Leak Localization in Water Networks A Model-Based Methodology Using Pressure Sensors Applied to a Real Network in Barcelona

被引:118
作者
Perez, Ramon
Sanz, Gerard
Puig, Vicenc
Quevedo, Joseba [1 ]
Angel, Miquel
Escofet, Cuguero
Nejjari, Fatiha
Meseguer, Jordi [2 ]
Cembrano, Gabriela [3 ,4 ]
Mirats Tur, Josep M. [5 ,6 ]
Sarrate, Ramon
机构
[1] Tech Univ Catalonia, Terrassa, Spain
[2] AGBAR Grp, Barcelona, Spain
[3] Inst Robot & Informat Ind CSIC UPC, Spanish Natl Res Council, Barcelona, Spain
[4] CETaqua Ctr Tecnol Agua Agbar CSIC UPC, Barcelona, Spain
[5] UNINA, Naples, Italy
[6] ITESM, Monterrey, Mexico
来源
IEEE CONTROL SYSTEMS MAGAZINE | 2014年 / 34卷 / 04期
关键词
INVERSE TRANSIENT ANALYSIS; PIPE SYSTEM DIAGNOSIS; UNSTEADY-STATE TESTS; CALIBRATION; MANAGEMENT;
D O I
10.1109/MCS.2014.2320336
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The efficient distribution of water is a subject of major concern for water utilities and authorities [1]. While some leaks in water distribution networks (WDNs) are unavoidable, one of the main challenges in improving the efficiency of drinking water networks is to minimize leaks. Leaks can cause significant economic losses in fluid transportation and extra costs for the final consumer due to the waste of energy and chemicals in water treatment plants. Leaks may also damage infrastructure and cause third-party damage and health risks. In many WDNs, losses due to leakage are estimated to account up to 30% of the total amount of extracted water [2]; a very important issue in a world struggling to satisfy water demands of a growing population. © 1991-2012 IEEE.
引用
收藏
页码:24 / 36
页数:13
相关论文
共 32 条
[11]  
Gertler J., 1998, Fault Detection and Diagnosis in Engineering Systems
[12]   A hybrid inverse transient model for leakage detection and roughness calibration in pipe networks [J].
Kapelan, ZS ;
Savic, DA ;
Walters, GA .
JOURNAL OF HYDRAULIC RESEARCH, 2003, 41 (05) :481-492
[13]  
LAMBERT A, 1994, J INST WATER ENV MAN, V8, P205
[14]  
Lambert AO, 2002, WA SCI TECHNOL, V2, P1
[15]   INVERSE TRANSIENT ANALYSIS IN PIPE NETWORKS [J].
LIGGETT, JA ;
CHEN, LC .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 1994, 120 (08) :934-955
[16]  
Mashford J, 2009, NSS: 2009 3RD INTERNATIONAL CONFERENCE ON NETWORK AND SYSTEM SECURITY, P534, DOI 10.1109/NSS.2009.38
[17]  
Meseguer J., J ENV MODEL IN PRESS
[18]   Wavenumber prediction of waves in buried pipes for water leak detection [J].
Muggleton, JM ;
Brennan, MJ ;
Pinnington, RJ .
JOURNAL OF SOUND AND VIBRATION, 2002, 249 (05) :939-954
[19]   Application of Predictive Control Strategies to the Management of Complex Networks in the Urban Water Cycle [J].
Ocampo-Martinez, Carlos ;
Puig, Vicenc ;
Cembrano, Gabriela ;
Quevedo, Joseba .
IEEE CONTROL SYSTEMS MAGAZINE, 2013, 33 (01) :15-41
[20]  