Comparison of SPECT aerosol deposition data with twenty-four-hour clearance measurements

被引:11
作者
Fleming, John S.
Quint, Matthew
Bolt, Livia
Martonen, Ted B.
Conway, Joy H.
机构
[1] Southampton Univ Hosp NHS Trust, Dept Med Phys & Bioengn, Southampton, Hants, England
[2] St Marys Hosp, Dept Physiotherapy, Portsmouth PO3 6AQ, Hants, England
[3] US EPA, Natl Hlth & Environm Effects Res Lab, Expt Toxicol Div, Res Triangle Pk, NC USA
[4] Univ N Carolina, Dept Med, Chapel Hill, NC USA
[5] Univ Southampton, Sch Hlth Profess & Rehabil Sci, Southampton, Hants, England
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2006年 / 19卷 / 03期
关键词
aerosol deposition measurement; radionuclide imaging; twenty-four-hour clearance;
D O I
10.1089/jam.2006.19.261
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Three-dimensional (313) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data,can provide estimates of the deposition per airway generation. Information on regional distribution of deposited aerosol can also be obtained from 24-hour clearance measurements. In this study, a nebulizer was used to deliver a radiolabeled aerosol to nine human subjects. Single photon emission computed tomography (SPECT) has been used to assess the distribution of aerosol deposition per airway generation. The deposition pattern was also estimated using measurements of the aerosol remaining in the lung 24 h after inhalation. The error in the SPECT value was assessed by simulation and that in the 24-h clearance value by repeat analysis. The mean fraction of lung deposition in the conducting airway (CADF) from SPECT was 0.21. The corresponding 24-h clearance value was 0.23. These values were not significantly different. There was a weak but non-significant correlation between the SPECT and 24-h measurements (r = 0.49). The standard error of the difference was 0.11. The corresponding errors on the SPECT and 24-h clearance measurements were 0.04 and 0.05, respectively. There was no systematic difference between the values of conducting airways deposition obtained from 24-h measurements and SPECT. However, there were random differences on individual subjects, which were larger than the estimated measurement errors.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 14 条
  • [1] [Anonymous], 2021, ICRP DIGITAL WORKSHO
  • [2] MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM
    DEMPSTER, AP
    LAIRD, NM
    RUBIN, DB
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01): : 1 - 38
  • [3] Comparison of SPECT aerosol deposition data with a human respiratory tract model
    Fleming, John S.
    Epps, Ben P.
    Conway, Joy H.
    Martonen, Ted B.
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2006, 19 (03): : 268 - 278
  • [4] Evaluation of the accuracy and precision of lung aerosol deposition measurements from single-photon emission computed tomography using simulation
    Fleming, JS
    Sauret, V
    Conway, JH
    Holgate, ST
    Bailey, AG
    Martonen, TB
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2000, 13 (03): : 187 - 198
  • [5] Comparison of methods for deriving aerosol deposition by airway generation from three-dimensional radionuclide imaging
    Fleming, JS
    Conway, JH
    Holgate, ST
    Bailey, AG
    Martonen, TB
    [J]. JOURNAL OF AEROSOL SCIENCE, 2000, 31 (10) : 1251 - 1259
  • [6] DESCRIPTION OF PULMONARY DEPOSITION OF RADIOLABELED AEROSOL BY AIRWAY GENERATION USING A CONCEPTUAL 3-DIMENSIONAL MODEL OF LUNG MORPHOLOGY
    FLEMING, JS
    NASSIM, M
    HASHISH, AH
    BAILEY, AG
    CONWAY, J
    HOLGATE, S
    HALSON, P
    MOORE, E
    MARTONEN, TB
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (04): : 341 - 356
  • [7] Fleming JS, 2004, J AEROSOL MED, V17, P260
  • [8] A comparison of planar scintigraphy and SPECT measurement of total lung deposition of inhaled aerosol
    Fleming, JS
    Conway, JH
    Bolt, L
    Holgate, ST
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2003, 16 (01): : 9 - 19
  • [9] A GENERAL SOFTWARE PACKAGE FOR THE HANDLING OF MEDICAL IMAGES
    FLEMING, JS
    BRITTEN, AJ
    PERRING, S
    KEEN, AC
    HOWLETT, PJ
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1991, 15 (4-5) : 162 - 169
  • [10] Lung deposition of particles by airway generation in healthy subjects: Three-dimensional radionuclide imaging and numerical model prediction
    Hashish, AH
    Fleming, JS
    Conway, J
    Halson, P
    Moore, E
    Williams, TJ
    Bailey, AG
    Nassim, M
    Holgate, ST
    [J]. JOURNAL OF AEROSOL SCIENCE, 1998, 29 (1-2) : 205 - 215