON and ONS of volunteers during VM were higher than those in the calm state (all P < 0.001). In contrast to ONSD, Young's modulus for ON and ONS did not correlate with age, body mass index, or sex. The best cutoff values of Young's modulus for ON for predicting elevated and severely elevated ICP were 16.67 kPa and 22.74 kPa, respectively. Accordingly, the sensitivity values were 96.7% and 88.9%, and the specificity values were 86.1% and 73.7%, which had the same diagnostic performance as ONSD. Conclusion: Young's modulus of the ON accurately reflects changes in ICP. It is not confounded by age, sex, or body mass index compared to ONSD.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [1] Non-invasive intracranial pressure assessment
    Padayachy, Llewellyn C.
    CHILDS NERVOUS SYSTEM, 2016, 32 (09) : 1587 - 1597
  • [2] Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients
    Geeraerts, Thomas
    Merceron, Sybille
    Benhamou, Dan
    Vigue, Bernard
    Duranteau, Jacques
    INTENSIVE CARE MEDICINE, 2008, 34 (11) : 2062 - 2067
  • [3] Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients
    Thomas Geeraerts
    Sybille Merceron
    Dan Benhamou
    Bernard Vigué
    Jacques Duranteau
    Intensive Care Medicine, 2008, 34
  • [4] Evaluation of the biomechanical properties of the posterior eye using Shear Wave Elastography in patients with increased intracranial pressure
    Xiao, Chufan
    Huang, Xiaoling
    Li, Maoping
    Wu, Jiarui
    Huang, Huiying
    MEDICAL ULTRASONOGRAPHY, 2021, 23 (03) : 305 - 310
  • [5] Non-invasive assessment of intracranial pressure
    Robba, C.
    Bacigaluppi, S.
    Cardim, D.
    Donnelly, J.
    Bertuccio, A.
    Czosnyka, M.
    ACTA NEUROLOGICA SCANDINAVICA, 2016, 134 (01): : 4 - 21
  • [6] Non-invasive assessment of liver fibrosis using two-dimensional shear wave elastography in patients with autoimmune liver diseases
    Zeng, Jie
    Huang, Ze-Ping
    Zheng, Jian
    Wu, Tao
    Zheng, Rong-Qin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2017, 23 (26) : 4839 - 4846
  • [7] Non-invasive assessment of liver fibrosis using twodimensional shear wave elastography in patients with autoimmune liver diseases
    Jie Zeng
    Ze-Ping Huang
    Jian Zheng
    Tao Wu
    Rong-Qin Zheng
    World Journal of Gastroenterology, 2017, (26) : 4839 - 4846
  • [8] Non-invasive intracranial pressure assessment
    Llewellyn C. Padayachy
    Child's Nervous System, 2016, 32 : 1587 - 1597
  • [9] Non-Invasive Intracranial Pressure Evaluation in an Emergency Room - Point-of-Care Ultrasonography
    Damiani, Daniel
    Damiani, Durval
    BRAZILIAN NEUROSURGERY-ARQUIVOS BRASILEIROS DE NEUROCIRURGIA, 2019, 38 (04): : 279 - 283
  • [10] POINT SHEAR WAVE ELASTOGRAPHY FOR NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN PATIENTS WITH VIRAL HEPATITIS
    Bucsics, Theresa
    Grasl, Benjamin
    Ferlitsch, Arnulf
    Schwabl, Philipp
    Mandorfer, Mattias
    Zinober, Kerstin
    Stern, Rafael
    Chromy, David
    Scheiner, Bernhard
    Sieghart, Wolfgang
    Peck-Radosavljevic, Markus
    Trauner, Michael
    Reiberger, Thomas