Laser speckle contrast imaging and laser Doppler flowmetry reproducibly assess reflex cutaneous vasoconstriction

被引:8
作者
Schwartz, Kelsey S. [1 ]
Theis, Emma N. [1 ]
Bunting, Kearsten [2 ]
McCaughey, Rebecca A. [3 ]
Lang, James A. [1 ]
机构
[1] Iowa State Univ, Dept Kinesiol, 534 Wallace Rd, Ames, IA 50011 USA
[2] ICON, Clin Operat, Durham, NC USA
[3] Univ Iowa, Coll Pharm, Iowa City, IA 52242 USA
关键词
Microcirculation; Reliability; Coefficient of variation; Intraclass correlation; Skin blood flow; Whole-body cooling; MECHANISMS;
D O I
10.1016/j.mvr.2022.104363
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Reproducibility of the reflex cutaneous vasoconstriction response is currently unknown. Our aim was to determine the test-retest reproducibility of laser speckle contrast imaging (LSCI) and varying sampling depths of laser Doppler flowmetry (LDF) in response to whole-body cooling. Methods: Over two studies, nine and fourteen healthy, young adults underwent a 40-min cooling bout over two separate experiments. Participants were cooled from 34.0 degrees C to 30.5 degrees C and held at a 30.5 degrees C plateau for 10-min prior to rewarming. Throughout the cooling bout, changes in blood flow were measured as LSCI flux and LDF flux for Study 1 and LDF flux by three different LDF sampling depths in Study 2. Test-retest reproducibility and reliability were evaluated by the coefficient of variation (CV) and intraclass correlation coefficients (ICC), respectively. Vasoconstriction was presented as cutaneous vascular conductance (CVC = flux / mean arterial pressure) and expressed as a percent change from baseline (%Delta CVCBASELINE). Results: For Study 1, test-retest reproducibility displayed good reproducibility for LSCI (CV: < 9.0%) and good-to moderate for LDF (CV: < 17.0%) throughout the cooling bout and at plateau (LSCI CV: 1.0%; LDF CV: 1.9%). For Study 2, all Doppler depths displayed good reproducibility during the cooling bout (CV: < 9.0%) and at plateau (CV: 0.9-2.0%). Only LSCI demonstrated reliability across both studies (ICC: 0.58-0.88). A reduced vasoconstriction response was measured with the shallowest penetration in the skin (LSCI: 26 +/- 0.9%Delta CVCBASELINE) compared to the Doppler with the deepest penetration (35 +/- 0.6%Delta CVCBASELINE, p < 0.001). Conclusions: Although Dopplers better discriminate the reflex cutaneous vasoconstriction response, LSCI exhibits greater test-retest reproducibility and reliability, and thus may be more suitable for longitudinal assessments.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Laser reflectance oximetry and Doppler flowmetry in assessment of complex physiological parameters of cutaneous blood microcirculation
    Dunaev, Andrey V.
    Sidorov, Victor V.
    Stewart, Neil A.
    Sokolovski, Sergei G.
    Rafailov, Edik U.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [32] Myths and methodologies: Reliability of forearm cutaneous vasodilatation measured using laser-Doppler flowmetry during whole-body passive heating
    Gemae, Mohamed R.
    Akerman, Ashley P.
    McGarr, Gregory W.
    Meade, Robert D.
    Notley, Sean R.
    Schmidt, Madison D.
    Rutherford, Maura M.
    Kenny, Glen P.
    EXPERIMENTAL PHYSIOLOGY, 2021, 106 (03) : 634 - 652
  • [33] Strategies for reducing variance in laser Doppler flowmetry measurements
    Pemp, Berthold
    Maar, Noemi
    Weigert, Guenther
    Luksch, Alexandra
    Resch, Hemma
    Garhofer, Gerhard
    Orgul, Selim
    Schmetterer, Leopold
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (01) : 67 - 71
  • [34] Fractal dimensions of laser doppler flowmetry time series
    Carolan-Rees, G
    Tweddel, AC
    Naka, KK
    Griffith, TM
    MEDICAL ENGINEERING & PHYSICS, 2002, 24 (01) : 71 - 76
  • [35] EVALUATION OF GINGIVAL VASCULARISATION USING LASER DOPPLER FLOWMETRY
    Vitez, B.
    Todea, C.
    Velescu, A.
    Sipos, C.
    HIGH-END MEDICINE BASED ON LASER AND BIOTECHNOLOGIES, 2016, 9670
  • [36] LASER DOPPLER FLOWMETRY IN THE EVALUATION OF PERIODONTAL HEALTH AND DISEASE
    Firkova, Elena
    Bouka, Maria
    JOURNAL OF IMAB, 2019, 25 (03): : 2599 - 2602
  • [37] Laser speckle contrast imaging of the skin: interest in processing the perfusion data
    Anne Humeau-Heurtier
    Benjamin Buard
    Guillaume Mahe
    Pierre Abraham
    Medical & Biological Engineering & Computing, 2012, 50 : 103 - 105
  • [38] Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow
    Ambrus, Rikard
    Strandby, Rune B.
    Svendsen, Lars Bo
    Achiam, Michael P.
    Steffensen, John F.
    Svendsen, Morten Bo Sondergaard
    EUROPEAN SURGICAL RESEARCH, 2016, 56 (3-4) : 87 - 96
  • [39] Laser speckle contrast imaging of the skin: interest in processing the perfusion data
    Humeau-Heurtier, Anne
    Buard, Benjamin
    Mahe, Guillaume
    Abraham, Pierre
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 103 - 105
  • [40] Laser Doppler flowmetry - Experience in the intensive care unit
    Litscher, G
    Schwarz, G
    Dalageorgos, K
    Neger, J
    Kehl, G