Bone stress for a mini-implant close to the roots of adjacent teeth-3D finite element analysis

被引:61
作者
Motoyoshi, M. [1 ]
Ueno, S. [1 ]
Okazaki, K. [1 ]
Shimizu, N. [1 ]
机构
[1] Nihon Univ, Sch Dent, Dept Orthodont, Div Clin Res,Dent Res Ctr,Chiyoda Ku, Tokyo 1018310, Japan
关键词
temporary anchorage devices; anchorage; finite element method; bone resorption; POSTERIOR REGION; PLACEMENT TORQUE; TITANIUM SCREWS; ANCHORAGE; THICKNESS; STABILITY; FAILURE;
D O I
10.1016/j.ijom.2009.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to evaluate stress in the bone when an orthodontic mini-implant is close to the roots of adjacent teeth using finite element models (FEMs), and to investigate the causes of the high implant failure rate in the mandible. Four FEMs were used: the implant touches nothing; the implant touches the surface of the periodontal membrane; part of the screw thread is embedded in the periodontal membrane; and the implant touches the root. The effect of cortical bone thickness was evaluated using values of 1, 2 and 3 mm. Maximum stress value and stress distribution on the bone elements was determined. Maximum stress on the bone increased when the mini-implant was close to the root. When the implant touched the root, stress increased to 140 MPa or more, and bone resorption could be predicted. Stress was higher for a cortical bone thickness of 2 mm than for other thicknesses. Cortical bone 2 mm thick had a higher risk for bone resorption. A mandible with an average cortical bone thickness of 2 mm may have a higher risk for implant loosening than a maxilla with the same degree of root proximity, which may be related to the lower success rate in the mandible.
引用
收藏
页码:363 / 368
页数:6
相关论文
共 28 条
[1]  
[Anonymous], 2001, ORTHOD WAVES
[2]  
Bae Seong-Min, 2002, J Clin Orthod, V36, P298
[3]  
Benzing U R, 1995, Int J Oral Maxillofac Implants, V10, P188
[4]  
Cheng SJ, 2004, INT J ORAL MAX IMPL, V19, P100
[5]  
Costa A, 1998, Int J Adult Orthodon Orthognath Surg, V13, P201
[6]   Bicortical titanium screws for critical orthodontic anchorage in the mandible: a preliminary report on clinical applications [J].
Freudenthaler, JW ;
Haas, R ;
Bantleon, HP .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (04) :358-363
[7]   Mini-implant anchorage for maxillary canine retraction: A pilot study [J].
Herman, Robert J. ;
Currier, G. Frans ;
Miyake, Alan .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (02) :228-235
[8]  
Hirabayashi Masayuki, 2002, J Oral Sci, V44, P1
[9]  
Holmgren E P, 1998, J Oral Implantol, V24, P80, DOI 10.1563/1548-1336(1998)024<0080:EPOODI>2.3.CO
[10]  
2