Measurement of the index of refraction of an liquid by a cladding depleted fiber Bragg grating

被引:3
|
作者
Shih, Ming Chang [1 ]
Yang, Hui-Hsiung [1 ]
Shih, Chih Hsien [1 ]
机构
[1] Natl Univ Kaohsiung, Dept Elect Engn, Kaohsiung 811, Taiwan
关键词
Fiber Bragg grating sensor; Index of refraction; Liquid identification; TEMPERATURE; SENSOR;
D O I
10.1007/s11082-015-0367-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We demonstrated a method of index of refraction measurement for unknown liquids by using a fiber Bragg grating (FBG) which the cladding layer is depleted to enhance the measurement of Bragg wavelength shift due to the variation of the index of the liquid samples. Process of the etching of the cladding layer of the FBG is described, and the procedure to calibrate the wavelength shift of the FBG in variation of standard index oil is discussed. Measurement of index of a sample liquid as high as 1.45 and within accuracy of 0.01 can be achieved, and a FBG signal interrogation system has been integrated to measure the index of refraction of water with different sugar contents.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Measurement of the index of refraction of an liquid by a cladding depleted fiber Bragg grating
    Ming Chang Shih
    Hui-Hsiung Yang
    Chih Hsien Shih
    Optical and Quantum Electronics, 2016, 48
  • [2] Simultaneous Measurement of Temperature and Refractive Index of Liquid Using Cladding-Etched Double-Core Fiber Bragg Grating
    Kim, Kwang Taek
    Kim, In Soo
    FIBER AND INTEGRATED OPTICS, 2013, 32 (03) : 145 - 152
  • [3] Etched fiber Bragg grating for refractive index distribution measurement
    Luo, Bin-bin
    Zhao, Ming-fu
    Zhou, Xiao-jun
    Shi, Sheng-hui
    Han, Xi
    Wang, Ying
    OPTIK, 2013, 124 (17): : 2777 - 2780
  • [4] Temperature dependency of cladding-etched fiber Bragg grating surrounded with liquid
    Liu, Yinggang
    Zhang, Wei
    Fu, Haiwei
    Jia, Zhenan
    Ma, Chengju
    OPTIK, 2017, 132 : 401 - 406
  • [5] Simultaneous Measurement of Refractive Index and Temperature Using a Hybrid Fiber Bragg Grating/Long-Period Fiber Grating Configuration
    Jesus, C.
    Caldas, P.
    Frazao, O.
    Santos, J. L.
    Jorge, P. A. S.
    Baptista, J. M.
    FIBER AND INTEGRATED OPTICS, 2009, 28 (06) : 440 - 449
  • [6] Side Polished Fiber Bragg Grating Sensor for Simultaneous Measurement of Refractive Index and Temperature
    Chen, Zhe
    Tang, Jieyuan
    Fan, Ruoyan
    Zhong, Yongchun
    Zhang, Jun
    Li, Siben
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [7] Refractive index measurement based on fiber Bragg grating connected with a multimode fiber core
    Shao, Min
    Qiao, Xueguang
    Jiasurname, Zhenan
    Fusurname, Haiwei
    Liu, Yinggang
    Li, Huidong
    Zhao, Xue
    OPTICS COMMUNICATIONS, 2015, 351 : 70 - 74
  • [8] Simultaneous measurement of temperature and refractive index using a fiber Bragg grating and a multimode fiber
    Tong, Zhengrong
    Guo, Yang
    Yang, Xiufeng
    Cao, Ye
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 4053 - 4056
  • [9] Fiber Bragg Grating based bite force measurement
    Umesh, Sharath
    Padma, Srivani
    Asokan, Sundarrajan
    Srinivas, Talabattula
    JOURNAL OF BIOMECHANICS, 2016, 49 (13) : 2877 - 2881
  • [10] Simultaneous measurement of refractive index and temperature based on tapered no-core fiber cascaded with a fiber Bragg grating
    Liu, Yushan
    Xie, Song
    Zheng, Yuanyuan
    Yang, Xiaozhan
    RESULTS IN OPTICS, 2022, 9